Skip to main content
Disposable coverall fabrics · KleenGuard A70

KleenGuard A70 Disposable Protective Clothing

1 KleenGuard A70 item we carry (coverall). Manufacturer test data, chemical and barrier results and the standards named on the data sheet.

What KleenGuard A70 is

KleenGuard A70 is Polyethylene film (1.5 mil) and spunbond polypropylene fabric; PRODUCT MATERIAL Polyethylene/ non-woven polypropylene laminate; WEIGHT 75gsm; SEAM TYPE Bound; COLOR Yellow; COUNTRY OF ORIGIN Mexico. The manufacturer names these applications: • Hazardous waste remediation • Environmental cleanup • Petrochemical/oil refining • Tank cleaning; Primary industries: Life Sciences; Pulp & Paper; Industrial; Chemical; Machinery and Equipment. Seams: Bound Seams; Taped storm 3" zipper flap; SEAM TYPE Bound. Shelf life per the manufacturer: SHELF LIFE 5 years (Model 130 page; absent on Model 120 page). Ansell completed the acquisition of Kimberly-Clark's PPE business (KleenGuard, Kimtech, RightCycle, APEX) on July 2, 2024; K-C supported the business under a transition services agreement for about a year. ansell.com/us/en is now the manufacturer site; kcprofessional.com en-us navigation no longer lists PPE (checked 2026-11-04).

In the manufacturer's words: "KLEENGUARD* A70 Chemical Spray Protection Coveralls & Accessories. Additional Attributes: Polyethylene film (1.5 mil) and spunbond polypropylene fabric; Fabric not made with silicone; Not made with BHT preservative; Non-latex polyisoprene elastic; REFLEX* Design – see catalog for sizing chart; Taped storm 3" zipper flap; Bound Seams"

Every KleenGuard A70 item we carry

Part numberItemSeamsSizesCasePrice
09815KleenGuard 9815 A70 Chemical Splash Protection CoverallsOne size12$240.00

Prices refresh from the store at the unit shown on the product page. Sized garments open the product page to pick the size.

KleenGuard A70 physical properties (manufacturer test data)

TestMethodResult
Tensile Strength (MD)ASTM D503433.8 lbs.
Tensile Strength (CD)ASTM D503424.1 lbs.
Trapezoidal Tear (MD)INDA IST 100.212.3 lbs.
Trapezoidal Tear (CD)INDA IST 100.26.7 lbs.
Elongation (MD)N/A
Elongation (CD)N/A
Lint - # of particlesN/A
FlammabilityCPSC 1610Class 1
Static Decay (<0.5 secs.)NFPA 99Pass
Mullen BurstISO 13938-2 199927.9 psi
Air PermeabilityN/A
Moisture Vapor Transport RateN/A

Source: Kimberly-Clark Professional (KleenGuard is an Ansell brand since July 2024) published data (gotopac_a70_tds.txt), copied as published. The employer's hazard assessment under OSHA 29 CFR 1910.132 decides what a job needs; these are the manufacturer's test results, not a fitness statement for any task.

KleenGuard A70: Liquid Chemicals Resistance Test

▲Fabric passes penetration testing; however, the chemical is a known or suspected carcinogen or skin absorbed toxin. HIGH Permeation Rate: A permeation rate >400. IMMEDIATE Breakthrough: Permeation observed at or before the time of first measurement. >480 breakthrough for the entire length of the test (480 min.) Row 'Sodium Hypochlorite (17%/13%)' prints 'Pass (17%)' and '>480 (13%)'. 'Potassium Acetate (10%)*' asterisk is unexplained on the sheet.

