RKI Instruments 72-FE-A-A10 is the GX-Force 3 gas detector with a built-in pump, a sample-draw gas monitor configured for combustible gas (LEL, methane as standard), oxygen (O2) and hydrogen sulfide (H2S). This configuration ships with 10 ft hose and probe, belt clip, USB Type-C cable and rubber nozzle, with an AC adapter, as the RKI product data file lists it. Internal sample pump with a 100 ft sampling range; RKI rates the Li-ion battery at approx. 30 hours (25 °C, fully charged, no alarm, no backlight) and charges it by USB Type-C. Two operating modes: Normal, and Leak Check, which reads combustibles in the ppm range. IP67 equivalent dust and water resistance; approvals as RKI lists them: ATEX, IECEx, QPS C/US Class I Div 1 Groups A, B, C, D. Warranty 3 years. Sold individually. Every GX-Force configuration we stock (73) is on one page with prices. Ships in 1–2 business days; most orders arrive in 3–7 business days.

RKI Instruments 72-FE-A-A10 specifications

ItemRKI Instruments data
Part number72-FE-A-A10
ModelGX-Force
RKI configurationGX-Force,LEL/O2/H2S,AC adapter,USB cable,belt clip,rubber nozzle,10ft hose/probe
Gases DetectedLEL; O2; H2S
Number of Gases3
SensorsLEL: Catalytic combustion (CH4 or HC); O2: Electrochemical; H2S: Electrochemical
Sensor RangesLEL 0-100% LEL; O2 0-40.0% vol; H2S 0-200.0 ppm
Sample MethodPump (sample draw) (Internal sample pump, nominal 0.5 L/min, 100 ft sample range, hydrophobic filter)
Hose Length10 ft
BatteryLi-Ion
ChargerAC adapter
Battery LifeApprox. 30 hours (25 °C, fully charged, no alarm, no backlight)
Includes10 ft hose and probe; Belt clip; USB Type-C cable; Rubber nozzle
AlarmsGas alarm: lamp flashing, continuous modulating buzzer, gas concentration display flashing, vibration; self-resetting or latching. Fault alarm: system, clock or sensor abnormality, battery voltage drop, calibration failure, pump abnormality, low flow rate
Alarm displayLamp flashing, continuous modulating buzzer (approx. 90 dB at 30 cm), gas concentration display flashing, vibration
DisplayLCD digital (7-segment + 14-segment + icons) with backlight
DataloggingMaximum 3,600 items, 5-minute interval (adjustable); USB 2.0 Type-C connection
Response timeCH4 within 30 seconds, HC within 40 seconds (LEL); O2 within 20 seconds; CO and H2S within 30 seconds (T90)
Operating temperature and humidity-20 to +50 °C (-4 to +122 °F), no sudden changes; 0 to 95% RH non-condensing
CaseIP67 equivalent
Dimensionsapprox. 2.52 in W x 6.81 in H x 1.85 in D (excluding protrusions)
Weightapprox. 9.87 oz
RKI product data file dimensions2.52 x 6.81 x 1.85 in (W x H x D), 9.87 oz
Shipping package10 x 10 x 4 in, 4 lbs
Standard accessories (model)USB Type-C cable, belt clip, rubber nozzle (per configuration: AC adapter, 12 VDC car adapter, hose and probe)
Optional accessoriesCarrying case, calibration kit, SDM-Force calibration station
ApprovalsIntrinsically safe construction: IECEx Ex da ia IIC T4 Ga / Ex ia IIC T4 Ga; ATEX II1G Ex da ia IIC T4 Ga / II1G Ex ia IIC T4 Ga; c QPS us Class I, Div 1, Groups A, B, C, D, Ex da ia IIC T4 Ga (with NCR-6309 LEL sensor) / Ex ia IIC T4 Ga (without); Class I, Zone 0 AEx da ia IIC T4 Ga / AEx ia IIC T4 Ga
RKI product data file certification flagsCSA Yes; UL Yes
WarrantyThree years material and workmanship
Country of originJapan
Unit of saleEach (RKI: unit of measurement Each, minimum purchase 1)

Source: RKI Instruments product page https://www.rkiinstruments.com/product/gx-force-portable-4-gas-monitor/, fetched Nov 8 2026; RKI Instruments GX-Force datasheet (PDF); RKI Instruments product data file, Sept 2026 (configuration, dimensions, weight, warranty, country of origin, certification flags). Approvals and figures are as RKI publishes them.

