Single-Gas Monitors with Alkaline Batteries
16 single-gas monitors with alkaline batteries from every brand we carry, listed with what each manufacturer publishes, and live prices.
Pick a brand, gas, number of gases or sampling; the list below narrows as you choose. Prices are live.

16 products
Ratings and specifications are as published by each manufacturer. Tap a group to open it.
RKI Instruments16 products
- RKI Instruments 72-POX-A Single Gas Monitors, GX-3R Pro Single-Gas Monitor LEL — RKI Instruments · Gases detected: LEL · Gases: 1 gas · Sampling: Diffusion · Battery: Alkaline · Sensor ranges: LEL 0-100% LEL · Approvals: ATEX, CSA, IECEx, MED (CSA C/US intrinsically safe Class I Div 1 Groups A, B, C, D, T4)
- RKI Instruments 72-PPX-A Single Gas Monitors, GX-3R Pro Single-Gas Monitor O2 — RKI Instruments · Gases detected: O2 · Gases: 1 gas · Sampling: Diffusion · Battery: Alkaline · Sensor ranges: O2 0-40% vol · Approvals: ATEX, CSA, IECEx, MED (CSA C/US intrinsically safe Class I Div 1 Groups A, B, C, D, T4)
- RKI Instruments 72-PQX-A Single Gas Monitors, GX-3R Pro Single-Gas Monitor H2S — RKI Instruments · Gases detected: H2S · Gases: 1 gas · Sampling: Diffusion · Battery: Alkaline · Sensor ranges: H2S 0-200 ppm · Approvals: ATEX, CSA, IECEx, MED (CSA C/US intrinsically safe Class I Div 1 Groups A, B, C, D, T4)
- RKI Instruments 72-PRX-A Single Gas Monitors, GX-3R Pro Single-Gas Monitor CO — RKI Instruments · Gases detected: CO · Gases: 1 gas · Sampling: Diffusion · Battery: Alkaline · Sensor ranges: CO 0-2,000 ppm · Approvals: ATEX, CSA, IECEx, MED (CSA C/US intrinsically safe Class I Div 1 Groups A, B, C, D, T4)
- RKI Instruments 72-PSX-A Single Gas Monitors, GX-3R Pro Single-Gas Monitor CO — RKI Instruments · Gases detected: CO · Gases: 1 gas · Sampling: Diffusion · Battery: Alkaline · Sensor ranges: CO 0-2,000 ppm (H2-compensated CO sensor) · Approvals: ATEX, CSA, IECEx, MED (CSA C/US intrinsically safe Class I Div 1 Groups A, B, C, D, T4)
- RKI Instruments 72-PXA-A Single Gas Monitors, GX-3R Pro Single-Gas Monitor — RKI Instruments · Gases detected: CO2 · Gases: 1 gas · Sampling: Diffusion · Battery: Alkaline · Sensor ranges: CO2 0-10% vol · Approvals: ATEX, CSA, IECEx, MED (CSA C/US intrinsically safe Class I Div 1 Groups A, B, C, D, T4)
- RKI Instruments 72-PXB-A Single Gas Monitors, GX-3R Pro Single-Gas Monitor CO2 % — RKI Instruments · Gases detected: CO2 · Gases: 1 gas · Sampling: Diffusion · Battery: Alkaline · Sensor ranges: CO2 0-10% vol · Approvals: ATEX, CSA, IECEx, MED (CSA C/US intrinsically safe Class I Div 1 Groups A, B, C, D, T4)
- RKI Instruments 72-PXC-A Single Gas Monitors, GX-3R Pro Single-Gas Monitor SO2 — RKI Instruments · Gases detected: SO2 · Gases: 1 gas · Sampling: Diffusion · Battery: Alkaline · Sensor ranges: SO2 0-100 ppm · Approvals: ATEX, CSA, IECEx, MED (CSA C/US intrinsically safe Class I Div 1 Groups A, B, C, D, T4)
- RKI Instruments 73-0063 Single Gas Monitors, HS-04 Single-Gas Monitor H2S — RKI Instruments · Gases detected: H2S · Gases: 1 gas · Sampling: Diffusion · Battery: Alkaline · Approvals: CSA
- RKI Instruments 73-0065 Single Gas Monitors, CO-04 Single-Gas Monitor CO — RKI Instruments · Gases detected: CO · Gases: 1 gas · Sampling: Diffusion · Battery: Alkaline · Approvals: CSA
- RKI Instruments 73-0067 Single Gas Monitors, CO-04C Single-Gas Monitor CO — RKI Instruments · Gases detected: CO · Gases: 1 gas · Sampling: Diffusion · Battery: Alkaline · Sensor ranges: CO sensor H2-compensated · Approvals: CSA
