12 DuPont Tychem 2000 items we carry (apron, coverall, sleeve). Manufacturer test data, chemical and barrier results and the standards named on the data sheet.
What DuPont Tychem 2000 is
DuPont Tychem 2000 is The garment shall be constructed of DuPont™ Tychem® 2000 -- a DuPont™ Tyvek® protective fabric coated with 1.25 mils of polyethylene.; Tychem® 2000 is yellow for high visibility. The manufacturer names these applications: Used extensively in the petroleum; pulp and paper; food and chemical processing; and pharmaceutical industries. Seams: Seam types on the SafeSPEC pages for this family: Bound, Serged, Taped; Serged or sewn*: A seam produced when three threads are interlocked around the raw edges of two pieces of material for a strong, stress-resistant seam. For potential misting exposure of non-hazardous liquids or particle penetrat. Shelf life per the manufacturer: What is the shelf life of Tychem® 2000 garments? Tychem® garments may be used for 5 years from the date of manufacture as long as all of the following conditions are met: The garment has been stored p.
In the manufacturer's words: "A lightweight, and durable fabric, Tychem® 2000 fabric provides at least 30 minutes of protection against >40 chemical challenges. Tychem® 2000 is used for light splash protection in a variety of industrial environments, including petroleum refining, pulp and paper manufacturing, food processing, chemical processing, and pharmaceutical manufacturing."
Every DuPont Tychem 2000 item we carry
Prices refresh from the store at the unit shown on the product page. Sized garments open the product page to pick the size.
DuPont Tychem 2000 physical properties (manufacturer test data)
| Test | Method | Result |
|---|---|---|
| Thickness | ASTM D1777 | 10 mils |
| Basis Weight | ASTM D3776 | 2.5 oz/yd^2 |
| Burst Strength - Mullen | ASTM D3786 | 68 psi |
| Tear Resistance - Trap Tear (MD) | ASTM D5587 | 6.4 lbf |
| Tear Resistance - Trap Tear (CD) | ASTM D5587 | 5 lbf |
| Breaking Strength - Grab (MD) | ASTM D5034 | 39 lbf |
| Breaking Strength - Grab (CD) | ASTM D5034 | 43 lbf |
| Wearing Apparel Flammability | 16 CFR 1610 | Class 1 |
Source: DuPont published data (dupont-tychem-2000-qc127s-yl.html), copied as published. The employer's hazard assessment under OSHA 29 CFR 1910.132 decides what a job needs; these are the manufacturer's test results, not a fitness statement for any task.
DuPont Tychem 2000: SafeSPEC CHEMICAL RESISTANCE table for Tychem 2000 (as shown on the QC127S product page)
| Hazard / Chemical Name | Cas Number | Phase | Normalized Break Through |
|---|---|---|---|
| 2-Methyl-4-isothiazolin-3-one (20%) | 2682-20-4 | Liquid | >480 |
| Acetic acid (>95%) | 64-19-7 | Liquid | imm |
| Acetic acid ethyl ester | 141-78-6 | Liquid | imm |
| Acetone | 67-64-1 | Liquid | imm |
| Acetonitrile | 75-05-8 | Liquid | imm |
| Acroleic acid | 79-10-7 | Liquid | imm |
| Acrylic acid | 79-10-7 | Liquid | imm |
| Acrylonitrile | 107-13-1 | Liquid | imm |
| Amido sulfonic acid (15%) | 5329-14-6 | Liquid | >480 |
