Skip to main content
Gas Detection Finder · 1,400 products, every brand we carry

Gas Detection Finder

1,400 gas detection products from every brand we carry, in one list with live prices. Pick a type, a rating or a brand; every selection is its own page.

Pick a type, brand, gas, number of gases, sampling or battery; the list below narrows as you choose. Prices are live.

MSA 10020541 Gas Monitor Accessories, Plastic Sirius Carrying Case For Sirius

1,400 products

Ratings and specifications are as published by each manufacturer. Tap a group to open it.

1-gas monitors153 products

And 93 more in this group; use the selector or the group's own page.

2-gas monitors189 products

And 129 more in this group; use the selector or the group's own page.

3-gas monitors195 products

And 135 more in this group; use the selector or the group's own page.

4-gas monitors200 products

And 140 more in this group; use the selector or the group's own page.

5-gas monitors108 products

And 48 more in this group; use the selector or the group's own page.

6-gas monitors85 products

And 25 more in this group; use the selector or the group's own page.

Batteries & Chargers47 products

Open the Batteries & Chargers page

Breathing Air Testing14 products

Open the Breathing Air Testing page

Calibration Gas & Kits88 products

Open the Calibration Gas & Kits page

And 28 more in this group; use the selector or the group's own page.

Detector Tubes & Pumps31 products

Open the Detector Tubes & Pumps page

Gas Monitor Accessories136 products

And 76 more in this group; use the selector or the group's own page.

Multi-Gas Detectors8 products
Other2 products
Replacement Parts53 products
Replacement Sensors88 products

Open the Replacement Sensors page

And 28 more in this group; use the selector or the group's own page.

Single-Gas Monitors3 products

Do not see what you need? Browse the category or call (925) 215-7337.

Browse by type

Browse by brand and type

Browse by number of gases

Browse by battery and type

In plain words. A gas monitor is described by the gases it detects (LEL for combustibles, O2 for oxygen, H2S, CO, and so on), how many it detects at once, whether it samples by diffusion (air reaches the sensors on its own) or with a pump (sample draw, for checking a space before entry), how it is powered, and the approvals that let it be used in a classified area. All of these are the manufacturer's published specifications; alarm points and calibration intervals follow the manufacturer's manual.

Technical. Intrinsic-safety approvals are listed as the manufacturer prints them (UL or CSA Class I Division 1 Groups A–D, ATEX and IECEx Ex ia IIC T4 marks). Sensor ranges are quoted per gas (for example 0–100% LEL, 0–30% volume O2, 0–100 ppm H2S, 0–500 ppm CO; PID sensors for VOCs in ppm or ppb with the lamp energy in eV; IR sensors for CO2 or methane). Calibration gas is matched to the monitor's sensors and listed by concentration. Draeger detector tubes have their own finder page.

Ratings and specifications on this page are shown as published by the manufacturer or the named standard and describe performance in that standard's test. They are not a recommendation for any task. The employer's hazard assessment decides what protective equipment a job needs. Verify details against the manufacturer's current documentation before you buy.

The standard at a glance

Copied from the named standard or regulation and shown with its source; nothing in these tables is Bayshore's recommendation.

OSHA confined-space atmosphere limits
Condition (29 CFR 1910.146)Limit
Oxygen deficientBelow 19.5% oxygen
Oxygen enrichedAbove 23.5% oxygen
FlammableAbove 10% of the lower flammable limit (LFL)
ToxicAbove the substance's permissible exposure limit (29 CFR 1910 Subpart Z)
Approval mark (as printed by the manufacturer)Meaning
UL or CSA Class I, Division 1, Groups A–DIntrinsically safe for flammable gas and vapour atmospheres (North America)
ATEX / IECEx Ex ia IIC T4Intrinsically safe, gas group IIC, temperature class T4 (Europe / international)

Source: OSHA 29 CFR 1910.146 (permit-required confined spaces). Alarm set points and calibration intervals follow each manufacturer's manual. Draeger detector tubes have their own finder.

Need help choosing?Call us with the job and the hazard; we will point you at the products the manufacturers rate for it.
Call (925) 215-7337
Corporate AccountsContract pricing and inventory management available.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.