Detectable gases on the 72-FE-A-A10

GasSensorMeasuring range (increment)AccuracyPreset alarms
LELCatalytic combustion (CH4 or HC)0 - 100% LEL (1% LEL)Not stated on the RKI page1st 10% LEL; 2nd 25% LEL; 3rd 50% LEL; OVER 100% LEL
O2Electrochemical0.0 - 40.0 vol% (0.1 vol%)Not stated on the RKI pageL 19.5 vol%; LL 18.0 vol%; H 23.5 vol%; OVER 40.0 vol%
H2SElectrochemical0.0 - 200.0 ppm (0.1 ppm)Not stated on the RKI page1st 5.0 ppm; 2nd 30.0 ppm; 3rd 100.0 ppm; TWA 1.0 ppm; STEL 5.0 ppm; OVER 200.0 ppm

Source: RKI Instruments product page https://www.rkiinstruments.com/product/gx-force-portable-4-gas-monitor/, fetched Nov 8 2026 (detectable gases table). Preset alarm levels are RKI's factory settings and are user adjustable; they are not exposure limits.

Exposure limits for the gases the 72-FE-A-A10 detects

GasCASOSHA PELNIOSH RELNIOSH IDLH
Hydrogen sulfide (H2S)7783-06-4C 20 ppm 50 ppm [10-minute maximum peak]C 10 ppm (15 mg/m³) [10-minute]100 ppm

29 CFR 1910.146(b) defines a hazardous atmosphere to include a flammable gas, vapor or mist in excess of 10 percent of its lower flammable limit (LFL), an atmospheric oxygen concentration below 19.5 percent or above 23.5 percent, and any atmospheric concentration of a substance that could result in employee exposure in excess of its dose or permissible exposure limit.

Source: NIOSH Pocket Guide to Chemical Hazards (OSHA PEL, NIOSH REL and IDLH, CAS number, as published); 29 CFR 1910.146(b) for the oxygen and flammable-gas definitions. Limits are the published figures, not a recommendation for any task.

Features

  • 2 Operating modes - Normal and Leak Check
  • Internal sample pump with 100 ft sample range
  • 30 hours of operation (Lithium-ion battery)
  • USB Type-C charging & data connection
  • Easy to grip lightweight design - 2.5 in W x 6.81 in H x 1.85 in D, 9.87 ounces
  • Water and dust resistant design, IP67
  • Field replaceable sensors & filters
  • Impact resistant body
  • Intrinsically safe
  • Large LCD Auto-backlit display
  • 3 Year warranty

Source: RKI Instruments GX-Force feature list, RKI Instruments product page https://www.rkiinstruments.com/product/gx-force-portable-4-gas-monitor/, fetched Nov 8 2026.

RKI Instruments GX-Force documents

Source: RKI Instruments GX-Force downloads, RKI Instruments product page https://www.rkiinstruments.com/product/gx-force-portable-4-gas-monitor/, fetched Nov 8 2026.

RKI Instruments GX-Force LEL/O2/H2S configurations

Part numberGasesBatteryChargerKit contentsPrice
72-FE-B-A10LEL/O2/H2SLi-Ion12 VDC car adapter10 ft hose and probe$773.50
72-FE-A-A10LEL/O2/H2SLi-IonAC adapter10 ft hose and probe$773.50
72-FE-A-A5LEL/O2/H2SLi-IonAC adapter5 ft hose and probe$769.25
72-FE-C-A10LEL/O2/H2SLi-IonAC adapter; 12 VDC car adapter5 ft hose and probe$820.25
72-FE-D-A10LEL/O2/H2SLi-IonNone (USB Type-C cable only)5 ft hose and probe$726.75

Every GX-Force configuration we stock (73) is on the GX-Force page; the RKI model page lists the sensor options LEL, O2, CO, CO (H2-compensated), H2S.

Source: RKI Instruments product data file, Sept 2026 (configuration per part number); prices from the store.

RKI Instruments 72-FE-A-A10 questions

What does the 72-FE-A-A10 3 gas detector detect? Combustible gas (LEL, methane as standard), oxygen (O2) and hydrogen sulfide (H2S). It is the GX-Force configured with 3 sensors; RKI lists the range and preset alarms for each in the table above.

