BW Technologies MCX3-XW0M-Y-NA is the Honeywell BW MicroClip X3 3-gas personal gas monitor configured for combustible gas (LEL), oxygen (O2) and carbon monoxide (CO). Honeywell BW prints it as "GasAlert MicroClip X3 LEL(F) O2 CO (R,Y,NA)". Weight 6.7 oz / 190 g; battery 18 hours; recharges in less than 6 hours hours; ingress protection IP68; warranty 2 years on honeywell bw microclip xl, as Honeywell lists them for the MicroClip X3. Yellow housing. Sold individually. Ships in 1–2 business days; most orders arrive in 3–7 business days.
BW Technologies MCX3-XW0M-Y-NA specifications
| Item | Honeywell BW data |
|---|---|
| Part number | MCX3-XW0M-Y-NA |
| Model | Honeywell BW MicroClip X3 |
| Gases detected | LEL, O2, CO |
| Number of gases | 3 |
| Sampling | Diffusion |
| Instrument size | 11.3 x 6.0 x 3.2 cm / 4.4 x 2.4 x 1.2 in |
| Weight | 6.7 oz / 190 g |
| Alarm type | Audible; Vibrating; Visual |
| Alarm loudness | 95 decibel |
| Display | LCD |
| Battery | Yes |
| Battery run time | 18 Hours; Recharges in Less than 6 Hours hours |
| Charging time | 6 hours |
| Datalogging | 16 hours at 15-second intervals |
| Operating temperature (minimum) | -4 °F / -20 °C |
| Operating temperature (maximum) | 122 °F / 50 °C |
| Humidity | 0 to 95% RH (Non-Condensing) percent; 0%-95% percent |
| Ingress protection | IP68 |
| Sensor life | 5 Years |
| Wireless | BLE |
| Docking and calibration | Compatible with IntelliDox Docking Station for Automated Bump Tests and Calibration |
| Languages | English, French, German, Spanish, Portuguese |
| Warranty | 2 Years on Honeywell BW MicroClip XL; 3 Years on Honeywell BW MicroClip X3 |
Source: Honeywell BW product page https://automation.honeywell.com/us/en/products/gas-and-flame-detection/portables/multi-gas/honeywell-bw-microclip-series-multi-gas-detector; Honeywell BW MicroClip Series Data Sheet (PDF). Figures are as the manufacturer publishes them for the model; the part number sets the sensors and kit contents.
Gases and ranges on the MCX3-XW0M-Y-NA
| Gas | Range (as printed) | Resolution |
|---|---|---|
| combustible gas (LEL) | 0-100% and 0-5.0% v/v | 1% |
| oxygen (O2) | 0 to 30.0% | 0.1% |
| carbon monoxide (CO) | 0-500 ppm | 1 ppm |
Source: Honeywell BW product page https://automation.honeywell.com/us/en/products/gas-and-flame-detection/portables/multi-gas/honeywell-bw-microclip-series-multi-gas-detector (sensor range table). The ranges are the model's sensor ranges; alarm set points are the factory settings and are user adjustable where the manual says so.
Exposure limits for the gases the MCX3-XW0M-Y-NA detects
| Gas | CAS | OSHA PEL | NIOSH REL | NIOSH IDLH |
|---|---|---|---|---|
| Carbon monoxide (CO) | 630-08-0 | TWA 50 ppm (55 mg/m³) | TWA 35 ppm (40 mg/m³) C 200 ppm (229 mg/m³) | 1200 ppm |
29 CFR 1910.146(b) defines a hazardous atmosphere to include a flammable gas, vapor or mist in excess of 10 percent of its lower flammable limit (LFL), an atmospheric oxygen concentration below 19.5 percent or above 23.5 percent, and any atmospheric concentration of a substance that could result in employee exposure in excess of its dose or permissible exposure limit.
Source: NIOSH Pocket Guide to Chemical Hazards (OSHA PEL, NIOSH REL and IDLH, CAS number, as published); 29 CFR 1910.146(b) for the oxygen and flammable-gas definitions. Limits are the published figures, not a recommendation for any task.
Approvals and standards, as printed
| Mark | As the manufacturer prints it |
|---|---|
| Approvals and standards (as listed) | ATEX: CE II 1 G. Ex ia IIC T4 Ga |
| Approvals and standards (as listed) | CE European Conformity |
| Approvals and standards (as listed) | CSA: Class I, Div 1, Group A, B, C, D |
| Approvals and standards (as listed) | IECEx: Ex ia IIC T4 Ga |
Source: Honeywell BW product page https://automation.honeywell.com/us/en/products/gas-and-flame-detection/portables/multi-gas/honeywell-bw-microclip-series-multi-gas-detector (standards rows). Approvals are as published by the manufacturer for the model and may differ by configuration and part number; the label on the instrument governs.
