FR Coveralls & Overalls
48 FR coveralls & overalls from every brand we carry, listed with what each manufacturer publishes, and live prices.
Pick a arc rating band, brand, material or hi-vis class; the list below narrows as you choose. Prices are live.

48 garments
Ratings and specifications are as published by each manufacturer. Tap a group to open it.
Portwest20 garments
- Portwest FR422 Arc Flash Pants & Bibs, Bizflame Work Insulated FR Bib Overall — Portwest · Arc rating: 40 cal/cm2 · PPE category: CAT 4 · Material: Bizflame Work: 99% Cotton, 1% Carbon Fiber; Lining: 100% FR Cotton; Filling: 90% Modacrylic, 10% Aramid · Fabric weight: 10 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 40 cal/cm2
- Portwest FR504 Bizflame Women's FR Coverall — Portwest · Arc rating: 8.2 cal/cm2 · PPE category: CAT 2 · Material: Bizflame 88/12: 88% Cotton, 12% Nylon · Fabric weight: 7 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 8.2 cal/cm2
- Portwest FR505 Bizflame ARC FR Coverall — Portwest · Arc rating: 34 cal/cm2 (HAF 91.9%) · Material: Bizflame 88/12: 88% Cotton, 12% Nylon · Fabric weight: 14 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959/F1959M-12 ATPV 34 cal/cm2 (HAF 91.9%)
- Portwest FR510 Arc Flash Coveralls, Bizflame X Back 2” Iona FR Coverall — Portwest · Arc rating: 8.2 cal/cm2 · PPE category: CAT 2 · Material: Bizflame 88/12: 88% Cotton, 12% Nylon · Fabric weight: 7 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 8.2 cal/cm2; CSA Z96 Class 3 Level 2
- Portwest FR511 Arc Flash Coveralls, Bizflame X Back 2” Iona Xtra FR Coverall — Portwest · Arc rating: 8.2 cal/cm2 (HAF 69.1%) · Material: Bizflame 88/12: 88% Cotton, 12% Nylon · Fabric weight: 7 oz · Standards: CSA Z96 Class 1 Level FR; NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959/F1959M-12 ATPV 8.2 cal/cm2 (HAF 69.1%)
- Portwest FR514 Arc Flash Coveralls, Bizflame Work Insulated FR Coverall — Portwest · Arc rating: 40 cal/cm2 · PPE category: CAT 4 · Material: Bizflame Work: 99% Cotton, 1% Carbon Fiber; Lining: 100% FR Cotton; Filling: 90% Modacrylic, 10% Aramid · Fabric weight: 10 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 40 cal/cm2
- Portwest FR518 FR Coveralls, Bizflame Work Lightweight FR NFPA — Portwest · Arc rating: 8.5 cal/cm2 · PPE category: CAT 2 · Material: Bizflame Work: 99% Cotton, 1% Carbon Fiber · Fabric weight: 7 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 8.5 cal/cm2; EN 1149-5; EN 17353 Type B2
- Portwest FR525 Arc Flash Coveralls, Bizflame 2" Xtra FR Coverall — Portwest · Arc rating: 8.2 cal/cm2 · PPE category: CAT 2 · Material: Bizflame 88/12: 88% Cotton, 12% Nylon · Fabric weight: 7 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 8.2 cal/cm2; CSA Z96 Class 1 Level FR
- Portwest FR94 Bizflame Iona FR Coverall — Portwest · Arc rating: 8.2 cal/cm2 · PPE category: CAT 2 · Material: Bizflame 88/12: 88% Cotton, 12% Nylon · Fabric weight: 7 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 8.2 cal/cm2
- Portwest IAS3108 Arc Flash Coveralls, Avenger 7oz Coverall — Portwest · Arc rating: 8.9 cal/cm2 · Material: 88% FR Cotton, 12% Nylon · Fabric weight: 7 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; CGSB 155.20; CSA Z462; CSA Z96 Class 1 Level FR; ASTM F1959 ATPV 8.9 cal/cm2
- Portwest IDHS109 Arc Flash Coveralls, Westex DH Antistat 6.5oz Deluxe Coverall — Portwest · Arc rating: 8.9 cal/cm2 · Material: Westex: 48% Lenzing Lyocell, 39% Modacrylic, 12% Aramid, 1% Carbon Fiber · Fabric weight: 6.5 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; CGSB 155.20; CSA Z462; CSA Z96 Class 1 Level FR; NFPA 1975; NFPA 1977; ASTM F1959 ATPV 8.9 cal/cm2
- Portwest INS109 Arc Flash Coveralls, Nomex Essential 6oz Deluxe Coverall — Portwest · Arc rating: 6 cal/cm2 · Material: Nomex: 93% Nomex Essential, 5% Kevlar, 2% Carbon Fiber · Fabric weight: 6 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; CGSB 155.20; CGSB 155.22; CSA Z462; CSA Z96 Class 1 Level FR; NFPA 1977; ASTM F1959 ATPV 6 cal/cm2
