Description
MSA 10255039 is the MSA ALTAIR io 6 5-gas pumped gas monitor with a built-in sampling pump configured for combustible gas (LEL), oxygen (O2), hydrogen sulfide (H2S), carbon monoxide (CO) and sulfur dioxide (SO2). MSA prints it as "ALTAIR io 6 Multigas Detector, Purchase, NA/IEC/ATEX, LEL 0-100%, O2 0-30% vol, CO std, H2S std, SO2 std, Charger NA/EU/UK". Weight 0.9 lb (14.4 oz); ingress protection IP65; drop protection exceeds 26 drops from 4 ft; warranty 4 years (outright purchase), as MSA lists them for the ALTAIR io 6. Ships with the NA/EU/UK charger. Sold individually. Ships in 1–2 business days; most orders arrive in 3–7 business days.
MSA 10255039 specifications
| Item | MSA data |
|---|---|
| Part number | 10255039 |
| Model | MSA ALTAIR io 6 |
| Gases detected | LEL, O2, H2S, CO, SO2 |
| Number of gases | 5 |
| Sampling | Pump (sample draw) |
| Size | 5.90 x 3.23 x 2.24 in (14.98 x 8.20 x 5.69 cm) |
| Weight | 0.9 lb (14.4 oz) |
| Ingress protection | IP65 |
| Drop test | Exceeds 26 drops from 4 ft (1.2 m) (MIL-STD-810G 516.6 transit drop); capable of surviving an incidental 10 ft (3 m) drop onto concrete; survives 60 minutes in the NFPA 1982-2018 tumble tester |
| Display | Large high-visibility screen |
| Battery and run time | Removable and rechargeable; typical full charge 6.5 hours at room temperature; charging temperature 32 °F to 104 °F (0 °C to 40 °C); battery life 16 hours typical, 13 hours with the PID sensor |
| Datalogging | Minimum 90-day cloud-synced data logs; device data synced and stored in the customer Grid account |
| Warranty | 4 year warranty with outright purchase; always under warranty with subscription (as MSA states; subscription only in selected locations and excludes certain sensors) |
Source: MSA product page https://us.msasafety.com/Portable-Gas-Detection/Multi-Gas/ALTAIR-io%E2%84%A2-6-Multigas-Detector/p/000170000800008006; Bulletin: ALTAIR io 6 Multigas Detector (PDF); MSA ALTAIR io 6 Multigas Detector specifications 1708-116-MC (PDF). Figures are as the manufacturer publishes them for the model; the part number sets the sensors and kit contents.
Gases and ranges on the 10255039
| Gas | Range and resolution (as printed) |
|---|---|
| combustible gas (LEL) | 0-100% LEL or 0-5% vol CH4, catalytic, sensor life 5 years |
| oxygen (O2) | 0-30% vol, electrochemical, 7 years |
| hydrogen sulfide (H2S) | 0-200 ppm, electrochemical, 7 years; H2S low concentration 0-100 ppm |
| carbon monoxide (CO) | 0-2000 ppm, electrochemical, 7 years; CO hydrogen-resistant 0-1999 ppm |
| sulfur dioxide (SO2) | 0-20 ppm, electrochemical, 7 years |
Source: MSA product page https://us.msasafety.com/Portable-Gas-Detection/Multi-Gas/ALTAIR-io%E2%84%A2-6-Multigas-Detector/p/000170000800008006 (sensor range table); MSA ALTAIR io 6 Multigas Detector specifications 1708-116-MC (PDF). The ranges are the model's sensor ranges; alarm set points are the factory settings and are user adjustable where the manual says so.
Exposure limits for the gases the 10255039 detects
| Gas | CAS | OSHA PEL | NIOSH REL | NIOSH IDLH |
|---|---|---|---|---|
| Hydrogen sulfide (H2S) | 7783-06-4 | C 20 ppm 50 ppm [10-minute maximum peak] | C 10 ppm (15 mg/m³) [10-minute] | 100 ppm |
| Carbon monoxide (CO) | 630-08-0 | TWA 50 ppm (55 mg/m³) | TWA 35 ppm (40 mg/m³) C 200 ppm (229 mg/m³) | 1200 ppm |
| Sulfur dioxide (SO2) | 7446-09-5 | TWA 5 ppm (13 mg/m³) | TWA 2 ppm (5 mg/m³) ST 5 ppm (13 mg/m³) | 100 ppm |
29 CFR 1910.146(b) defines a hazardous atmosphere to include a flammable gas, vapor or mist in excess of 10 percent of its lower flammable limit (LFL), an atmospheric oxygen concentration below 19.5 percent or above 23.5 percent, and any atmospheric concentration of a substance that could result in employee exposure in excess of its dose or permissible exposure limit.
Source: NIOSH Pocket Guide to Chemical Hazards (OSHA PEL, NIOSH REL and IDLH, CAS number, as published); 29 CFR 1910.146(b) for the oxygen and flammable-gas definitions. Limits are the published figures, not a recommendation for any task.
Approvals and standards, as printed
| Mark | As the manufacturer prints it |
|---|---|
| USA / Canada | FCC and Industry Canada; CSA; Class I, Division 1, Groups A, B, C and D T4, -20 °C to +55 °C; Class I, Zone 0, AEx da ia IIC Ga T4 |
Source: MSA product page https://us.msasafety.com/Portable-Gas-Detection/Multi-Gas/ALTAIR-io%E2%84%A2-6-Multigas-Detector/p/000170000800008006; MSA ALTAIR io 6 Multigas Detector specifications 1708-116-MC (PDF) (certifications). Approvals are as published by the manufacturer for the model and may differ by configuration and part number; the label on the instrument governs.
