The Draeger Dimethyl Sulfate 0.005/c Detector Tubes, Box of 9 falls under detector tubes & pumps. Gases detected Dimethyl sulfate; measuring range 0.005-0.05 ppm; capacity 9 tubes per box. Draeger lists Standard measuring range: 0.005-0.05 ppm; Box of 9 single-use tubes, one measurement per tube; See the instruction sheet in each box for pump strokes and cross-sensitivities. Sold by the box.
Draeger 6718701 specifications
| Item | Draeger data |
|---|---|
| Part number | 6718701 |
| Gases Detected | Dimethyl sulfate |
| Measuring Range | 0.005-0.05 ppm |
| Style | Short-term detector tube |
| Capacity | 9 tubes per box |
Source: Draeger published product data.
Draeger 6718701 questions
What is the Draeger 6718701? The Draeger Dimethyl Sulfate 0.005/c Detector Tubes, Box of 9 falls under detector tubes & pumps. Gases detected Dimethyl sulfate; measuring range 0.005-0.05 ppm; capacity 9 tubes per box.
How is the 6718701 sold? By the box.
What range does the 6718701 measure? 0.005-0.05 ppm, per Draeger.
What gases does the 6718701 detect? Dimethyl sulfate.
Draeger Dimethyl Sulfate detector tubes measure dimethyl sulfate in air with a simple color-change reading, no power or calibration needed. They are a common spot-check tool for chemical synthesis where dimethyl sulfate is used as a methylating agent. Each tube works with the Draeger accuro or other Draeger tube pumps.
- Standard measuring range: 0.005-0.05 ppm
- Works with the Draeger accuro and other Draeger tube pumps
- Box of 9 single-use tubes, one measurement per tube
- Color change read directly against the printed scale on the tube
- See the instruction sheet in each box for pump strokes and cross-sensitivities
Draeger part number: 6718701.