- RKI Instruments 73-0071 Single Gas Monitors, SC-04 Single-Gas Monitor HCN — RKI Instruments · Gases detected: HCN · Gases: 1 gas · Sampling: Diffusion · Battery: Alkaline · Approvals: CSA
- RKI Instruments 73-0073 Single Gas Monitors, SC-04 Single-Gas Monitor NO2 — RKI Instruments · Gases detected: NO2 · Gases: 1 gas · Sampling: Diffusion · Battery: Alkaline · Approvals: CSA
- RKI Instruments 73-0077 Single Gas Monitors, SC-04 Single-Gas Monitor NH3 — RKI Instruments · Gases detected: NH3 · Gases: 1 gas · Sampling: Diffusion · Battery: Alkaline · Approvals: CSA
- RKI Instruments 73-0079 Single Gas Monitors, SC-04 Single-Gas Monitor PH3 — RKI Instruments · Gases detected: PH3 · Gases: 1 gas · Sampling: Diffusion · Battery: Alkaline · Approvals: CSA
- RKI Instruments 73-0081 Single Gas Monitors, SC-04 Single-Gas Monitor SO2 — RKI Instruments · Gases detected: SO2 · Gases: 1 gas · Sampling: Diffusion · Battery: Alkaline · Approvals: CSA
Do not see what you need? Browse the category or call (925) 215-7337.
In plain words. A gas monitor is described by the gases it detects (LEL for combustibles, O2 for oxygen, H2S, CO, and so on), how many it detects at once, whether it samples by diffusion (air reaches the sensors on its own) or with a pump (sample draw, for checking a space before entry), how it is powered, and the approvals that let it be used in a classified area. All of these are the manufacturer's published specifications; alarm points and calibration intervals follow the manufacturer's manual.
Technical. Intrinsic-safety approvals are listed as the manufacturer prints them (UL or CSA Class I Division 1 Groups A–D, ATEX and IECEx Ex ia IIC T4 marks). Sensor ranges are quoted per gas (for example 0–100% LEL, 0–30% volume O2, 0–100 ppm H2S, 0–500 ppm CO; PID sensors for VOCs in ppm or ppb with the lamp energy in eV; IR sensors for CO2 or methane). Calibration gas is matched to the monitor's sensors and listed by concentration. Draeger detector tubes have their own finder page.
Ratings and specifications on this page are shown as published by the manufacturer or the named standard and describe performance in that standard's test. They are not a recommendation for any task. The employer's hazard assessment decides what protective equipment a job needs. Verify details against the manufacturer's current documentation before you buy.
The standard at a glance
Copied from the named standard or regulation and shown with its source; nothing in these tables is Bayshore's recommendation.
OSHA confined-space atmosphere limits
| Condition (29 CFR 1910.146) | Limit |
|---|---|
| Oxygen deficient | Below 19.5% oxygen |
| Oxygen enriched | Above 23.5% oxygen |
| Flammable | Above 10% of the lower flammable limit (LFL) |
| Toxic | Above the substance's permissible exposure limit (29 CFR 1910 Subpart Z) |
| Approval mark (as printed by the manufacturer) | Meaning |
|---|---|
| UL or CSA Class I, Division 1, Groups A–D | Intrinsically safe for flammable gas and vapour atmospheres (North America) |
| ATEX / IECEx Ex ia IIC T4 | Intrinsically safe, gas group IIC, temperature class T4 (Europe / international) |
Source: OSHA 29 CFR 1910.146 (permit-required confined spaces). Alarm set points and calibration intervals follow each manufacturer's manual. Draeger detector tubes have their own finder.