Skip to main content
MSA

MSA 10154079 ALTAIR 2X Ammonia Detector, 25/50 ppm Alarms, 2X

Item # 10154079
Regular price: $1,177.00
$1,118.15
(You save $58.85 )

MSA 10154079 is the MSA ALTAIR 2X single-gas monitor configured for ammonia (NH3). MSA prints it as "ALTAIR 2X, NH3 (25, 50), Charcoal". Alarm set points as printed: NH3 25, 50. Weight 4 oz (113 g) with clip; ingress protection IP67; drop protection 25 feet; warranty 3 years (2 years on the Cl2 and NH3 sensors), as MSA lists them for the ALTAIR 2X. Charcoal housing. Sold individually. Ships in 1–2 business days; most orders arrive in 3–7 business days.

MSA 10154079 specifications

ItemMSA data
Part number10154079
ModelMSA ALTAIR 2X
Gases detectedNH3
Number of gases1
SamplingDiffusion
Alarm set points (as printed)NH3: 25, 50
Size3.5 in L x 2.125 in W x 1.25 in D (no clip)
Weight4 oz (113 g) with clip
HousingRugged rubberized armor
Ingress protectionIP67
Drop test25 feet
AlarmsAudible 95 dB at 1 foot; ultra-bright LEDs; vibrating alarm standard
DisplayLarge-character monochrome LCD, 10 s backlight with adjustable timeout
Battery and run timeReplaceable lithium battery
Operating temperatureExtended range -20 °C to +50 °C; extreme range -40 °C to +60 °C
Datalogging2X / 2XP: more than 950 hours at the default interval; 2XT: more than 850 hours; event log 300+ events
Bump testPass: green LED flash and checkmark; fail or expiration: red LED flash only
WarrantyChassis and electronics 3 years; Cl2 and NH3 sensors 2 years; all other sensors 3 years (does not cover consumable parts)

Source: MSA product page https://us.msasafety.com/Portable-Gas-Detection/Single-or-Two-Gas/ALTAIR%C2%AE-2X-Gas-Detector/p/000080000200001600, fetched Nov 10 2026; Bulletin: ALTAIR 2X Gas Detectors (PDF); MSA ALTAIR 2X Gas Detectors bulletin 0802-96-MC (PDF). Figures are as the manufacturer publishes them for the model; the part number sets the sensors and kit contents.

Gases and ranges on the 10154079

GasRange and resolution (as printed)
ammonia (NH3)0-100 ppm

Source: MSA product page https://us.msasafety.com/Portable-Gas-Detection/Single-or-Two-Gas/ALTAIR%C2%AE-2X-Gas-Detector/p/000080000200001600, fetched Nov 10 2026 (sensor range table); MSA ALTAIR 2X Gas Detectors bulletin 0802-96-MC (PDF). The ranges are the model's sensor ranges; alarm set points are the factory settings and are user adjustable where the manual says so.

Exposure limits for the gases the 10154079 detects

GasCASOSHA PELNIOSH RELNIOSH IDLH
Ammonia (NH3)7664-41-7TWA 50 ppm (35 mg/m³)TWA 25 ppm (18 mg/m³) ST 35 ppm (27 mg/m³)300 ppm

Source: NIOSH Pocket Guide to Chemical Hazards (OSHA PEL, NIOSH REL and IDLH, CAS number, as published); 29 CFR 1910.146(b) for the oxygen and flammable-gas definitions. Limits are the published figures, not a recommendation for any task.

Approvals and standards, as printed

MarkAs the manufacturer prints it
USAcCSAus Class I Div 1 Groups A, B, C, D; Class II Div 1 Groups E, F, G; Class III; Tamb = -40 °C to +60 °C T4; UL 913 7th Edition
CanadaCSA 22.2 No. 157
ATEXFTZU II 2G Ex ia IIC T4 Gb, -40 °C to +60 °C
IEC / Australia / New ZealandFTZU Ex ia IIC T4 Gb, -40 °C to +60 °C

Source: MSA product page https://us.msasafety.com/Portable-Gas-Detection/Single-or-Two-Gas/ALTAIR%C2%AE-2X-Gas-Detector/p/000080000200001600, fetched Nov 10 2026; MSA ALTAIR 2X Gas Detectors bulletin 0802-96-MC (PDF) (certifications). Approvals are as published by the manufacturer for the model and may differ by configuration and part number; the label on the instrument governs.

ALTAIR 2X features, as MSA lists them

  • XCell Pulse Technology on the ALTAIR 2XP: a stand-alone bump test with no bottled gas or accessories (pulse check then an exhaled-breath flow check)
  • XCell Two-Tox sensors on the ALTAIR 2XT detect two gases on distinct sensor channels with digital output
  • One-button, gloved-hand operation
  • End-of-sensor-life indicator
  • Green LED and check mark when bumped; red LED when not bump tested
  • Full instrument traceability of bump and calibration records, peak readings, event logs and data logs; records download through the GALAXY GX2 test stand
  • MSA states XCell sensors have a typical life of more than four years

Source: MSA product page https://us.msasafety.com/Portable-Gas-Detection/Single-or-Two-Gas/ALTAIR%C2%AE-2X-Gas-Detector/p/000080000200001600, fetched Nov 10 2026; MSA ALTAIR 2X Gas Detectors bulletin 0802-96-MC (PDF)

What you get

One MSA ALTAIR 2X monitor configured for NH3. MSA lists the kit contents against the part number in the ordering table of the bulletin linked below. Price shown is for one unit.

