Description
RKI Instruments 72-PJX-D is the GX-3R Pro 2 gas detector, a personal gas monitor configured for combustible gas (LEL, methane as standard) and hydrogen sulfide (H2S). This configuration ships with the Li-ion battery pack and a 12 VDC charger, as the RKI product data file lists it. RKI rates the run time at 25 hours on the Li-ion pack (23 hours with Bluetooth on) for a 4-gas plus electrochemical configuration; the Li-ion pack charges in 3 hours. Diffusion sampling; the RP-3R Pro clip-on pump is optional. Bluetooth to the free RK Link app, man-down and panic alarms, a non-compliance indicator and field-replaceable sensors and filters are standard on the GX-3R Pro. IP-66/68 (2 m, 1 h) dust and water resistance; approvals as RKI lists them: ATEX, CSA, IECEx, MED. Warranty 3 years (1 year for the ammonia sensor). Sold individually. Every GX-3R Pro configuration we stock (334) is on one page with prices. Ships in 1–2 business days; most orders arrive in 3–7 business days.
RKI Instruments 72-PJX-D specifications
| Item | RKI Instruments data |
|---|---|
| Part number | 72-PJX-D |
| Model | GX-3R Pro |
| RKI configuration | GX-3R Pro,LEL/H2S,with Li-Ion battery & 12 VDC charger |
| Gases Detected | LEL; H2S |
| Number of Gases | 2 |
| Sensors | LEL: Catalytic (methane as standard); H2S: Electrochemical (dual sensor with CO, or H2S only) |
| Sensor Ranges | LEL 0-100% LEL; H2S 0-200.0 ppm |
| Sample Method | Diffusion |
| Battery | Li-Ion |
| Charger | 12 VDC |
| Battery Life | Li-ion 25 hours (23 hours with Bluetooth on), 3 hour full charge |
| Alarms | Gas alarm: 2 increasing alarms, STEL, TWA, over-scale, O2 decreasing/increasing; man down alarm; panic alarm. Trouble alarm: sensor disconnection, low battery, circuit error, calibration range error, cal or bump due |
| Alarm display | Flashing LEDs, continuous buzzer (100 dB at 30 cm), flashing gas value, vibration |
| Display | Full dot LCD with auto backlight and auto rotation |
| Bluetooth | Bluetooth (BLE) to the RK Link iOS and Android app |
| Datalogging | Logs user ID, station ID, calibration and bump test history, alarm events and alarm trends |
| Response time | Within 30 seconds (T90) |
| Operating temperature and humidity | -20 to +50 °C (-4 to +122 °F), 10 to 90% RH non-condensing (continuous); -40 to +60 °C (-40 to +140 °F), 0 to 95% RH (temporary) |
| Case | IP-66/68 (2 m, 1 h); drop height 23 ft |
| Dimensions | 2.9 in W x 2.6 in H x 1.06 in D (approx. 73 x 65 x 26 mm) |
| Weight | 4.58 oz with rubber boot |
| RKI product data file dimensions | 2.9 x 2.6 x 1.06 in (W x H x D), 4.58 oz |
| Shipping package | 9 x 6 x 5 in, 2 lbs |
| Standard accessories (model) | Alligator clip, protective rubber boot, charger, calibration adapter |
| Optional accessories | Padded carrying case; RP-3R attachable sampling pump with 4 in rubber nipple, 10 ft hose and probe (up to 100 ft hose available); USB to IrDA downloading cable; SDM-3R calibration station; hand aspirator |
| Approvals | ATEX, CSA, IECEx, MED |
| RKI product data file certification flags | CSA Yes; UL No |
| Warranty | Three years material and workmanship including sensors (1 year for ammonia sensor) |
| Country of origin | Japan |
| Unit of sale | Each (RKI: unit of measurement Each, minimum purchase 1) |
Source: RKI Instruments product page https://www.rkiinstruments.com/product/gx-3r-pro-gas-detector/, fetched Nov 8 2026; RKI Instruments GX-3R Pro datasheet (PDF); RKI Instruments product data file, Sept 2026 (configuration, dimensions, weight, warranty, country of origin, certification flags). Approvals and figures are as RKI publishes them.