MicroClip X3 features, as Honeywell BW lists them
- Compatible with Honeywell BW Connect for Real Time Monitoring
- Device Management with Honeywell SafetySuite
- Durable, Rechargeable Lithium Polymer Battery Tested to Last in Extreme Environments
- Ergonomic and Wearable Doesn't Weigh You Down
- Guaranteed Runtime for at Least a 12-Hour Shift, Down To -20°C without Compromising LEL Detection of Hydrogen, Acetylene and Other Combustible Gases
- IntelliFlash Light Indicating Detector has Been Bump Tested and is Monitoring Correctly
- User-Friendly Tamperproof Operation with Just One Button and Intuitive LCD Icons
Source: Honeywell BW product page https://automation.honeywell.com/us/en/products/gas-and-flame-detection/portables/multi-gas/honeywell-bw-microclip-series-multi-gas-detector
What you get
One Honeywell BW MicroClip X3 monitor configured for LEL/O2/CO. Honeywell lists the standard contents in the user manual linked below. Price shown is for one unit.
Related MicroClip X3 part numbers
Every MicroClip X3 listing we stock is on the Honeywell BW MicroClip XL and X3 Gas Monitors page.
Source: Configurations as the manufacturer prints them per part number; prices from the store.
BW Technologies MCX3-XW0M-Y-NA questions
What gases does the MCX3-XW0M-Y-NA detect? Combustible gas (LEL), oxygen (O2) and carbon monoxide (CO). It is the Honeywell BW MicroClip X3 configured with 3 sensors; Honeywell BW lists the range for each in the table above.
How often do gas monitors need to be calibrated? Honeywell publishes the bump test and calibration intervals in the MicroClip X3 user manual linked below; the monitor can force a bump test or calibration when overdue where that option is listed. The MicroClip X3 is compatible with the IntelliDoX docking station for automated bump tests and calibration, as Honeywell lists it.
How long does the MCX3-XW0M-Y-NA run on a charge or battery? Honeywell BW lists 18 Hours; Recharges in Less than 6 Hours hours; charging time 6 hours.
Is the MCX3-XW0M-Y-NA intrinsically safe, and what approvals does it carry? The markings Honeywell BW prints are: ATEX: CE II 1 G. Ex ia IIC T4 Ga; CE European Conformity; CSA: Class I, Div 1, Group A, B, C, D. A Class I, Division 1 or Ex ia marking is the approval for the hazardous location it names; read the marking on the instrument label for the configuration you buy.
What is the warranty on the MCX3-XW0M-Y-NA? 2 Years on Honeywell BW MicroClip XL; 3 Years on Honeywell BW MicroClip X3, as Honeywell BW states.
How long do the sensors in the MCX3-XW0M-Y-NA last? Honeywell BW lists a sensor life of 5 Years.
Guides: what LEL means · oxygen deficiency and enrichment · CO exposure limit · confined space gas testing order · bump test vs calibration · how to read a gas monitor alarm · what Class I Div 1 means · every gas monitor by gas, sampling and battery.
Honeywell BW MicroClip X3 documents
- Honeywell BW MicroClip Series Data Sheet (PDF)
- BW MicroClip Series Quick Reference Guide Rev B EN (PDF)
- Honeywell BW MicroClip Series - User Manual (PDF)
- Honeywell BW MicroClip Series - User Manual (PDF)
- Honeywell BW MicroClip Series Certificate of Compliance (PDF)
- Honeywell BW MicroClip Series Certificate of Approval (PDF)
- BW MicroClip Series IECEx Certificate of Conformity (PDF)
- BW MicroClip Series ATEX Certificate (PDF)
- BW MicroClip Series EU Declaration of Conformity (PDF)
- BW MicroClip Series ABS Certificate of Design Assessment Calgary (PDF)
- BW MicroClip Series AS/NSZ Declaration of Conformity (PDF)
- BW MicroClip Series Marine Certificate of Design Assessment Juarez (PDF)
Source: Honeywell BW product page https://automation.honeywell.com/us/en/products/gas-and-flame-detection/portables/multi-gas/honeywell-bw-microclip-series-multi-gas-detector (documents list).