DuPont Tyvek 800 Disposable Protective Clothing
1 DuPont Tyvek 800 item we carry (coverall). Manufacturer test data, chemical and barrier results and the standards named on the data sheet.
What DuPont Tyvek 800 is
DuPont Tyvek 800 is The garment shall be constructed of DuPont™ Tyvek® 800.; Tyvek® 800 is white. The manufacturer names these applications: Suitable for applications such as industrial cleaning; chemical packaging and redistribution; waste treatment and disposal; environmental remediation and many others. Seams: Seam types on the SafeSPEC pages for this family: Taped; Serged or sewn*: A seam produced when three threads are interlocked around the raw edges of two pieces of material for a strong, stress-resistant seam. For potential misting exposure of non-hazardous liquids or particle penetration through the. Shelf life per the manufacturer: What is the shelf life of Tyvek® 800 garments? DuPont suggests that Tyvek® garments be used within 5 years of receipt, provided they are properly stored and pass a full visual inspection. High tempera.
In the manufacturer's words: "Tyvek® 800 garments combine resistance to low-concentration, water-based, inorganic chemicals (even under pressure) with the strength and durability of Tyvek® thanks to an innovative fabric technology and enhanced garment design. Developed to our highest standards, Tyvek® 800 coveralls are soft, comfortable and lightweight without compromising their level of durability. They are now available with serged and over-taped seams that provide the performance of Type 3/4/5/6 garments, which have "
Every DuPont Tyvek 800 item we carry
| Part number | Item | Seams | Sizes | Case | Price | ||
|---|---|---|---|---|---|---|---|
![]() | TJ198T | DuPont Tyvek D154416 800 Taped Seam Coverall, Hood | Taped | L, XL, 2XL | 25 per case | $16.15 | Choose size |
Prices refresh from the store at the unit shown on the product page. Sized garments open the product page to pick the size.
DuPont Tyvek 800 physical properties (manufacturer test data)
| Test | Method | Result |
|---|---|---|
| Basis Weight | DIN EN ISO 536 | 59 g/m2 |
| Puncture Resistance | EN 863 | 15 N |
| Tear Resistance - Trap Tear (MD) | EN ISO 9073-4 | 31 N |
| Tear Resistance - Trap Tear (CD) | EN ISO 9073-4 | 32 N |
| Tensile Strength (MD) | DIN EN ISO 13934-1 | 93 N |
| Tensile Strength (XD) | DIN EN ISO 13934-1 | 72 N |
| Resistance to water penetration | DIN EN 20811 | >25 kPa (>100 inches H2O) |
| Surface Resistivity (23°C / 25% RH) | EN 1149-1 | <2.5 x 10^9 ohms |
| Wearing Apparel Flammability | 16 CFR 1610 | Class 1 |
Source: DuPont published data (dupont-tyvek-800-tj198t-wh.html), copied as published. The employer's hazard assessment under OSHA 29 CFR 1910.132 decides what a job needs; these are the manufacturer's test results, not a fitness statement for any task.
DuPont Tyvek 800: SafeSPEC CHEMICAL RESISTANCE table for Tyvek 800 (as shown on the TJ198T product page)
| Hazard / Chemical Name | Cas Number | Phase | Normalized Break Through |
|---|---|---|---|
| Acetic acid (10%) | 64-19-7 | Liquid | imm |
| Acetic acid (2%) | 64-19-7 | Liquid | imm |
| Acetic acid (30%) | 64-19-7 | Liquid | imm |
| Acetic acid (5%) | 64-19-7 | Liquid | imm |
| Ammonium hydroxide (16%) | 1336-21-6 | Liquid | imm |
| Carboplatin (10 mg/ml) | 41575-94-4 | Liquid | >240 |
| Carmustine (3.3 mg/ml, 10 % Ethanol) | 154-93-8 | Liquid | >240 |
| Caustic ammonia (16%) | 1336-21-6 | Liquid | imm |
| Caustic soda (10%) | 1310-73-2 | Liquid | >480 |
| Caustic soda (50%) | 1310-73-2 | Liquid | >480 |
| Cisplatin (1 mg/ml) | 15663-27-1 | Liquid | >240 |
| Cyclo phosphamide (20 mg/ml) | 50-18-0 | Liquid | >240 |
| Doxorubicin HCl (2 mg/ml) | 25136-40-9 | Liquid | >240 |
| Ethane 1,2-diol | 107-21-1 | Liquid | imm |
| Ethanol | 64-17-5 | Liquid | imm |
| Ethyl alcohol | 64-17-5 | Liquid | imm |