At what levels does the 72-FE-A-A10 alarm go off? RKI's factory alarm settings on the 72-FE-A-A10: LEL 1st 10% LEL; 2nd 25% LEL; 3rd 50% LEL; OVER 100% LEL; O2 L 19.5 vol%; LL 18.0 vol%; H 23.5 vol%; OVER 40.0 vol%; H2S 1st 5.0 ppm; 2nd 30.0 ppm; 3rd 100.0 ppm; TWA 1.0 ppm; STEL 5.0 ppm; OVER 200.0 ppm. They are user adjustable, and they are RKI's presets, not exposure limits; the detectable gases table above has the full row for each gas.

Is the 72-FE-A-A10 intrinsically safe? Yes. RKI lists an intrinsically safe construction for the GX-Force: Intrinsically safe construction: IECEx Ex da ia IIC T4 Ga / Ex ia IIC T4 Ga; ATEX II1G Ex da ia IIC T4 Ga / II1G Ex ia IIC T4 Ga; c QPS us Class I, Div 1, Groups A, B, C, D, Ex da ia IIC T4 Ga (with NCR-6309 LEL sensor) / Ex ia IIC T4 Ga (without); Class I, Zone 0 AEx da ia IIC T4 Ga / AEx ia IIC T4 Ga.

How far can the 72-FE-A-A10 draw a sample? RKI lists an internal sample pump with a 100 ft sample range, nominal flow 0.5 L/min, with a hydrophobic filter. This configuration ships with a 10 ft hose and probe.

How do you calibrate the 72-FE-A-A10? With an RKI calibration kit or in the SDM-Force calibration station, both of which RKI lists as optional accessories for the GX-Force. The steps are in our guide how to calibrate an RKI GX-Force or GX-3R Pro.

How long does the 72-FE-A-A10 battery last? RKI rates it at approx. 30 hours (25 °C, fully charged, no alarm, no backlight); it charges by USB Type-C.

Guides: what LEL means · oxygen deficiency and enrichment · H2S exposure limits · bump test vs calibration · how to read a gas monitor alarm · confined space gas testing order · what Class I Div 1 means · every gas monitor by gas, sampling and battery · how to calibrate a GX-Force or GX-3R Pro · what 20% LEL means and LEL alarm set points.

Manufacturer item number: 72-FE-A-A10. Datasheet: RKI Instruments GX-Force datasheet (PDF).

The RKI 72-FE-A-A10 is a GX-Force 3-gas sample-draw gas monitor configured to detect combustible gas (LEL), oxygen (O2) and hydrogen sulfide (H2S). This configuration ships with a 100-240 VAC charger, 10 ft sample hose and probe, a belt clip, a USB cable and a rubber nozzle. The GX-Force is a compact sample-draw monitor with an internal pump rated for a 100 ft sample range, Normal and Leak Check operating modes, 30 hours of run time on the lithium-ion battery, USB Type-C charging and data connection and an IP67 water- and dust-resistant design.

  • Internal sample pump with 100′ sample range

Item number: 72-FE-A-A10. Sold individually. Warranty: 3 years. Country of origin: Japan.

Usually ships in 1–2 business days; delivery in 3–7 business days.

Adding to cart… The item has been added
Specifications
Product TypeGas Monitor
ModelGX-Force
Gases DetectedLEL; O2; H2S
Number of Gases3
Sample MethodPump (sample draw)
BatteryLi-Ion
ChargerAC adapter
Includes10 ft hose and probe; Belt clip; USB Type-C cable; Rubber nozzle
Hose Length10 ft
Warranty3 years
StandardsATEX, IECEx, QPS C/US Class I Div 1 Groups A, B, C, D
Country of OriginJapan
Dimensions (each)2.52 x 6.81 x 1.85 in (W x H x L)
Shipping Package10 x 10 x 4 in (W x H x D), 4 lbs
Sensor RangesLEL 0-100% LEL; O2 0-40.0% vol; H2S 0-200.0 ppm
Battery LifeApprox. 30 hours (25 °C, fully charged, no alarm, no backlight)
Ingress ProtectionIP67 equivalent
Weight9.87 oz
Shipping & returns

In-stock orders: 1–2 business days to process, then 2–5 business days by ground (3–7 in all); regular rates apply and Contractor Direct orders ship free. Most items can be returned within 30 days in new, resalable condition; respirators, filters and other hygiene items are final sale. Shipping policy · Returns policy

RKI Instruments 72-FE-A-A10 GX-Force 3-Gas Sample-Draw Monitor, LEL/O2/H2S$773.50

More RKI Instruments and other brands in this category

Reviews

No reviews yet. Used this on the job? Tell other crews how it held up.

Write a review ›
How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.