Description
RKI Instruments 72-FE-A-A10 is the GX-Force 3 gas detector with a built-in pump, a sample-draw gas monitor configured for combustible gas (LEL, methane as standard), oxygen (O2) and hydrogen sulfide (H2S). This configuration ships with 10 ft hose and probe, belt clip, USB Type-C cable and rubber nozzle, with an AC adapter, as the RKI product data file lists it. Internal sample pump with a 100 ft sampling range; RKI rates the Li-ion battery at approx. 30 hours (25 °C, fully charged, no alarm, no backlight) and charges it by USB Type-C. Two operating modes: Normal, and Leak Check, which reads combustibles in the ppm range. IP67 equivalent dust and water resistance; approvals as RKI lists them: ATEX, IECEx, QPS C/US Class I Div 1 Groups A, B, C, D. Warranty 3 years. Sold individually. Every GX-Force configuration we stock (73) is on one page with prices. Ships in 1–2 business days; most orders arrive in 3–7 business days.
RKI Instruments 72-FE-A-A10 specifications
| Item | RKI Instruments data |
|---|---|
| Part number | 72-FE-A-A10 |
| Model | GX-Force |
| RKI configuration | GX-Force,LEL/O2/H2S,AC adapter,USB cable,belt clip,rubber nozzle,10ft hose/probe |
| Gases Detected | LEL; O2; H2S |
| Number of Gases | 3 |
| Sensors | LEL: Catalytic combustion (CH4 or HC); O2: Electrochemical; H2S: Electrochemical |
| Sensor Ranges | LEL 0-100% LEL; O2 0-40.0% vol; H2S 0-200.0 ppm |
| Sample Method | Pump (sample draw) (Internal sample pump, nominal 0.5 L/min, 100 ft sample range, hydrophobic filter) |
| Hose Length | 10 ft |
| Battery | Li-Ion |
| Charger | AC adapter |
| Battery Life | Approx. 30 hours (25 °C, fully charged, no alarm, no backlight) |
| Includes | 10 ft hose and probe; Belt clip; USB Type-C cable; Rubber nozzle |
| Alarms | Gas alarm: lamp flashing, continuous modulating buzzer, gas concentration display flashing, vibration; self-resetting or latching. Fault alarm: system, clock or sensor abnormality, battery voltage drop, calibration failure, pump abnormality, low flow rate |
| Alarm display | Lamp flashing, continuous modulating buzzer (approx. 90 dB at 30 cm), gas concentration display flashing, vibration |
| Display | LCD digital (7-segment + 14-segment + icons) with backlight |
| Datalogging | Maximum 3,600 items, 5-minute interval (adjustable); USB 2.0 Type-C connection |
| Response time | CH4 within 30 seconds, HC within 40 seconds (LEL); O2 within 20 seconds; CO and H2S within 30 seconds (T90) |
| Operating temperature and humidity | -20 to +50 °C (-4 to +122 °F), no sudden changes; 0 to 95% RH non-condensing |
| Case | IP67 equivalent |
| Dimensions | approx. 2.52 in W x 6.81 in H x 1.85 in D (excluding protrusions) |
| Weight | approx. 9.87 oz |
| RKI product data file dimensions | 2.52 x 6.81 x 1.85 in (W x H x D), 9.87 oz |
| Shipping package | 10 x 10 x 4 in, 4 lbs |
| Standard accessories (model) | USB Type-C cable, belt clip, rubber nozzle (per configuration: AC adapter, 12 VDC car adapter, hose and probe) |
| Optional accessories | Carrying case, calibration kit, SDM-Force calibration station |
| Approvals | Intrinsically safe construction: IECEx Ex da ia IIC T4 Ga / Ex ia IIC T4 Ga; ATEX II1G Ex da ia IIC T4 Ga / II1G Ex ia IIC T4 Ga; c QPS us Class I, Div 1, Groups A, B, C, D, Ex da ia IIC T4 Ga (with NCR-6309 LEL sensor) / Ex ia IIC T4 Ga (without); Class I, Zone 0 AEx da ia IIC T4 Ga / AEx ia IIC T4 Ga |
| RKI product data file certification flags | CSA Yes; UL Yes |
| Warranty | Three years material and workmanship |
| Country of origin | Japan |
| Unit of sale | Each (RKI: unit of measurement Each, minimum purchase 1) |
Source: RKI Instruments product page https://www.rkiinstruments.com/product/gx-force-portable-4-gas-monitor/, fetched Nov 8 2026; RKI Instruments GX-Force datasheet (PDF); RKI Instruments product data file, Sept 2026 (configuration, dimensions, weight, warranty, country of origin, certification flags). Approvals and figures are as RKI publishes them.