| Ethylene glycol | 107-21-1 | Liquid | imm |
| Etoposide (Toposar®, Teva) (20 mg/ml, 33.2 % (v/v) Ethanol) | 33419-42-0 | Liquid | >240 |
| Fluorouracil, 5- (50 mg/ml) | 51-21-8 | Liquid | >240 |
| Formaldehyde (10%) | 50-00-0 | Liquid | imm |
| Formalin (10%) | 50-00-0 | Liquid | imm |
| Gemcitabine (38 mg/ml) | 95058-81-4 | Liquid | >240 |
| Glycol alcohol | 107-21-1 | Liquid | imm |
| Hydrochloric acid (16%) | 7647-01-0 | Liquid | imm |
| Hydrochloric acid (32%) | 7647-01-0 | Liquid | imm |
| Hydrofluoric acid (10%) | 7664-39-3 | Liquid | imm |
| Ifosfamide (50 mg/ml) | 3778-73-2 | Liquid | >240 |
| Isopropanol | 67-63-0 | Liquid | imm |
| Isopropanol (70%) | 67-63-0 | Liquid | imm |
| Isopropyl alcohol | 67-63-0 | Liquid | imm |
| Isopropyl alcohol (70%) | 67-63-0 | Liquid | imm |
| Methotrexate (25 mg/ml, 0.1 N NaOH) | 59-05-2 | Liquid | >240 |
| Mitomycin (0.5 mg/ml) | 50-07-7 | Liquid | >240 |
| Nitric acid (30%) | 7697-37-2 | Liquid | imm |
| Oxaliplatin (5 mg/ml) | 63121-00-6 | Liquid | >240 |
| Paclitaxel (Hospira) (6 mg/ml, 49.7 % (v/v) Ethanol) | 33069-62-4 | Liquid | >240 |
| Phosphoric acid (50%) | 7664-38-2 | Liquid | >480 |
| Potassium hydroxide (40%) | 1310-58-3 | Liquid | >120 |
| Propan -2-ol | 67-63-0 | Liquid | imm |
| Propan -2-ol (70%) | 67-63-0 | Liquid | imm |
| Sodium hydroxide (10%) | 1310-73-2 | Liquid | >480 |
| Sodium hydroxide (50%) | 1310-73-2 | Liquid | >480 |
| Sodium hypochlorite (10-15 % active chlorine) | 7681-52-9 | Liquid | >480 |
| Sodium hypochlorite (5.25-6%) | 7681-52-9 | Liquid | >480 |
| Spiritus | 64-17-5 | Liquid | imm |
| Sulfuric acid (18%) | 7664-93-9 | Liquid | >480 |
| Sulfuric acid (30%) | 7664-93-9 | Liquid | >480 |
| Thiotepa (10 mg/ml) | 52-24-4 | Liquid | >240 |
Source: DuPont published data (dupont-tyvek-800-tj198t-wh.html), copied as published. The employer's hazard assessment under OSHA 29 CFR 1910.132 decides what a job needs; these are the manufacturer's test results, not a fitness statement for any task.
DuPont Tyvek 800 barrier tests
| Test | Method | Result |
|---|---|---|
| Resistance to water penetration | DIN EN 20811 | >25 kPa (>100 inches H2O) |
| Chemical protective clothing, Category III, Type 3-B, 4-B, 5-B and 6-B. | (statement) | (statement) |
| Meets the U.S. industry requirements for blood (ASTM F1670) and viral penetration (ASTM F1671) protecting against several bloodborne pathogen exposure risks. | (statement) | (statement) |
| Protection against infective agents (EN 14126) including resistance to penetration by blood and body fluids using synthetic blood (ISO 16603) and resistance to penetration by blood-borne pathogens using Phi-X174 bacteriophage (ISO 16604) | (statement) | (statement) |
| EN 1073-2 (protection against radioactive contamination) | (statement) | (statement) |
Source: DuPont published data (dupont-tyvek-800-tj198t-wh.html), copied as published. The employer's hazard assessment under OSHA 29 CFR 1910.132 decides what a job needs; these are the manufacturer's test results, not a fitness statement for any task.
Standards named by the manufacturer for DuPont Tyvek 800
| Standard | What the manufacturer states |
|---|---|
| Category III, Type 3-B, 4-B, 5-B and 6-B | Chemical protective clothing, Category III, Type 3-B, 4-B, 5-B and 6-B |
| EN 14126 | Protection against infective agents (EN 14126), including resistance to penetration by blood and body fluids using synthetic blood (ISO 16603) |
| EN 1149-1 | Surface Resistivity (23°C / 25% RH): <2.5 x 10^9 ohms |
| 16 CFR 1610 | Wearing Apparel Flammability: Class 1 |
Source: DuPont published data (DPP_CI_Catalog_2024_V2.pdf, dupont-tyvek-800-tj198t-wh.html), copied as published. The employer's hazard assessment under OSHA 29 CFR 1910.132 decides what a job needs; these are the manufacturer's test results, not a fitness statement for any task.