| Amino benzene | 62-53-3 | Liquid | imm |
| Ammonia (gaseous) | 7664-41-7 | Vapor | imm |
| Ammonium hydroxide (28% - 30%) | 1336-21-6 | Liquid | imm |
| Aniline | 62-53-3 | Liquid | imm |
| Benzenamine | 62-53-3 | Liquid | imm |
| Benzisothiazol 1,2- (20%) | 2634-33-5 | Liquid | >480 |
| Black Liquor (mix) | mix | Liquid | >480 |
| Bromine | 7726-95-6 | Liquid | imm |
| Butadiene, 1,3- (gaseous) | 106-99-0 | Vapor | imm |
| Butanal, n- | 123-72-8 | Liquid | imm |
| Butanol, 1- | 71-36-3 | Liquid | imm |
| Butanol, n- | 71-36-3 | Liquid | imm |
| Butyl alcohol, n- | 71-36-3 | Liquid | imm |
| Butyraldehyde, n- | 123-72-8 | Liquid | imm |
| Carbon disulfide | 75-15-0 | Liquid | imm |
| Carmustine (3.3 mg/ml, 10 % Ethanol) | 154-93-8 | Liquid | >240 |
| Caustic ammonia (28% - 30%) | 1336-21-6 | Liquid | imm |
| Caustic soda (50%) | 1310-73-2 | Liquid | >480 |
| Chemguard S-764P14A | mix | Liquid | >480 |
| Chlorine (20 ppm) | 7782-50-5 | Vapor | >480^8 |
| Chlorine (gaseous) | 7782-50-5 | Vapor | imm |
| Chloro 2-nitrobenzene, 1- | 88-73-3 | Solid | 15 |
| Chloro acetic acid (80%) | 79-11-8 | Liquid | >480 |
| Chloro ethanol, 2- | 107-07-3 | Liquid | imm |
| Chloroform | 67-66-3 | Liquid | imm |
| Cresol o- | 95-48-7 | Liquid | 13 |
| Cresols, mixed isomers | 1319-77-3 | Liquid | 71 |
| Cresylic acid | 1319-77-3 | Liquid | 71 |
| Cyanoethylene | 107-13-1 | Liquid | imm |
| Cyanomethane | 75-05-8 | Liquid | imm |
| Cyclo phosphamide (20 mg/ml) | 50-18-0 | Liquid | >240 |
| Diaminoethane, 1,2- | 107-15-3 | Liquid | >480 |
| Dichloro methane | 75-09-2 | Liquid | imm |
| Diesel automotive test fuel | mix | Liquid | imm |
| Diethyl amine | 109-89-7 | Liquid | imm |
| Dimethyl acetamide N,N- (30%) | 127-19-5 | Liquid | >480 |
| Dimethyl acetamide N,N- (8%) | 127-19-5 | Liquid | >480 |
| Dimethyl formamide, N,N- | 68-12-2 | Liquid | imm |
| Dimethyl ketal | 67-64-1 | Liquid | imm |
| Dimethyl ketone | 67-64-1 | Liquid | imm |
| Diphenyl methane diisocyanate, 4,4'- (50 °C, molten) | 101-68-8 | Liquid | >480 |
| Disodium sulfide (60% (slurry)) | 1313-82-2 | Liquid | >480 |
| Doxorubicin HCl (2 mg/ml) | 25136-40-9 | Liquid | >240 |
| DuPont Activator 193S (mix) | mix | Liquid | >480 |
| DuPont Activator 4505S (mix) | mix | Liquid | >480 |
| DuPont Activator 4507S (mix) | mix | Liquid | >480 |
| Epoxy ethane (gaseous) | 75-21-8 | Vapor | imm |
| Ethane 1,2-diol | 107-21-1 | Liquid | >480 |
| Ethane nitrile | 75-05-8 | Liquid | imm |
| Ethyl acetate | 141-78-6 | Liquid | imm |
| Ethyl ethanamine, N- | 109-89-7 | Liquid | imm |
| Ethyl nitrile | 75-05-8 | Liquid | imm |
| Ethylene carboxylic acid | 79-10-7 | Liquid | imm |
| Ethylene chlorohydrin | 107-07-3 | Liquid | imm |
| Ethylene diamine | 107-15-3 | Liquid | >480 |
| Ethylene glycol | 107-21-1 | Liquid | >480 |
| Ethylene oxide (gaseous) | 75-21-8 | Vapor | imm |
| Ethylene tetrachloride | 127-18-4 | Liquid | imm |
| Etoposide (Toposar®, Teva) (20 mg/ml, 33.2 % (v/v) Ethanol) | 33419-42-0 | Liquid | >240 |
| Fluorouracil, 5- (50 mg/ml) | 51-21-8 | Liquid | >240 |
