Gastec 14L falls under detector tubes & pumps and is made of glass. Gases detected Hydrogen Chloride. Gastec lists Measures hydrogen chloride, 0.2 to 76 ppm; TLV: 2 ppm; Detecting limit 0.05 ppm; Glass tube; break both ends before sampling. Sold by the box.
Gastec 14L specifications
| Item | Gastec data |
|---|---|
| Part number | 14L |
| Gases Detected | Hydrogen Chloride |
| Material | Glass |
| Style | Detector Tube |
Source: Gastec published product data.
Gastec 14L questions
What is the Gastec 14L? Gastec 14L falls under detector tubes & pumps and is made of glass. Gases detected Hydrogen Chloride.
How is the 14L sold? By the box.
What gases does the 14L detect? Hydrogen Chloride.
What is the 14L made of? Glass, per Gastec.
A Gastec colorimetric detector tube for spot-checking hydrogen chloride in workplace air. Draw a sample with a Gastec hand pump and read the concentration from the length of the color stain, a quick and low-cost check without an electronic monitor.
- Measures hydrogen chloride, 0.2 to 76 ppm
- Color change: yellow to pink
- TLV: 2 ppm
- Detecting limit 0.05 ppm
- Glass tube; break both ends before sampling
- Use with a Gastec hand pump; avoid touching broken glass or reagent with bare hands
Manufacturer item number: 14L.
Sold by the box
The price shown is for the full box; quantity 1 = 1 box.