Detectable gases on the 72-PJX-D
| Gas | Sensor | Measuring range (increment) | Accuracy | Preset alarms |
|---|---|---|---|---|
| LEL | Catalytic (methane as standard) | 0 ~ 100% LEL (1% LEL) | ± 5% of reading or ± 2% LEL | 1st 10% LEL; 2nd 25% LEL; 3rd 50% LEL; Over 100% LEL |
| H2S | Electrochemical (dual sensor with CO, or H2S only) | 0 ~ 200.0 ppm (0.1 ppm) | ± 5% of reading or ± 2 ppm H2S | A1 5 ppm; A2 30 ppm; A3 100 ppm; TWA 1.0 ppm; STEL 5.0 ppm |
Source: RKI Instruments product page https://www.rkiinstruments.com/product/gx-3r-pro-gas-detector/, fetched Nov 8 2026 (detectable gases table). Preset alarm levels are RKI's factory settings and are user adjustable; they are not exposure limits.
Exposure limits for the gases the 72-PJX-D detects
| Gas | CAS | OSHA PEL | NIOSH REL | NIOSH IDLH |
|---|---|---|---|---|
| Hydrogen sulfide (H2S) | 7783-06-4 | C 20 ppm 50 ppm [10-minute maximum peak] | C 10 ppm (15 mg/m³) [10-minute] | 100 ppm |
29 CFR 1910.146(b) defines a hazardous atmosphere to include a flammable gas, vapor or mist in excess of 10 percent of its lower flammable limit (LFL), an atmospheric oxygen concentration below 19.5 percent or above 23.5 percent, and any atmospheric concentration of a substance that could result in employee exposure in excess of its dose or permissible exposure limit.
Source: NIOSH Pocket Guide to Chemical Hazards (OSHA PEL, NIOSH REL and IDLH, CAS number, as published); 29 CFR 1910.146(b) for the oxygen and flammable-gas definitions. Limits are the published figures, not a recommendation for any task.
Features
- Smallest & lightest detector
- Detect up to 5 gases simultaneously - Confined Space: LEL, O2, H2S, CO - Toxics/IR Sensors: HCN, NH3, NO2, PH3, SO2, and CO2 - H2 Compensated CO sensor available
- Simple 2-button operation
- Bluetooth communication with iOS & Android App
- 3 user adjustable alarm levels
- Panic Alarm & Man Down Alarm
- Large full dot, auto-backlit display with auto-rotation
- Field replaceable sensors & filters
- Water and dust resistant design, IP66/68
- 3 Year Warranty*
Source: RKI Instruments GX-3R Pro feature list, RKI Instruments product page https://www.rkiinstruments.com/product/gx-3r-pro-gas-detector/, fetched Nov 8 2026.
- Smallest & lightest 5 gas monitor
- Non-Compliance Indicator
- Man Down Alarm
Source: RKI Instruments product data file, Sept 2026, features for 72-PJX-D.
RKI Instruments GX-3R Pro documents
- GX-3R Pro Datasheet (PDF) - datasheet
- GX-3R Pro Manual CSA/ATEX Approval Version (PDF) - operator's manual
- GX-3R Pro Quick Reference Card (PDF) - quick reference card
- GX-3R Pro Datalogging Manual (PDF) - datalogging manual
- RK Link App User Manual (PDF) - RK Link app manual
- TIIS Approval Certificate for EX-Equipment (PDF) - TIIS approval certificate
- Lithium Ion Battery SDS (PDF) - lithium-ion battery SDS
- RKI Instruments video: GX-3R and GX-3R Pro Overview - video
Source: RKI Instruments GX-3R Pro downloads, RKI Instruments product page https://www.rkiinstruments.com/product/gx-3r-pro-gas-detector/, fetched Nov 8 2026; video link from the RKI Instruments product data file, Sept 2026.