| Formalin (3.7%, 1-1.5% Methanol) | 50-00-0 | Liquid | >480 |
| Formalin (37% (10-15% Methanol)) | 50-00-0 | Liquid | imm |
| Fuel-oil no 2 | 68476-30-2 | Liquid | imm |
| Glutaral (5%) | 111-30-8 | Liquid | >480 |
| Glutaraldehyde (5%) | 111-30-8 | Liquid | >480 |
| Glycol alcohol | 107-21-1 | Liquid | >480 |
| Glycol chlorohydrin | 107-07-3 | Liquid | imm |
| Green Liquor (mix) | mix | Liquid | >480 |
| Hexamethylene diisocyanate | 822-06-0 | Liquid | >480 |
| Hexane, n- | 110-54-3 | Liquid | imm |
| Hydrochloric acid (37%) | 7647-01-0 | Liquid | 140 |
| Hydrofluoric acid (48-51%) | 7664-39-3 | Liquid | 280 |
| Hydrogen chloride (gaseous) | 7647-01-0 | Vapor | imm |
| Hydrogen fluoride (20-27 °C, gaseous) | 7664-39-3 | Vapor | imm |
| Hydrogen peroxide (30%) | 7722-84-1 | Liquid | >480 |
| Hydrogen peroxide (50%) | 7722-84-1 | Liquid | >480 |
| Hydrogen peroxide (70%) | 7722-84-1 | Liquid | >480 |
| Hydroxy toluene, o- | 95-48-7 | Liquid | 13 |
| Isopropanol | 67-63-0 | Liquid | imm |
| Isopropanol (70%) | 67-63-0 | Liquid | imm |
| Isopropyl alcohol | 67-63-0 | Liquid | imm |
| Isopropyl alcohol (70%) | 67-63-0 | Liquid | imm |
| Ketone propane | 67-64-1 | Liquid | imm |
| Limonene d- | 5989-27-5 | Liquid | imm |
| Lithium chloride (20%) | 7447-41-8 | Liquid | >480 |
| Lithium hydroxide (14.9%) | 1310-65-2 | Liquid | >480 |
| Mercury | 7439-97-6 | Liquid | >480 |
| Methanol | 67-56-1 | Liquid | imm |
| Methyl 2-pyrrolidone, N- | 872-50-4 | Liquid | imm. |
| Methyl 4-isopropenyl-1-cyclohexene, 1- | 5989-27-5 | Liquid | imm |
| Methyl acetyl | 67-64-1 | Liquid | imm |
| Methyl benzol | 108-88-3 | Liquid | imm |
| Methyl chloride (gaseous) | 74-87-3 | Vapor | imm |
| Methyl cyanide | 75-05-8 | Liquid | imm |
| Methyl ketone | 67-64-1 | Liquid | imm |
| Methyl phenols | 1319-77-3 | Liquid | 71 |
| Methyl salicylate | 119-36-8 | Liquid | <15 |
| Methylene chloride | 75-09-2 | Liquid | imm |
| Methylene diphenyl diisocyanate, 4,4'- (50 °C, molten) | 101-68-8 | Liquid | >480 |
| Mineral spirit | 64475-85-0 | Liquid | imm |
| Nitric acid (70%) | 7697-37-2 | Liquid | 213 |
| Nitro benzene | 98-95-3 | Liquid | imm |
| Nitro chlorobenzene, p- | 100-00-5 | Solid | imm |
| Nitro toluene, p- | 99-99-0 | Solid | imm |
| Oleum (103% (13% free SO3)) | 8014-95-7 | Liquid | 230 |
| Oleum (20% free SO3) | 8014-95-7 | Liquid | 60 |
| Paclitaxel (Hospira) (6 mg/ml, 49.7 % (v/v) Ethanol) | 33069-62-4 | Liquid | >240 |
| Pentanedial, 1,5- (5%) | 111-30-8 | Liquid | >480 |
| Phenol (85%) | 108-95-2 | Liquid | 11 |
| Phenyl amine | 62-53-3 | Liquid | imm |
| Phosphoric acid (85%) | 7664-38-2 | Liquid | >480 |
| Polymethylene polyphenyle isocyanate (p-MDI) | 9016-87-9 | Liquid | >480 |
| Potassium cyanide (10%) | 151-50-8 | Liquid | >480 |
| Potassium hydroxide (45%) | 1310-58-3 | Liquid | >480 |
| Potassium permanganate (sat) | 7722-64-7 | Liquid | >480 |
| Propan -2-ol | 67-63-0 | Liquid | imm |
| Propan -2-ol (70%) | 67-63-0 | Liquid | imm |
| Propan -2-one | 67-64-1 | Liquid | imm |