Related ALTAIR 2X part numbers

Part numberConfigurationPriceListing
10154079NH3 · 2X · charcoal$1118.15this page
10153984H2S · 2XP · charcoal$716.30MSA 10153984 ALTAIR 2X H2S Monitor, 10/15 ppm Alarms, 2XP
10154080Cl2 · 2X · charcoal$1118.15MSA 10154080 ALTAIR 2X Chlorine Gas Detector, 0.5/1 ppm Alarms, 2X
10153986CO · 2X · charcoal$635.55MSA 10153986 ALTAIR 2X Portable CO Monitor, 25/100 ppm Alarms, 2X
10154073CO/NO2 · 2XT · charcoal$836.00MSA 10154073 ALTAIR 2X 2-Gas Monitor, CO/NO2, 2XT
10154078NO2 · 2X · charcoal$814.15MSA 10154078 ALTAIR 2X NO2 Detector, 2.5/5 ppm Alarms, 2X
10154077SO2 · 2X · charcoal$814.15MSA 10154077 ALTAIR 2X SO2 Detector, 2/5 ppm Alarms, 2X
10153985H2S/SO2 · 2XT · charcoal$836.00MSA 10153985 ALTAIR 2X 2-Gas Monitor, H2S/SO2, 2XT
10154040H2S/CO · 2XT · charcoal$836.00MSA 10154040 ALTAIR 2X 2-Gas Monitor, H2S/CO, 2XT

Every ALTAIR 2X listing we stock is on the MSA ALTAIR 2X Single-Gas and Two-Tox Detectors page.

Source: Configurations as the manufacturer prints them per part number; prices from the store.

MSA 10154079 questions

What gases does the 10154079 detect? Ammonia (NH3). It is the MSA ALTAIR 2X configured with one sensor; MSA lists the range for each in the table above.

How often do gas monitors need to be calibrated? MSA publishes the bump and calibration procedure in the ALTAIR 2X manual linked below. The ALTAIR 2XP runs a stand-alone bump test (pulse check plus an exhaled-breath flow check) with no bottled gas; every ALTAIR 2X model also docks in the GALAXY GX2 test stand for calibration.

How long does the 10154079 run on a charge or battery? MSA lists: Replaceable lithium battery.

Is the 10154079 intrinsically safe, and what approvals does it carry? The markings MSA prints are: cCSAus Class I Div 1 Groups A, B, C, D; Class II Div 1 Groups E, F, G; Class III; Tamb = -40 °C to +60 °C T4; UL 913 7th Edition; CSA 22.2 No. 157; FTZU II 2G Ex ia IIC T4 Gb, -40 °C to +60 °C. A Class I, Division 1 or Ex ia marking is the approval for the hazardous location it names; read the marking on the instrument label for the configuration you buy.

What is the warranty on the 10154079? Chassis and electronics 3 years; Cl2 and NH3 sensors 2 years; all other sensors 3 years (does not cover consumable parts), as MSA states.

How long do the XCell sensors in the 10154079 last? MSA states XCell sensors have a typical life of more than four years and lists a 3-year warranty on the instrument and most sensors (2 years on Cl2 and NH3).

Guides: single-gas vs multi-gas · bump test vs calibration · how to read a gas monitor alarm · what Class I Div 1 means · ATEX vs intrinsically safe · sensor life · gas detection records · every gas monitor by gas, sampling and battery.

MSA ALTAIR 2X documents

Source: MSA product page https://us.msasafety.com/Portable-Gas-Detection/Single-or-Two-Gas/ALTAIR%C2%AE-2X-Gas-Detector/p/000080000200001600, fetched Nov 10 2026 (documents list).

Usually ships in 1–2 business days; delivery in 3–7 business days.

Adding to cart… The item has been added
Sold by the Each
Specifications
Product TypeGas Monitor
ModelALTAIR 2X
Gases DetectedNH3
Number of Gases1
Sample MethodDiffusion
Sensor RangesNH3 0-100 ppm
StandardsCSA Class I Div 1 Groups A, B, C, D; ATEX; IECEx
Ingress ProtectionIP67
Warranty3 years (2 years on the Cl2 and NH3 sensors)
BatteryReplaceable lithium battery
IncludesMonitor only
Shipping Weight0.243 LB
Shipping Package2.4 x 2.1 x 3.5 in (W x L x H)
Battery LifeNon-rechargeable 3.6 V lithium battery, 6 to 18 months depending on settings and use
Shipping & returns

In-stock orders: 1–2 business days to process, then 2–5 business days by ground (3–7 in all); regular rates apply and Contractor Direct orders ship free. Most items can be returned within 30 days in new, resalable condition; respirators, filters and other hygiene items are final sale. Shipping policy · Returns policy

MSA 10154079 ALTAIR 2X Ammonia Detector, 25/50 ppm Alarms, 2X$1,118.15

More MSA and other brands in this category

Reviews

No reviews yet. Used this on the job? Tell other crews how it held up.

Write a review ›
How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.