- Portwest IUS102 Arc Flash Coveralls, Ultrasoft 7oz Deluxe Coverall — Portwest · Arc rating: 8.7 cal/cm2 · Material: Westex: 88% FR Cotton, 12% Nylon · Fabric weight: 7 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; CGSB 155.20; CSA Z462; CSA Z96 Class 1 Level FR; ASTM F1959 ATPV 8.7 cal/cm2
- Portwest UBIZ1 Bizweld Work FR Coverall — Portwest · Arc rating: 11.2 cal/cm2 · PPE category: CAT 2 · Material: Bizweld Work: 100% Cotton · Fabric weight: 9.5 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 11.2 cal/cm2; EN ISO 11612 A1+A2, B1, C1, E2, F1; EN ISO 11611 Class 1 A1+A2
- Portwest UBIZ5 Bizweld Work Iona FR Coverall — Portwest · Arc rating: 11.2 cal/cm2 (HAF 80.4%) · PPE category: CAT 2 · Material: Bizweld Work: 100% Cotton · Fabric weight: 9.5 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959/F1959M-12 ATPV 11.2 cal/cm2 (HAF 80.4%); EN ISO 11612 A1+A2, B1, C1, E2, F1; EN ISO 11611 Class 1 A1+A2
- Portwest UBIZ8 Bizweld Work Taped FR Coverall — Portwest · Arc rating: 11.2 cal/cm2 · PPE category: CAT 2 · Material: Bizweld Work: 100% Cotton · Fabric weight: 9.5 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 11.2 cal/cm2; EN ISO 11612 A1+A2, B1, C1, E2, F1; EN ISO 11611 Class 1 A1+A2
- Portwest UFR21 FR Coveralls, Bizflame Work Super Lightweight — Portwest · Arc rating: 8.5 cal/cm2 · PPE category: CAT 2 · Material: Bizflame Work: 99% Cotton, 1% Carbon Fiber · Fabric weight: 7 oz · Standards: NFPA 70E; ASTM F1506; ASTM F1959 ATPV 8.5 cal/cm2; EN 1149-5
- Portwest UFR49 Arc Flash Pants & Bibs, DuraDuck Flame Quilt Lined FR Bib Overall — Portwest · Arc rating: 45 cal/cm2 · PPE category: CAT 4 · Material: Bizflame Duck: 100% Cotton Duck; Lining: 100% FR Cotton; Filling: 90% Modacrylic, 10% Aramid · Fabric weight: 10 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 45 cal/cm2
- Portwest UFR87 Bizflame Classic FR Coverall — Portwest · Arc rating: 8.2 cal/cm2 · PPE category: CAT 2 · Material: Bizflame 88/12: 88% Cotton, 12% Nylon · Fabric weight: 7 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 8.2 cal/cm2
- Portwest UFR88 Bizflame FR Coverall — Portwest · Arc rating: 8.2 cal/cm2 (HAF 69.1%) · PPE category: CAT 2 · Material: Bizflame 88/12: 88% Cotton, 12% Nylon · Fabric weight: 7 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959/F1959M-12 ATPV 8.2 cal/cm2 (HAF 69.1%); EN ISO 11612 A1+A2, B1, C1
MCR Safety12 garments
- MCR Safety BLCVTCN FR Coveralls, FR Gear — MCR Safety · Arc rating: 9.1 cal/cm2
- MCR Safety CCMG FR Coveralls, FR Gear — MCR Safety · Arc rating: 8.7 cal/cm2
- MCR Safety CCMN FR Coveralls, FR Gear — MCR Safety · Arc rating: 8.7 cal/cm2
- MCR Safety CCMR FR Coveralls, Red Flame Resistant Contractor — MCR Safety
- MCR Safety CCMT FR Coveralls, FR Gear — MCR Safety · Arc rating: 8.7 cal/cm2
- MCR Safety SBC1011 FR Coveralls, Summit Breeze Flame Resistant (FR) — MCR Safety
- MCR Safety SBC1012 FR Coveralls, Summit Breeze Flame Resistant (FR) — MCR Safety
- MCR Safety SBC1032 FR Coveralls, Summit Breeze Flame Resistant (FR) — MCR Safety
- MCR Safety SBC2011 FR Coveralls, Summit Breeze Flame Resistant (FR) — MCR Safety
- MCR Safety SBC2012 FR Coveralls, Summit Breeze Flame Resistant (FR) — MCR Safety
- MCR Safety SBC2031 FR Coveralls, Summit Breeze Flame Resistant (FR) — MCR Safety
- MCR Safety SBC2035 FR Coveralls, Summit Breeze Flame Resistant (FR) — MCR Safety
Radians5 garments
- Radians FRCA-001 Arc Flash Coveralls, VolCore Cotton/Nylon FR Coverall — Radians · PPE category: CAT 2 · Material: Mesh
- Radians FRCA-002 Arc Flash Coveralls, VolCore Cotton FR Coverall — Radians · PPE category: CAT 2
- Radians FRCA-003 Arc Flash Coveralls, VolCore Cotton FR Coverall — Radians · PPE category: CAT 2