| Propene acid | 79-10-7 | Liquid | imm |
| Propenenitrile, 2- | 107-13-1 | Liquid | imm |
| Propenoic acid nitrile | 107-13-1 | Liquid | imm |
| Pyroacetic ether | 67-64-1 | Liquid | imm |
| Sodium cyanide (45%) | 143-33-9 | Liquid | >480 |
| Sodium hydroxide (50%) | 1310-73-2 | Liquid | >480 |
| Sodium hypochlorite (15%) | 7681-52-9 | Liquid | >480 |
| Sodium hypochlorite (5.25-6%) | 7681-52-9 | Liquid | >480 |
| Sodium metabisulphite (38%) | 7681-57-4 | Liquid | imm |
| Sodium silicate (40-42%) | 6834-92-0 | Liquid | >480 |
| Spectracide® (50% Malathion, 44% Aromatic Solvent) | mix | Liquid | imm |
| Sulfamic acid (15%) | 5329-14-6 | Liquid | >480 |
| Sulfamidic acid (15%) | 5329-14-6 | Liquid | >480 |
| Sulfur dioxide | 7446-09-5 | Vapor | imm |
| Sulfuric acid (>95%) | 7664-93-9 | Liquid | >480 |
| Sulfuric acid fuming (103% (13% free SO3)) | 8014-95-7 | Liquid | 230 |
| Sulfuric acid fuming (20% free SO3) | 8014-95-7 | Liquid | 60 |
| Tetrachloro ethylene, 1,1,2,2- | 127-18-4 | Liquid | imm |
| Tetrahydrofuran | 109-99-9 | Liquid | imm |
| Tetramethyl ammonium hydroxide (25%) | 75-59-2 | Liquid | >480 |
| Thiotepa (10 mg/ml) | 52-24-4 | Liquid | >240 |
| Toluene | 108-88-3 | Liquid | imm |
| Toluene diisocyanate, 2,4- | 584-84-9 | Liquid | imm |
| Toluene diisocyanate, 2,4- (80%) | 584-84-9 | Liquid | 60 |
| Trichloro benzene, 1,2,4- | 120-82-1 | Liquid | imm |
| Trichloro methane | 67-66-3 | Liquid | imm |
| Trifluoro ethanol, 2,2,2- | 75-89-8 | Liquid | imm |
| Vinyl cyanide | 107-13-1 | Liquid | imm |
| Vinyl ethylene (gaseous) | 106-99-0 | Vapor | imm |
| White Liquor | mix | Liquid | >480 |
Source: DuPont published data (dupont-tychem-2000-qc127s-yl.html), copied as published. The employer's hazard assessment under OSHA 29 CFR 1910.132 decides what a job needs; these are the manufacturer's test results, not a fitness statement for any task.
DuPont Tychem 2000: 21 Industrial chemicals ASTM F1001 — Permeation data (catalog p.10), column for Tychem® 2000*
Index of codes: > = greater than, imm. = immediate (<10 minutes), nt = not tested, L = liquid, G = gas. Normalized Breakthrough Time (NBT) shown in minutes. *Serged and/or bound seams are degraded by some hazardous liquid chemicals, such as strong acids, and should not be worn when these chemicals are present. Permeation testing on chemicals is in accordance with ASTM F739, Standard Test Method for Resistance of Protective Clothing Materials to Permeation by Liquids or Gases Under Conditions of Continuous Contact. All tests are conducted at room temperature unless otherwise noted. Reported results are Normalized Breakthrough Times defined by ASTM F739 as the time (in minutes) when the permeation rate reaches 0.1 µg/cm2/min. Note: Numbers reported are averages of samples tested. Sample results vary. All DuPont permeation testing is performed by a third party. Transcribed from the reading-order text of catalog p.10; the chemical-warfare-agent rows were not transcribed (superscript footnote markers are fused to the numbers in the text layer).
