Description
Draeger Nitrogen Dioxide detector tubes measure nitrogen dioxide in air with a simple color-change reading, no power or calibration needed. They are a common spot-check tool for diesel exhaust, welding and blasting fumes. Pick the measuring range that fits the job; each tube works with the Draeger accuro or other Draeger tube pumps.
- Ranges available: 0.1-30 ppm (0.1/a), 2-100 ppm (2/c)
- Works with the Draeger accuro and other Draeger tube pumps
- Box of 10 single-use tubes, one measurement per tube
- Color change read directly against the printed scale on the tube
- See the instruction sheet in each box for pump strokes and cross-sensitivities
Draeger part number: select an option to see the exact part number.
Available in 2 versions:
- 0.1-30 ppm (0.1/a) – 8103631
- 2-100 ppm (2/c) – 6719101
Specifications
Gases detected: Nitrogen dioxide
Measuring range: 0.1-30 ppm; 2-100 ppm
Style: Short-term detector tube
Capacity: 10 tubes per box