- Radians FRCA-004 Arc Flash Coveralls, VolCore Cotton FR Coverall — Radians · PPE category: CAT 2
- Radians FRCA-WCA Arc Flash Coveralls, VolCore Welding Front Snap Coverall — Radians · PPE category: CAT 2
Bisley2 garments
- Bisley Performance 385MFRHC Arc Flash Coveralls, Dual-Certified AR/FR Ripstop — Bisley · Arc rating: 8.9 cal/cm2 · Material: Aramid Blend; Modacrylic · Fabric weight: Lightweight · Hi-vis class: Class 2 · Standards: NFPA 70E; NFPA 2112; UL Certified; ASTM F1506
- Bisley Performance 385WFRHC Arc Flash Coveralls, Dual-Certified AR/FR Women's — Bisley · Arc rating: 8.9 cal/cm2 · PPE category: CAT 2 · Material: Aramid Blend; Cotton · Fabric weight: Lightweight · Hi-vis class: Class 2 · Standards: NFPA 70E; NFPA 2112; UL Certified; ASTM F1506
DuPont ProShield2 garments
- DuPont ProShield 6 SFR Coveralls — DuPont ProShield · Material: ProShield 6 SFR
- DuPont ProShield TM127SBU2X002500 FR Coveralls, Blue — DuPont ProShield · Material: ProShield 6 SFR
Neese2 garments
- Neese VI9CAENV Arc Flash Coveralls, VI9CAE 9 oz Indura FR Extrication Coverall — Neese · PPE category: CAT 2
- Neese VM7CA3FY Arc Flash Coveralls, VM7CA3 Modacrylic High Visibility FR — Neese · PPE category: CAT 2
Stanco2 garments
- Stanco FRC681NB Arc Flash Coveralls, FR Cotton Coverall 7.5 oz, Navy — Stanco · Arc rating: 8 cal/cm2 · PPE category: CAT 2 · Material: Cotton · Standards: NFPA 2112; NFPA 70E
- Stanco FRC681TN Arc Flash Coveralls, 681 Full-Featured Contractor Style FR — Stanco · Material: FR Cotton · Fabric weight: 7.5 oz
Bulwark1 garment
- Bulwark CLD4NVRG48 Arc Flash Coveralls, CLD4 EXCEL FR ComforTouch Deluxe, Navy — Bulwark · Arc rating: 9.1 cal/cm2 · Material: EXCEL FR ComforTouch Sateen
Cordova Safety1 garment
- Cordova Safety FRC150 FR Coveralls, Defender FR Disposable Flame — Cordova Safety · Standards: NFPA 701
International Enviroguard1 garment
- International Enviroguard 9019 FR Coveralls, PyroGuard FR — International Enviroguard · Material: FR-Treated Nonwoven · Standards: ASTM D6413; EN 1149-5; ASTM D5034
Do not see what you need? Browse the category or call (925) 215-7337.
In plain words. An arc rating is the amount of heat energy, in calories per square centimetre, that a fabric blocked before the test predicted a second-degree burn; it is printed on the garment label as ATPV or EBT. NFPA 70E groups PPE into categories by the minimum rating: Category 1 needs 4 cal/cm², Category 2 8, Category 3 25, Category 4 40. Flame resistance (the fabric self-extinguishes) is a separate test from the arc rating; a garment can be FR without an arc rating. Every number here is the manufacturer's.
Technical. Arc ratings by ASTM F1959 (reported as ATPV, or EBT where the fabric breaks open first); FR garment performance by ASTM F1506 (electric arc) and NFPA 2112 (flash fire, with NFPA 2113 for selection); NFPA 70E Table 130.7(C)(15)(c) sets the PPE categories by incident energy. Hi-vis FR garments also carry an ANSI/ISEA 107 class. Fabric weights are in ounces per square yard as published.
Ratings and specifications on this page are shown as published by the manufacturer or the named standard and describe performance in that standard's test. They are not a recommendation for any task. The employer's hazard assessment decides what protective equipment a job needs. Verify details against the manufacturer's current documentation before you buy.
The standard at a glance
Copied from the named standard or regulation and shown with its source; nothing in these tables is Bayshore's recommendation.
NFPA 70E PPE categories
| PPE category | Minimum arc rating of the clothing system |
|---|---|
| Category 1 | 4 cal/cm² |
| Category 2 | 8 cal/cm² |
| Category 3 | 25 cal/cm² |
| Category 4 | 40 cal/cm² |
Source: NFPA 70E, Table 130.7(C)(15)(c). Arc ratings (ATPV or EBT) tested to ASTM F1959; FR garments to ASTM F1506 and NFPA 2112.