Portwest FR Coats & Jackets
17 FR coats & jackets from Portwest, listed with what Portwest publishes, and current prices.
Pick a arc rating band, material or hi-vis class; the list below narrows as you choose. Prices shown are current.

17 garments
Ratings and specifications are as published by each manufacturer. Tap a group to open it.
Portwest17 garments
- Portwest Bizflame 88/12 FR612 FR Parkas, ATPV 56 cal/cm², CAT 4 — Portwest · Arc rating: 56 cal/cm2 · PPE category: CAT 4 · Material: 88% Cotton, 12% Nylon · Fabric weight: 9 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 56 cal/cm2; CSA Z96 Class 1 Level FR
- Portwest Bizflame Duck UFR48 FR Insulated Jackets, ATPV 45 cal/cm², CAT 4 — Portwest · Arc rating: 45 cal/cm2 · PPE category: CAT 4 · Material: 100% Cotton Duck · Fabric weight: 10 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 45 cal/cm2
- Portwest Bizflame Industry FR68 FR Jackets, ATPV 16 cal/cm², EN ISO 11612 — Portwest · Arc rating: 16 cal/cm2 · PPE category: CAT 2 · Material: 80% Cotton, 19% Polyester, 1% Carbon Fiber · Fabric weight: 10 oz · Standards: ASTM F1959 ATPV 16 cal/cm2 (HAF 83.7%); IEC 61482-2 IEC 61482-1-2 Class 1; IEC 61482-2 IEC 61482-1-2 APC 1; EN ISO 11612 A1+A2, B1, C1, E2, F1; EN ISO 11611 Class 1 A1+A2; EN 1149-5; EN 13034 Type PB [6]
- Portwest Bizflame Knit FR708 FR Sweatshirts, ATPV 22 cal/cm², CAT 2 — Portwest · Arc rating: 22 cal/cm2 · PPE category: CAT 2 · Material: 100% Cotton · Fabric weight: 12 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 22 cal/cm2; UPF 40+
- Portwest Bizflame Knit FR726 FR Sweatshirts, ATPV 24 cal/cm², CAT 2 — Portwest · Arc rating: 24 cal/cm2 · PPE category: CAT 2 · Material: 100% Cotton · Fabric weight: 10 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 24 cal/cm2
- Portwest Bizflame Knit FR747 FR Hooded Sweatshirts, ATPV 24 cal/cm², CAT 2 — Portwest · Arc rating: 24 cal/cm2 · PPE category: CAT 2 · Material: 100% Cotton · Fabric weight: 10 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 24 cal/cm2; CSA Z96 Class 1 Level FR; UPF 40+
- Portwest Bizflame Knit FR760 FR Sweatshirts, ATPV 24 cal/cm², CAT 2 — Portwest · Arc rating: 24 cal/cm2 · PPE category: CAT 2 · Material: 100% Cotton · Fabric weight: 10 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 24 cal/cm2
- Portwest Bizflame Work FR25 FR Jackets, ATPV 13.6 cal/cm², EN ISO 11612 — Portwest · Arc rating: 13.6 cal/cm2 · PPE category: CAT 2 · Material: 99% Cotton, 1% Carbon Fiber · Fabric weight: 10 oz · Standards: ASTM F1959 ATPV 13.6 cal/cm2 (HAF 82%); IEC 61482-2 IEC 61482-1-2 Class 1; EN ISO 11612 A1+A2, B1, C1, E2, F1; EN ISO 11611 Class 2 A1+A2; EN 1149-5; UPF 50+
- Portwest Bizflame Work FR610 FR Parkas, ATPV 40 cal/cm², CAT 4 — Portwest · Arc rating: 40 cal/cm2 · PPE category: CAT 4 · Material: 99% Cotton, 1% Carbon Fibre · Fabric weight: 10 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 40 cal/cm2
- Portwest IAS3215 FR Parkas, ATPV 61 cal/cm², NFPA 2112 — Portwest · Arc rating: 61 cal/cm2 · PPE category: CAT 4 · Material: 88% FR Cotton, 12% Nylon · Fabric weight: 9 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 61 cal/cm2; CSA Z462; CGSB 155.20; CSA Z96 Class 1 Level FR
- Portwest IFR IOS324 FR Fleece Jackets, ATPV 23 cal/cm², CAT 2 — Portwest · Arc rating: 23 cal/cm2 · PPE category: CAT 2 · Material: 55% Modacrylic, 45% Cotton · Fabric weight: 14 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 23 cal/cm2; CSA Z462; CGSB 155.20