RKI Instruments GX-3R Pro LEL/H2S configurations
| Part number | Gases | Battery | Charger | Kit contents | Price |
|---|---|---|---|---|---|
| 72-PJX-A | LEL/H2S | Alkaline | None | — | $667.25 |
| 72-PJX-B | LEL/H2S | Alkaline & Li-Ion | 100-240 VAC | — | $939.25 |
| 72-PJX-C | LEL/H2S | Li-Ion | 100-240 VAC | — | $832.15 |
| 72-PJX-D | LEL/H2S | Li-Ion | 12 VDC | — | $811.75 |
Every GX-3R Pro configuration we stock (334) is on the GX-3R Pro page; the RKI model page lists the sensor options CO, CO (H2-compensated), H2S, LEL, O2, CO2 %, CO2 ppm, SO2, HCN, NH3, NO2, PH3.
Source: RKI Instruments product data file, Sept 2026 (configuration per part number); prices from the store.
RKI Instruments 72-PJX-D questions
What does the 72-PJX-D 2 gas detector detect? Combustible gas (LEL, methane as standard) and hydrogen sulfide (H2S). It is the GX-3R Pro configured with 2 sensors; RKI lists the range and preset alarms for each in the table above.
At what levels does the 72-PJX-D alarm go off? RKI's factory alarm settings on the 72-PJX-D: LEL 1st 10% LEL; 2nd 25% LEL; 3rd 50% LEL; Over 100% LEL; H2S A1 5 ppm; A2 30 ppm; A3 100 ppm; TWA 1.0 ppm; STEL 5.0 ppm. They are user adjustable, and they are RKI's presets, not exposure limits; the detectable gases table above has the full row for each gas.
Is the 72-PJX-D ATEX approved? RKI lists the GX-3R Pro with ATEX, CSA, IECEx, MED approvals (RKI product data file: CSA yes). RKI does not spell the Ex marking out on the product page we cite, so take the marking from the GX-3R Pro datasheet linked in the documents list above.
Does the 72-PJX-D have a pump? Not built in: the GX-3R Pro is a diffusion monitor. RKI lists the RP-3R Pro clip-on motorized pump (10 ft hose and probe, up to 100 ft hose) and a hand aspirator as optional accessories.
How do you calibrate the 72-PJX-D? With RKI calibration gas through the calibration adapter that ships with it, or in the SDM-3R calibration station, which RKI lists as an optional accessory; the GX-3R Pro raises a trouble alarm when a calibration or bump test is due and logs calibration and bump test history, as RKI lists it. The steps are in our guide how to calibrate an RKI GX-Force or GX-3R Pro.
How long does the 72-PJX-D battery last? RKI rates 25 hours on the Li-ion pack, 23 hours with Bluetooth on, and a 3-hour full charge for a 4-gas plus electrochemical configuration.
Guides: what LEL means · H2S exposure limits · bump test vs calibration · how to read a gas monitor alarm · what Class I Div 1 means · sensor life · every gas monitor by gas, sampling and battery · GX-3R vs GX-3R Pro · how to calibrate a GX-Force or GX-3R Pro.
Manufacturer item number: 72-PJX-D. Datasheet: RKI Instruments GX-3R Pro datasheet (PDF).
The RKI 72-PJX-D is a GX-3R Pro 2-gas personal gas monitor configured to detect combustible gas (LEL) and hydrogen sulfide (H2S). This configuration ships with a lithium-ion battery pack and a 12 VDC vehicle charger. The GX-3R Pro is RKI's smallest and lightest 5-gas personal monitor, with Bluetooth communication to the iOS/Android app, a man-down alarm, a non-compliance indicator and field-replaceable sensors and filters.
Item number: 72-PJX-D. Sold individually. Warranty: 3 years. Country of origin: Japan.
More information on the RKI GX-3R Pro page | Watch the product video