| Chemical | CAS # | Physical phase | NBT (minutes) Tychem® 2000* |
|---|---|---|---|
| Acetone (95%) | 67-64-1 | L | imm. |
| Acetonitrile (95%) | 75-05-8 | L | imm. |
| Ammonia (95%) | 7664-41-7 | G | imm. |
| 1, 3-Butadiene (95%) | 106-99-0 | G | imm. |
| Carbon disulfide (95%) | 75-15-0 | L | imm. |
| Chlorine (95%) | 7782-50-5 | G | imm. |
| Dichloromethane (95%) | 75-09-2 | L | imm. |
| Diethylamine (95%) | 109-89-7 | L | imm. |
| N, N-Dimethylformamide (95%) | 68-12-2 | L | imm. |
| Ethyl acetate (95%) | 141-78-6 | L | imm. |
| Ethylene oxide (95%) | 75-21-8 | G | imm. |
| n-Hexane (95%) | 110-54-3 | L | imm. |
| Hydrogen chloride (95%) | 7647-01-0 | G | imm. |
| Methanol (95%) | 67-56-1 | L | imm. |
| Methyl chloride (95%) | 74-87-3 | G | imm. |
| Nitrobenzene (95%) | 98-95-3 | L | imm. |
| Sodium hydroxide (50%) | 1310-73-2 | L | >480 |
| Sulfuric acid (95%) | 7664-93-9 | L | >480 |
| 1, 1, 2, 2-Tetrachloroethylene (95%) | 127-18-4 | L | imm. |
| Tetrahydrofuran (95%) | 109-99-9 | L | imm. |
| Toluene (95%) | 108-88-3 | L | imm. |
Source: DuPont published data (DPP_CI_Catalog_2024_V2.pdf), copied as published. The employer's hazard assessment under OSHA 29 CFR 1910.132 decides what a job needs; these are the manufacturer's test results, not a fitness statement for any task.
DuPont Tychem 2000 barrier tests
| Test | Method | Result |
|---|---|---|
| Passes ASTM F1670 and ASTM F1671 tests, offering bloodborne pathogen protection | ASTM F1670 / ASTM F1671 | (statement) |
Source: DuPont published data (DPP_CI_Catalog_2024_V2.pdf), copied as published. The employer's hazard assessment under OSHA 29 CFR 1910.132 decides what a job needs; these are the manufacturer's test results, not a fitness statement for any task.
Standards named by the manufacturer for DuPont Tychem 2000
| Standard | What the manufacturer states |
|---|---|
| 16 CFR 1610 | Wearing Apparel Flammability: Class 1 |
Source: DuPont published data (dupont-tychem-2000-qc127s-yl.html), copied as published. The employer's hazard assessment under OSHA 29 CFR 1910.132 decides what a job needs; these are the manufacturer's test results, not a fitness statement for any task.
Manufacturer limitations and warnings
- Warning: Most Tychem® garments should not be used around heat, flames, sparks or in potentially flammable or explosive environments.
- These Tychem® 2000 garments have attached socks made of the garment material. These attached socks must be worn inside protective outer footwear and are not suitable as outer footwear. These attached socks do not have adequate durability or slip resistance to be worn as the outer foot covering.
- Please note that Tychem® fabrics have different permeation performance. Please check DuPont™ SafeSPEC™ for permeation data that meets your specific needs.
- Storm flaps: All standard bound and taped seam coveralls have a single storm flap with a pressure-sensitive tape closure. Serged seam coveralls do not have a storm flap. (catalog p.20)
- *Serged and bound seams are degraded by some hazardous liquid chemicals, such as strong acids, and should not be worn when these chemicals are present.
