Skip to main content
Draeger detector tubes · Vinyl chloride

Draeger Vinyl Chloride Detector Tubes

2 Draeger short-term detector tubes for Vinyl chloride, measuring ranges from 5 to 30 ppm / 0.5 to 5 ppm up to 100 to 3000 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (pp. 274–275). Ships in 1–2 business days.

Every Draeger tube for Vinyl chloride

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
8101721Draeger Vinyl Chloride 0.5/b Detector Tubes, Box of 105 to 30 ppm / 0.5 to 5 ppm1 /5approx. 30 s / approx. 2.5 minwhite → purpleBox of 10$144.12
CH19601Draeger Vinyl Chloride 100/a Detector Tubes, Box of 10100 to 3000 ppm18 to 1max. 3 minpurple → light brownBox of 10$151.74

Two ranges on one tube? The range depends on the number of pump strokes. How pump strokes set the range on a Draeger tube.

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), pp. 274–275, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Vinyl chloride exposure limits

LimitValue
OSHA PEL[1910.1017] TWA 1 ppm C 5 ppm [15-minute]
NIOSH RELCa
NIOSH IDLHCa [N.D.]
CAS number75-01-4
FormulaCH₂=CHCl
Other namesChloroethene, Chloroethylene, Ethylene monochloride, Monochloroethene, Monochloroethylene, VC, VCM, Vinyl chloride monomer (VCM)
Conversion1 ppm = 2.56 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Vinyl chloride (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless gas or liquid (below 7°F) with a pleasant odor at high concentrations. [Note: Shipped as a liquefied compressed gas.]

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Vinyl chloride tube questions

Which Draeger tubes measure Vinyl chloride? 8101721 (5 to 30 ppm / 0.5 to 5 ppm), CH19601 (100 to 3000 ppm).

What is the lowest range Draeger tube for Vinyl chloride? 8101721, 5 to 30 ppm / 0.5 to 5 ppm, 1 /5 strokes.

What is the OSHA exposure limit for Vinyl chloride? OSHA PEL [1910.1017] TWA 1 ppm C 5 ppm [15-minute]; NIOSH REL Ca; IDLH Ca [N.D.] (NIOSH Pocket Guide).

Which pump reads Draeger Vinyl chloride tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Vinyl chloride tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

The ratings, test results and standards shown here are the manufacturers' published values, reproduced as published. Nothing on this page is a recommendation by Bayshore Safety that any product is suitable for a particular task, hazard or workplace. Selecting safety products and protective equipment is the responsibility of the end user and the employer, based on their own hazard assessment and the regulations that apply to their work. Confirm every value on the manufacturer's own documentation before use.

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.