- Portwest IFR IOS375 Women's FR Fleece Jackets, ATPV 23 cal/cm², CAT 2 — Portwest · Arc rating: 23 cal/cm2 · PPE category: CAT 2 · Material: 55% Modacrylic, 45% Cotton · Fabric weight: 14 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 23 cal/cm2; CSA Z462; CGSB 155.20
- Portwest IFR IUS215 FR Parkas, ATPV 61 cal/cm², NFPA 2112 — Portwest · Arc rating: 61 cal/cm2 · PPE category: CAT 4 · Material: 88% FR Cotton, 12% Nylon · Fabric weight: 9 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 61 cal/cm2; CSA Z462; CGSB 155.20; CSA Z96 Class 1 Level FR
- Portwest IFR IUS515 FR Hi-Vis Parkas, ATPV 61 cal/cm², NFPA 2112 — Portwest · Arc rating: 61 cal/cm2 · PPE category: CAT 4 · Material: 88% FR Cotton, 12% Nylon · Fabric weight: 9 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 61 cal/cm2; CSA Z462; CGSB 155.20; CSA Z96 Class 2 Level 2
- Portwest Modaflame UFR81 FR Sweatshirts, ATPV 16 cal/cm², EN ISO 11612 — Portwest · Arc rating: 16 cal/cm2 · PPE category: CAT 2 · Material: 60% Modacrylic, 39% Cotton, 1% Carbon Fiber · Fabric weight: 9 oz · Standards: ASTM F1959 ATPV 16 cal/cm2; IEC 61482-2 IEC 61482-1-2 APC 1; IEC 61482-2 IEC 61482-1-1 ELIM 9.2 cal/cm2, ATPV 15 cal/cm2; EN ISO 11612 A1, B1, C1, F1; EN 1149-5; UPF 40+
- Portwest Sealtex Flame FR41 FR Hi-Vis Rain Jackets, Type R Class 3, EN 343 3:1:X — Portwest · Material: 100% Polyester, PU Coated · Fabric weight: 7.5 oz · Hi-vis class: Class 3 · Standards: EN ISO 14116 Index 1; EN 1149-5; EN 13034 Type 6; ANSI/ISEA 107-2015 Type R and Type P Class 3; EN ISO 20471 Class 3; EN 343 Class 3:1:X
- Portwest Sealtex Flame FR44 FR Hi-Vis Rain Coats, Type R Class 3, EN 343 3:1:X — Portwest · Material: 100% Polyester, PU Coated · Fabric weight: 7.5 oz · Hi-vis class: Class 3 · Standards: EN ISO 14116 Index 1; EN 1149-5; EN 13034 Type 6; ANSI/ISEA 107-2015 Type R Class 3; EN ISO 20471 Class 3; EN 343 Class 3:1:X
Do not see what you need? Browse the category or call (925) 215-7337.
In plain words. An arc rating is the amount of heat energy, in calories per square centimetre, that a fabric blocked before the test predicted a second-degree burn; it is printed on the garment label as ATPV or EBT. NFPA 70E groups PPE into categories by the minimum rating: Category 1 needs 4 cal/cm², Category 2 8, Category 3 25, Category 4 40. Flame resistance (the fabric self-extinguishes) is a separate test from the arc rating; a garment can be FR without an arc rating. Every number here is the manufacturer's.
Technical. Arc ratings by ASTM F1959 (reported as ATPV, or EBT where the fabric breaks open first); FR garment performance by ASTM F1506 (electric arc) and NFPA 2112 (flash fire, with NFPA 2113 for selection); NFPA 70E Table 130.7(C)(15)(c) sets the PPE categories by incident energy. Hi-vis FR garments also carry an ANSI/ISEA 107 class. Fabric weights are in ounces per square yard as published.
Ratings and specifications on this page are shown as published by the manufacturer or the named standard and describe performance in that standard's test. They are not a recommendation for any task. The employer's hazard assessment decides what protective equipment a job needs. Verify details against the manufacturer's current documentation before you buy.
The standard at a glance
Copied from the named standard or regulation and shown with its source; nothing in these tables is Bayshore's recommendation.
NFPA 70E PPE categories
| PPE category | Minimum arc rating of the clothing system |
|---|---|
| Category 1 | 4 cal/cm² |
| Category 2 | 8 cal/cm² |
| Category 3 | 25 cal/cm² |
| Category 4 | 40 cal/cm² |
Source: NFPA 70E, Table 130.7(C)(15)(c). Arc ratings (ATPV or EBT) tested to ASTM F1959; FR garments to ASTM F1506 and NFPA 2112.