- *CAUTION: This information is based upon technical data that DuPont believes to be reliable. It is subject to revision as additional knowledge and experience are gained. DuPont makes no guarantee of results and assumes no obligation or liability in connection with this information. It is the user's responsibility to determine the level of toxicity and the proper personal protective equipment needed. The information set forth herein reflects laboratory performance of fabrics, not complete garments, under controlled conditions. It is intended for informational use by persons having technical skill for evaluation under their specific end-use conditions, at their own discretion and risk. Anyone intending to use this information should first verify that the garment selected is suitable for the intended use. In many cases, seams and closures have shorter breakthrough times and higher permeation rates than the fabric. Please contact DuPont for specific data. If fabric becomes torn, abraded or punctured, or if seams or closures fail, or if attached gloves, visors, etc. are damaged, end user should discontinue use of garment to avoid potential exposure to chemical. Since conditions of use are outside our control, we make no warranties, express or implied, including, without limitation, no warranties of merchantability or fitness for a particular use and assume no liability in connection with any use of this information. This information is not intended as a license to operate under or a recommendation to infringe any patent or technical information of DuPont or others covering any material or its use. Cellosolve® and Selexol™ are registered trademarks of Dow Chemicals Company. Skydrol® is a registered trademark of Solutia.
- As of January 2023, all DuPont Personal Protection products are manufactured under specifications that exclude components containing natural rubber latex. Tyvek® 500, Tyvek® 600 and Tyvek® 800 styles made before January 2023 contain natural rubber latex, which may cause allergic reactions in some sensitized individuals. Anyone who begins to exhibit an allergic response during the use of DuPont products should immediately cease using these products and should report it to DuPont at +1 (888) 439-2988 so that an investigation can be initiated.
- Please read, understand and follow the Tychem® User Manual.
- Wear other appropriate PPE such as, but not limited to, respiratory, eye, head, hand, and foot protection based on the hazard assessment.
DuPont Tychem 2000 questions
What is DuPont Tychem 2000 made of? The garment shall be constructed of DuPont™ Tychem® 2000 -- a DuPont™ Tyvek® protective fabric coated with 1.25 mils of polyethylene.; Tychem® 2000 is yellow for high visibility
Which DuPont Tychem 2000 garments does Bayshore Safety carry? QC273B (DuPont Tychem D13396835 Chemical Resistant Clothing, Bib Apron, 10 mil), QC127S (DuPont Tychem Chemical Resistant Clothing, Coverall, Hood), QC127S (DuPont Tychem D15544198 Chemical Resistant Clothing, Hi-Vis Hooded Coverall), QC500B (DuPont Tychem D13396840 Sleeves & Bibs, Chemical Splash Sleeve, 18 in), QC500B (DuPont Tychem QC500B-00 Sleeves & Bibs, in L), QC120S (DuPont Tychem Chemical Resistant Clothing, Coverall, Collar), QC122S (DuPont Tychem QC122SYL Chemical Resistant Clothing, Hooded Coverall, Yellow), QC125S (DuPont Tychem D13480109 Chemical Resistant Clothing, Coverall, Collar), QC120S, QC122S, QC125S, QC127S, QC127B (DuPont Tychem Coveralls), QC125S (DuPont Tychem Coveralls, Serged Seams, Collar), and 2 more.
What standards does the manufacturer name for DuPont Tychem 2000? 16 CFR 1610. The wording for each is in the standards table above.
Does the manufacturer publish chemical test data for DuPont Tychem 2000? Yes: 2 tables on this page (SafeSPEC CHEMICAL RESISTANCE table for Tychem 2000 (as shown on the QC127S product page); 21 Industrial chemicals ASTM F1001 — Permeation data (catalog p.10), column for Tychem® 2000*), copied from the manufacturer. Penetration and permeation are different tests; the guide on permeation versus penetration explains how to read them.
What does the manufacturer warn about DuPont Tychem 2000? Warning: Most Tychem® garments should not be used around heat, flames, sparks or in potentially flammable or explosive environments. These Tychem® 2000 garments have attached socks made of the garment material. These attached socks must be worn inside protective outer footwear and are not suitable as outer footwear. These attached socks do not have adequate durability or slip resistance to be worn
Is this a statement that the garment is compliant for my job? No. These are the manufacturer's published test results and the standards it names. Under OSHA 29 CFR 1910.132 the employer's hazard assessment decides which protective clothing a task needs.
See also: the disposable coverall fabrics hub, the disposable garment selector and the disposable coverall guides.