Detectable gases on the 72-FE-A-A10
| Gas | Sensor | Measuring range (increment) | Accuracy | Preset alarms |
|---|---|---|---|---|
| LEL | Catalytic combustion (CH4 or HC) | 0 - 100% LEL (1% LEL) | Not stated on the RKI page | 1st 10% LEL; 2nd 25% LEL; 3rd 50% LEL; OVER 100% LEL |
| O2 | Electrochemical | 0.0 - 40.0 vol% (0.1 vol%) | Not stated on the RKI page | L 19.5 vol%; LL 18.0 vol%; H 23.5 vol%; OVER 40.0 vol% |
| H2S | Electrochemical | 0.0 - 200.0 ppm (0.1 ppm) | Not stated on the RKI page | 1st 5.0 ppm; 2nd 30.0 ppm; 3rd 100.0 ppm; TWA 1.0 ppm; STEL 5.0 ppm; OVER 200.0 ppm |
Source: RKI Instruments product page https://www.rkiinstruments.com/product/gx-force-portable-4-gas-monitor/, fetched Nov 8 2026 (detectable gases table). Preset alarm levels are RKI's factory settings and are user adjustable; they are not exposure limits.
Exposure limits for the gases the 72-FE-A-A10 detects
| Gas | CAS | OSHA PEL | NIOSH REL | NIOSH IDLH |
|---|---|---|---|---|
| Hydrogen sulfide (H2S) | 7783-06-4 | C 20 ppm 50 ppm [10-minute maximum peak] | C 10 ppm (15 mg/m³) [10-minute] | 100 ppm |
29 CFR 1910.146(b) defines a hazardous atmosphere to include a flammable gas, vapor or mist in excess of 10 percent of its lower flammable limit (LFL), an atmospheric oxygen concentration below 19.5 percent or above 23.5 percent, and any atmospheric concentration of a substance that could result in employee exposure in excess of its dose or permissible exposure limit.
Source: NIOSH Pocket Guide to Chemical Hazards (OSHA PEL, NIOSH REL and IDLH, CAS number, as published); 29 CFR 1910.146(b) for the oxygen and flammable-gas definitions. Limits are the published figures, not a recommendation for any task.
Features
- 2 Operating modes - Normal and Leak Check
- Internal sample pump with 100 ft sample range
- 30 hours of operation (Lithium-ion battery)
- USB Type-C charging & data connection
- Easy to grip lightweight design - 2.5 in W x 6.81 in H x 1.85 in D, 9.87 ounces
- Water and dust resistant design, IP67
- Field replaceable sensors & filters
- Impact resistant body
- Intrinsically safe
- Large LCD Auto-backlit display
- 3 Year warranty
Source: RKI Instruments GX-Force feature list, RKI Instruments product page https://www.rkiinstruments.com/product/gx-force-portable-4-gas-monitor/, fetched Nov 8 2026.
RKI Instruments GX-Force documents
- GX-Force Datasheet (PDF) - datasheet
- GX-Force Manual (PDF) - operator's manual
- GX-Force Datalogging Manual (PDF) - datalogging manual
Source: RKI Instruments GX-Force downloads, RKI Instruments product page https://www.rkiinstruments.com/product/gx-force-portable-4-gas-monitor/, fetched Nov 8 2026.