Manufacturer limitations and warnings
- *Serged and bound seams are degraded by some hazardous liquid chemicals, such as strong acids, and should not be worn when these chemicals are present.
- Tyvek® 800 products manufactured before January 2023 did contain natural rubber latex which may cause allergic reactions in some sensitized individuals. Anyone who begins to exhibit an allergic response during the use of DuPont products should immediately cease using these products. The incident should also be reported to DuPont at +1 (888) 439-2988 so that an investigation can be initiated.
- **Garments made using Tyvek® 400, Tyvek® 500, Tyvek® 600 and Tyvek® 800 fabrics will burn and possibly melt. None of these garments should be worn near heat, open flames, sparks or any other possible ignition source nor should they be worn in potentially explosive or flammable environments. If these garments do burn or melt while being worn, it may increase the severity of burn injuries even when worn over garments which are flame resistant, including, but not limited to, Nomex® IIIA or Nomex® Comfort garments.
- *CAUTION: This information is based upon technical data that DuPont believes to be reliable. It is subject to revision as additional knowledge and experience are gained. DuPont makes no guarantee of results and assumes no obligation or liability in connection with this information. It is the user's responsibility to determine the level of toxicity and the proper personal protective equipment needed. The information set forth herein reflects laboratory performance of fabrics, not complete garments, under controlled conditions. It is intended for informational use by persons having technical skill for evaluation under their specific end-use conditions, at their own discretion and risk. Anyone intending to use this information should first verify that the garment selected is suitable for the intended use. In many cases, seams and closures have shorter breakthrough times and higher permeation rates than the fabric. Please contact DuPont for specific data. If fabric becomes torn, abraded or punctured, or if seams or closures fail, or if attached gloves, visors, etc. are damaged, end user should discontinue use of garment to avoid potential exposure to chemical. Since conditions of use are outside our control, we make no warranties, express or implied, including, without limitation, no warranties of merchantability or fitness for a particular use and assume no liability in connection with any use of this information. This information is not intended as a license to operate under or a recommendation to infringe any patent or technical information of DuPont or others covering any material or its use. Cellosolve® and Selexol™ are registered trademarks of Dow Chemicals Company. Skydrol® is a registered trademark of Solutia.
- As of January 2023, all DuPont Personal Protection products are manufactured under specifications that exclude components containing natural rubber latex. Tyvek® 500, Tyvek® 600 and Tyvek® 800 styles made before January 2023 contain natural rubber latex, which may cause allergic reactions in some sensitized individuals. Anyone who begins to exhibit an allergic response during the use of DuPont products should immediately cease using these products and should report it to DuPont at +1 (888) 439-2988 so that an investigation can be initiated.
- Wear other appropriate PPE such as, but not limited to, respiratory, eye, head, hand, and foot protection based on the hazard assessment.
DuPont Tyvek 800 questions
What is DuPont Tyvek 800 made of? The garment shall be constructed of DuPont™ Tyvek® 800.; Tyvek® 800 is white
Which DuPont Tyvek 800 garments does Bayshore Safety carry? TJ198T (DuPont Tyvek D154416 800 Taped Seam Coverall, Hood).
What standards does the manufacturer name for DuPont Tyvek 800? Category III, Type 3-B, 4-B, 5-B and 6-B; EN 14126; EN 1149-1; 16 CFR 1610. The wording for each is in the standards table above.
Does the manufacturer publish chemical test data for DuPont Tyvek 800? Yes: 1 table on this page (SafeSPEC CHEMICAL RESISTANCE table for Tyvek 800 (as shown on the TJ198T product page)), copied from the manufacturer. Penetration and permeation are different tests; the guide on permeation versus penetration explains how to read them.
What does the manufacturer warn about DuPont Tyvek 800? *Serged and bound seams are degraded by some hazardous liquid chemicals, such as strong acids, and should not be worn when these chemicals are present. Tyvek® 800 products manufactured before January 2023 did contain natural rubber latex which may cause allergic reactions in some sensitized individuals. Anyone who begins to exhibit an allergic response during the use of DuPont products should imme
Is this a statement that the garment is compliant for my job? No. These are the manufacturer's published test results and the standards it names. Under OSHA 29 CFR 1910.132 the employer's hazard assessment decides which protective clothing a task needs.
See also: the disposable coverall fabrics hub, the disposable garment selector and the disposable coverall guides.