ALTAIR io 6 features, as MSA lists them
- Built-in pump and 6-gas capability
- Out-of-box connectivity to the MSA Grid; cellular LTE-M (Eseye AnyNet connectivity); Bluetooth v4.1 Low Energy
- Concurrent GNSS (GPS, GLONASS and Galileo) with assisted GNSS; GPS accuracy 8 ft (2.5 m) as MSA states
- RFID reader for MSA id Tags and dock communication
- Easy serviceability: removable battery pack, inlet filter and sample probe filter
Source: MSA product page https://us.msasafety.com/Portable-Gas-Detection/Multi-Gas/ALTAIR-io%E2%84%A2-6-Multigas-Detector/p/000170000800008006; MSA ALTAIR io 6 Multigas Detector specifications 1708-116-MC (PDF)
What you get
One MSA ALTAIR io 6 monitor configured for LEL/O2/H2S/CO/SO2. MSA lists the kit contents against the part number in the ordering table of the bulletin linked below. Price shown is for one unit.
Related ALTAIR io 6 part numbers
| Part number | Configuration | Price | Listing |
|---|---|---|---|
| 10255039 | LEL/O2/H2S/CO/SO2 | $4151.78 | this page |
| 10245598 | LEL/O2/H2S/CO | $1595.24 | MSA 10245598 ALTAIR io 4 4-Gas Monitor, LEL/O2/H2S/CO |
| 10255038 | LEL/O2/H2S/CO | $3188.67 | MSA 10255038 ALTAIR io 6 4-Gas Monitor, LEL/O2/H2S/CO |
| 10255041 | LEL/O2/H2S/CO/NH3 | $4151.78 | MSA 10255041 ALTAIR io 6 5-Gas Monitor, LEL/O2/H2S/CO/NH3 |
| 10255040 | LEL/O2/H2S/CO/Cl2 | $4151.78 | MSA 10255040 ALTAIR io 6 5-Gas Monitor, LEL/O2/H2S/CO/Cl2 |
| 10255042 | LEL/O2/H2S/CO/NO2 | $4151.78 | MSA 10255042 ALTAIR io 6 5-Gas Monitor, LEL/O2/H2S/CO/NO2 |
Every ALTAIR io 6 listing we stock is on the MSA ALTAIR io 4 and io 6 Connected Gas Detectors page.
Source: Configurations as the manufacturer prints them per part number; prices from the store.
MSA 10255039 questions
What gases does the 10255039 detect? Combustible gas (LEL), oxygen (O2), hydrogen sulfide (H2S), carbon monoxide (CO) and sulfur dioxide (SO2). It is the MSA ALTAIR io 6 configured with 5 sensors; MSA lists the range for each in the table above.
How often do gas monitors need to be calibrated? MSA publishes the bump and calibration procedure in the ALTAIR io 6 manual linked below. The ALTAIR io 6 runs its bump test in the ALTAIR io Dock, which sends the compliance record to your MSA Grid account.
How long does the 10255039 run on a charge or battery? MSA lists: Removable and rechargeable; typical full charge 6.5 hours at room temperature; charging temperature 32 °F to 104 °F (0 °C to 40 °C); battery life 16 hours typical, 13 hours with the PID sensor.
Is the 10255039 intrinsically safe, and what approvals does it carry? The markings MSA prints are: FCC and Industry Canada; CSA; Class I, Division 1, Groups A, B, C and D T4, -20 °C to +55 °C; Class I, Zone 0, AEx da ia IIC Ga T4. A Class I, Division 1 or Ex ia marking is the approval for the hazardous location it names; read the marking on the instrument label for the configuration you buy.
What is the warranty on the 10255039? 4 year warranty with outright purchase; always under warranty with subscription (as MSA states; subscription only in selected locations and excludes certain sensors), as MSA states.
How long do the XCell sensors in the 10255039 last? MSA lists a typical sensor life of 5 years for the catalytic LEL sensor, 7 years for O2, CO, H2S, SO2 and NO2, 4 years for Cl2 and NH3 and 3 years for the PID.
Guides: what a 4-gas monitor measures · what LEL means · oxygen deficiency and enrichment · H2S exposure limits · CO exposure limit · confined space gas testing order · bump test vs calibration · every gas monitor by gas, sampling and battery.
MSA ALTAIR io 6 documents
- Bulletin: ALTAIR io 6 Multigas Detector (PDF)
- Technical Bulletin: ALTAIR 2X, 4XR & 5X Gas Detectors & ALTAIR io 4 Gas Detection Wearable & ALTAIR io 6 Multigas Detector Electrochemical Sensor Cross-Sensitivity Data (PDF)
- Technical Specifications: ALTAIR io 6 Multigas Detector (PDF)
- IEC 61010-1: ALTAIR io 6 (PDF)
- CSA: ALTAIR io 6 (PDF)
Source: MSA product page https://us.msasafety.com/Portable-Gas-Detection/Multi-Gas/ALTAIR-io%E2%84%A2-6-Multigas-Detector/p/000170000800008006 (documents list).