PIP 9100-524ULT Arc Flash Jackets, AR/FR Ultralight Jacket, 40 Cal/cm2

31 garments

Ratings and specifications are as published by each manufacturer. Tap a group to open it.

Arc Flash Clothing9 garments

Open the Arc Flash Clothing page

Coats & Jackets7 garments
  • Bisley Performance 385M8387H Arc Flash Jackets, Dual-Certified AR/FR Ripstop — Bisley · Arc rating: 40 cal/cm2 · PPE category: CAT 4 · Material: Cellulose; Modacrylic · Hi-vis class: Class 3 · Standards: NFPA 70E; NFPA 2112; UL Certified; ASTM F1506
  • Portwest FR610 Arc Flash Jackets, Bizflame Work Insulated FR Parka — Portwest · Arc rating: 40 cal/cm2 · PPE category: CAT 4 · Material: Bizflame Work: 99% Cotton, 1% Carbon Fiber; Lining: 100% FR Cotton; Filling: 90% Modacrylic, 10% Aramid · Fabric weight: 10 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 40 cal/cm2
  • Portwest FR612 FR Jackets, Bizflame X-Back Insulated FR Winter Parka — Portwest · Arc rating: 56 cal/cm2 · PPE category: CAT 4 · Material: Bizflame 88/12: 88% Cotton, 12% Nylon; Lining: 100% FR Polyester with transparent FR PU coating; Lining: 100% FR Cotton quilted to 100% Modacrylic Wadding · Fabric weight: 9 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 56 cal/cm2; CSA Z96 Class 1 Level FR
  • Portwest IAS3215 Arc Flash Jackets, Avenger 9oz Insulated Parka — Portwest · Arc rating: 61 cal/cm2 · Material: 88% FR Cotton, 12% Nylon; Lining: Westex: 88% FR Cotton, 12% Nylon; Filling: Westex FR Modacrylic Insulation · Fabric weight: 9 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; CGSB 155.20; CSA Z462; CSA Z96 Class 1 Level FR; ASTM F1959 ATPV 61 cal/cm2
  • Portwest IUS215 Arc Flash Jackets, Ultrasoft 9oz Insulated Parka — Portwest · Arc rating: 61 cal/cm2 · Material: Westex: 88% FR Cotton, 12% Nylon; Lining: Westex: 88% FR Cotton, 12% Nylon; Filling: Westex FR Modacrylic Insulation · Fabric weight: 9 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; CGSB 155.20; CSA Z462; CSA Z96 Class 1 Level FR; ASTM F1959 ATPV 61 cal/cm2
  • Portwest IUS515 Arc Flash Jackets, Ultrasoft 9oz Hi-Vis Insulated Parka — Portwest · Arc rating: 61 cal/cm2 · Material: Westex: 88% FR Cotton, 12% Nylon; Filling: Westex: 88% FR Cotton, 12% Nylon · Fabric weight: 9 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; CGSB 155.20; CSA Z462; CSA Z96 Class 2 Level 2; ASTM F1959 ATPV 61 cal/cm2
  • Portwest UFR48 Arc Flash Jackets, DuraDuck Flame Quilt Lined FR Jacket — Portwest · Arc rating: 45 cal/cm2 · PPE category: CAT 4 · Material: Bizflame Duck: 100% Cotton Duck; Lining: 100% FR Cotton; Filling: 90% Modacrylic, 10% Aramid · Fabric weight: 10 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 45 cal/cm2
Arc Flash Accessories4 garments
Pants & Bibs4 garments
  • Portwest FR429 Bizflame Insulated FR Winter Bib Pants — Portwest · Arc rating: 56 cal/cm2 · PPE category: CAT 4 · Material: Bizflame 88/12: 88% Cotton, 12% Nylon; Lining: 100% FR Polyester with transparent FR PU coating; Lining: 100% FR Cotton quilted to 100% Modacrylic Wadding · Fabric weight: 9 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 56 cal/cm2; CSA Z96 Class 1 Level FR
  • Portwest IAS3225 Arc Flash Pants & Bibs, Avenger 9oz Insulated Bib Pants — Portwest · Arc rating: 61 cal/cm2 · Material: 88% FR Cotton, 12% Nylon; Lining: Westex: 88% FR Cotton, 12% Nylon; Filling: Westex FR Modacrylic Insulation · Fabric weight: 9 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; CGSB 155.20; CSA Z462; CSA Z96 Class 1 Level FR; ASTM F1959 ATPV 61 cal/cm2
  • Portwest IUS225 Arc Flash Pants & Bibs, Ultrasoft 9oz Insulated Bib Pant — Portwest · Arc rating: 61 cal/cm2 · Material: Westex: 88% FR Cotton, 12% Nylon; Filling: Westex FR Modacrylic Insulation · Fabric weight: 9 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; CGSB 155.20; CSA Z462; CSA Z96 Class 1 Level FR; ASTM F1959 ATPV 61 cal/cm2
  • Portwest IUS525 Arc Flash Pants & Bibs, Ultrasoft 9oz Hi-Vis Insulated Bib Pant — Portwest · Arc rating: 61 cal/cm2 · Material: Westex: 88% FR Cotton, 12% Nylon; Filling: Westex: 88% FR Cotton, 12% Nylon · Fabric weight: 9 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; CGSB 155.20; CSA Z462; CSA Z96 Class 2 Level 2; ASTM F1959 ATPV 61 cal/cm2
Arc Flash Kits3 garments
Coveralls & Overalls3 garments
Arc-Rated Harnesses1 garment

Do not see what you need? Browse the category or call (925) 215-7337.

In plain words. An arc rating is the amount of heat energy, in calories per square centimetre, that a fabric blocked before the test predicted a second-degree burn; it is printed on the garment label as ATPV or EBT. NFPA 70E groups PPE into categories by the minimum rating: Category 1 needs 4 cal/cm², Category 2 8, Category 3 25, Category 4 40. Flame resistance (the fabric self-extinguishes) is a separate test from the arc rating; a garment can be FR without an arc rating. Every number here is the manufacturer's.

Technical. Arc ratings by ASTM F1959 (reported as ATPV, or EBT where the fabric breaks open first); FR garment performance by ASTM F1506 (electric arc) and NFPA 2112 (flash fire, with NFPA 2113 for selection); NFPA 70E Table 130.7(C)(15)(c) sets the PPE categories by incident energy. Hi-vis FR garments also carry an ANSI/ISEA 107 class. Fabric weights are in ounces per square yard as published.

Ratings and specifications on this page are shown as published by the manufacturer or the named standard and describe performance in that standard's test. They are not a recommendation for any task. The employer's hazard assessment decides what protective equipment a job needs. Verify details against the manufacturer's current documentation before you buy.

The standard at a glance

Copied from the named standard or regulation and shown with its source; nothing in these tables is Bayshore's recommendation.

NFPA 70E PPE categories
PPE categoryMinimum arc rating of the clothing system
Category 14 cal/cm²
Category 28 cal/cm²
Category 325 cal/cm²
Category 440 cal/cm²

Source: NFPA 70E, Table 130.7(C)(15)(c). Arc ratings (ATPV or EBT) tested to ASTM F1959; FR garments to ASTM F1506 and NFPA 2112.

Need help choosing?Call us with the job and the hazard; we will point you at the products the manufacturers rate for it.
Call (925) 215-7337
How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.