Skip to main content

Multi-Gas Detectors

Four- and five-gas monitors (O2, LEL, H2S, CO and more) from RKI Instruments, Honeywell BW and MSA: the GX-3R, GX-3R Pro, GX-Force, BW Clip4, MicroClip and ALTAIR series. Diffusion and pumped versions are both here; use the configurator to build an RKI to your exact gas list.

In this category

413 products from RKI Instruments, BW Technologies / Honeywell Analytics, MSA, Industrial Scientific. Gases Detected: LEL (252), O2 (86), H2S (34), CO (26), Combustible Gas (LEL) (15). Number of Gases: 3 (134), 4 (127), 2 (117), 5 (25), 1 (2). Sample Method: Diffusion (373), Pump (sample draw) (32). Battery: Li-Ion (168), Alkaline (76), Alkaline & Li-Ion (73), Rechargeable Li-Ion (18). Sold individually (75).

Brands in this category: RKI Instruments (317) · BW Technologies / Honeywell Analytics (61) · MSA (29) · Industrial Scientific (6)

How to read a gas monitor specification

A gas monitor lists the gases it detects, the sensor type and the measuring range for each (for example 0 to 100% LEL for combustibles, 0 to 25% volume for oxygen, 0 to 100 ppm for H2S), its alarm set points, battery run time, and intrinsic safety approvals (UL or CSA Class I Division 1 marks). Calibration gas and bump-test schedules follow the manufacturer's manual.

What the rules say about multi-gas detectors

OSHA 1910.146 Permit-Required Confined Spaces: what it requires and the equipment it names: 29 CFR 1910.146 requires an employer whose workplace contains permit-required confined spaces to post danger signs, decide whether employees will enter, and if so run a written permit space program: test the atmosphere with a calibrated direct-reading instrument for oxygen, then flammable gases and vapors, then toxic air contaminants, keep the space within acceptable entry conditions, post an attendant, provide retrieval systems for non-entry rescue, and arrange rescue services that can respond in time. OSHA 1910.1000 Air Contaminants: what it requires and the equipment it names: 29 CFR 1910.1000 requires an employer to limit each employee's exposure to the substances in Table Z-1 (most gases, vapors and dusts), Z-2 (a short list of older substances with ceiling and peak values) and Z-3 (mineral dusts) to the 8-hour time-weighted average, the ceiling (C) value that is never to be exceeded, or the acceptable maximum peak listed, computed as the paragraph (d) formulas set out. OSHA 1926 Subpart AA Confined Spaces in Construction (1926.1203): what it requires and the equipment it names: 29 CFR 1926.1203 requires each construction employer to have a competent person identify all confined spaces its employees may work in and each one that is a permit space, through consideration, evaluation and testing as necessary; to inform exposed employees and the controlling contractor of each permit space; and, if employees will enter, to follow a written permit space program under 1926.1204 or the alternate procedures of 1926.1203(e) where continuous forced air ventilation alone controls the only hazard, with the atmosphere tested before entry with a calibrated direct-reading instrument for oxygen, then flammables, then toxics, and monitored periodically. Every rule page lists the equipment the rule names with the products we carry for it; the safety rules index has them all.

Guides for multi-gas detectors

Gas detection for confined space entry: what to test and the order · Gas detector for landfills and wastewater: methane, H2S and oxygen, and which monitors fit the work · Intrinsically safe gas detectors: what Class I Div 1 and Div 2 mean · Single-gas vs multi-gas detectors: which does the job need? · Confined spaces in construction: how 1926 Subpart AA differs from 1910.146 · Gas monitors for welding and hot work: what to measure

Ratings and specifications on this page are shown as published by the manufacturer or the named standard and describe performance in that standard's test. They are not a recommendation for any task. The employer's hazard assessment decides what protective equipment a job needs. Verify details against the manufacturer's current documentation before you buy.

RKI Instruments series

Honeywell BW series

MSA series

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.