RKI Instruments GX-Force LEL/O2/H2S configurations
| Part number | Gases | Battery | Charger | Kit contents | Price |
|---|---|---|---|---|---|
| 72-FE-B-A10 | LEL/O2/H2S | Li-Ion | 12 VDC car adapter | 10 ft hose and probe | $773.50 |
| 72-FE-A-A10 | LEL/O2/H2S | Li-Ion | AC adapter | 10 ft hose and probe | $773.50 |
| 72-FE-A-A5 | LEL/O2/H2S | Li-Ion | AC adapter | 5 ft hose and probe | $769.25 |
| 72-FE-C-A10 | LEL/O2/H2S | Li-Ion | AC adapter; 12 VDC car adapter | 5 ft hose and probe | $820.25 |
| 72-FE-D-A10 | LEL/O2/H2S | Li-Ion | None (USB Type-C cable only) | 5 ft hose and probe | $726.75 |
Every GX-Force configuration we stock (73) is on the GX-Force page; the RKI model page lists the sensor options LEL, O2, CO, CO (H2-compensated), H2S.
Source: RKI Instruments product data file, Sept 2026 (configuration per part number); prices from the store.
RKI Instruments 72-FE-A-A10 questions
What does the 72-FE-A-A10 3 gas detector detect? Combustible gas (LEL, methane as standard), oxygen (O2) and hydrogen sulfide (H2S). It is the GX-Force configured with 3 sensors; RKI lists the range and preset alarms for each in the table above.
At what levels does the 72-FE-A-A10 alarm go off? RKI's factory alarm settings on the 72-FE-A-A10: LEL 1st 10% LEL; 2nd 25% LEL; 3rd 50% LEL; OVER 100% LEL; O2 L 19.5 vol%; LL 18.0 vol%; H 23.5 vol%; OVER 40.0 vol%; H2S 1st 5.0 ppm; 2nd 30.0 ppm; 3rd 100.0 ppm; TWA 1.0 ppm; STEL 5.0 ppm; OVER 200.0 ppm. They are user adjustable, and they are RKI's presets, not exposure limits; the detectable gases table above has the full row for each gas.
Is the 72-FE-A-A10 intrinsically safe? Yes. RKI lists an intrinsically safe construction for the GX-Force: Intrinsically safe construction: IECEx Ex da ia IIC T4 Ga / Ex ia IIC T4 Ga; ATEX II1G Ex da ia IIC T4 Ga / II1G Ex ia IIC T4 Ga; c QPS us Class I, Div 1, Groups A, B, C, D, Ex da ia IIC T4 Ga (with NCR-6309 LEL sensor) / Ex ia IIC T4 Ga (without); Class I, Zone 0 AEx da ia IIC T4 Ga / AEx ia IIC T4 Ga.
How far can the 72-FE-A-A10 draw a sample? RKI lists an internal sample pump with a 100 ft sample range, nominal flow 0.5 L/min, with a hydrophobic filter. This configuration ships with a 10 ft hose and probe.
How do you calibrate the 72-FE-A-A10? With an RKI calibration kit or in the SDM-Force calibration station, both of which RKI lists as optional accessories for the GX-Force. The steps are in our guide how to calibrate an RKI GX-Force or GX-3R Pro.
How long does the 72-FE-A-A10 battery last? RKI rates it at approx. 30 hours (25 °C, fully charged, no alarm, no backlight); it charges by USB Type-C.
Guides: what LEL means · oxygen deficiency and enrichment · H2S exposure limits · bump test vs calibration · how to read a gas monitor alarm · confined space gas testing order · what Class I Div 1 means · every gas monitor by gas, sampling and battery · how to calibrate a GX-Force or GX-3R Pro · what 20% LEL means and LEL alarm set points.
Manufacturer item number: 72-FE-A-A10. Datasheet: RKI Instruments GX-Force datasheet (PDF).
The RKI 72-FE-A-A10 is a GX-Force 3-gas sample-draw gas monitor configured to detect combustible gas (LEL), oxygen (O2) and hydrogen sulfide (H2S). This configuration ships with a 100-240 VAC charger, 10 ft sample hose and probe, a belt clip, a USB cable and a rubber nozzle. The GX-Force is a compact sample-draw monitor with an internal pump rated for a 100 ft sample range, Normal and Leak Check operating modes, 30 hours of run time on the lithium-ion battery, USB Type-C charging and data connection and an IP67 water- and dust-resistant design.
- Internal sample pump with 100′ sample range
Item number: 72-FE-A-A10. Sold individually. Warranty: 3 years. Country of origin: Japan.