ChemicalsLiquid Penetration ASTM F903 Test Duration 60 mins Saturation ExposureVapor Permeation ASTM F739 Normalized Breakthrough (min)Vapor Permeation ASTM F739 Rate (µg/cm2/min)
Acetone (99%)PassImmediate6.90
Acetic Acid (98%)PassNot TestedNot Tested
Acetic Anhydride (99%)PassNot TestedNot Tested
Acetonitrile▲ (99%)PassImmediate8.97
Acrylonitrile▲ (99%)PassImmediate5.46
Ammonium Hydroxide (25%)PassNot TestedNot Tested
Benzyl Alcohol▲ (60%)PassNot TestedNot Tested
Black LiquorPass>480Not Detected
Carbon Disulfide▲ (99%)PassImmediate76.3
Chlorine Gas (99%)N/AImmediate10.4
Chloroacetic Acid (80%)PassNot TestedNot Tested
Chloroacetone (95%)PassNot TestedNot Tested
Chromic Acid (60%)Pass>480Not Detected
Dichloromethane▲ (99%)PassImmediate85.1
Diesel FuelPassNot TestedNot Tested
Diethylamine▲ (99%)PassImmediate469 (High)
N,n-Dimethylformamide (99%)PassImmediate2.54
Ethyl Acetate▲ (99%)PassImmediate40.3
Ethylene Glycol (99%)Pass>480Not Detected
Ethylene Diglycol Monoethyl Ether (99%)PassNot TestedNot Tested
Formic Acid (96%)PassNot TestedNot Tested
2-Furaldehyde (99%)PassNot TestedNot Tested
GasolinePassNot TestedNot Tested
Green LiquorPass>480Not Detected
Hydrochloric Acid (37%)PassNot TestedNot Tested
Hydrofluoric Acid (48%)Pass690.19
Hydrogen Peroxide (50%)Pass>480Not Detected
Isopropyl Alcohol (99%)PassNot TestedNot Tested
KerosenePassNot TestedNot Tested
Lithium Chloride (20%)Pass>480Not Detected
Lithium Hydroxide▲ (20%)Pass>480Not Detected
Methanol▲PassImmediate1.71
Methyl Ethyl Ketone (MEK) (99%)PassNot TestedNot Tested
Mineral SpiritsPassNot TestedNot Tested
Muriatic Acid (31%)PassNot TestedNot Tested
Nitric Acid (70%)PassImmediate0.27
Nitrobenzene (99%)PassImmediate97.4
O-Nitrochlorobenzene▲ (99%)PassNot TestedNot Tested
O-Nitrotoluene (99%)PassNot TestedNot Tested
Oxalic Acid (15%)PassNot TestedNot Tested
Phenol (99%)PassNot TestedNot Tested
Phosphoric Acid (85%)PassNot TestedNot Tested
Phosphoric Trichloride (99%)PassNot TestedNot Tested
Potassium Acetate (10%)*PassNot TestedNot Tested
Potassium Chromate (10%)PassNot TestedNot Tested
Silver Nitrate (0.1 Norm)PassNot TestedNot Tested
Sodium Cyanide (10%)PassNot TestedNot Tested
Sodium Fluoride (10%)PassNot TestedNot Tested
Sodium Hydroxide (50%)Pass>480Not Detected
Sodium Hypochlorite (17%/13%)Pass (17%)>480 (13%)Not Detected
Styrene▲ (99%)PassNot TestedNot Tested
Sulfuric Acid (98%)Pass>480Not Detected
Sulfuric Acid Oleum▲ (30%)PassNot TestedNot Tested
Tetrachloroethylene▲(99%)PassImmediateHigh
Tetrahydrofuran (99%)PassImmediateHigh
Toluene▲ (99%)PassImmediateHigh
1,2,4-Trichlorobenzene (99%)PassNot TestedNot Tested
2,2,2-Trichloroethanol (99%)PassNot TestedNot Tested
2,2,2-Trifluoroethanol (99%)PassNot TestedNot Tested
White Liquor (Mixture)Pass>480Not Detected

Source: Kimberly-Clark Professional (KleenGuard is an Ansell brand since July 2024) published data (gotopac_a70_tds.txt), copied as published. The employer's hazard assessment under OSHA 29 CFR 1910.132 decides what a job needs; these are the manufacturer's test results, not a fitness statement for any task.

KleenGuard A70: Chemical Resistance Information Guide — KLEENGUARD* A70 Chemical Spray Protection (organized by ASTM F1186 class)

NT= Not Tested; Immed. = Immediate; ND = Not Detected; L = Liquid; G = Gas. Guide values differ from the 2015 TDS for Acetone (7.9 vs 6.90) and DMF (2.5 vs 2.54). Guide warning: 'This chemical passes Penetration testing but is considered a known/suspected human carcinogen or skin absorbed toxic chemical, and has a vapor pressure greater than 5 mm Hg at 77ºF (25ºC), as defined in NFPA 1992-2005 (paragraphs 4.1.11 and 4.1.12). These chemicals are considered both a liquid and vapor hazard. Suitability for use should be determined by a professional trained in industrial safety. Failure to comply with this warning can result in serious injury or death.' 'All permeation and penetration testing reported in this literature has been conducted by an independent laboratory in accordance with the American Society of Testing and Materials (ASTM) Standard Test Methods.'

Class and Sub-ClassChemical NamePhysical PhaseLiquid Penetration ASTM F903 (60 mins Saturation Exposure)Permeation ASTM F739 Normalized Breakthrough Time (minutes)Rate (µg/cm2/min)
104 Aliphatic and Alicyclic, Substituted (Acids, Carboxylic)Oxalic acid, 15%LPassNTNT
132 Aliphatic and Alicyclic (Amides)n,n-DimethylformamideLPassImmed.2.5
142 Aliphatic and Alicyclic, Secondary (Amines)DiethylamineLPassImmed.High
222 Acetates (Esters, Carboxylic)Ethyl acetateLPassImmed.40.3
241 Aliphatic and Alicyclic (Ethers)TetrahydrofuranLPassImmed.High
261/263 Aromatic (Halogen Compounds)DichloromethaneLPassImmed.85.1
264 VinylicTetrachloroethyleneLPassImmed.High
291 Aliphatic and Alicyclic, Saturated (Hydrocarbons)n-HexaneLPassImmed.High
292 AromaticTolueneLPassImmed.High
311 Aliphatic and Alicyclic, Primary (Hydroxylic Compounds)MethanolLPassImmed.1.71
314 Aliphatic and Alicyclic, PolyolsEthylene glycolLPass>480ND
300 PeroxidesHydrogen peroxide, 50%LPass>480ND
340 Inorganic Salts (Solutions)Lithium chloride, 20%LPass>480ND
340Sodium hypochlorite, 5.25%LPass>480ND
350 Inorganic Gases and VaporsChlorine gasGNot ApplicableImmed.10.4
370 Inorganic AcidsChromic acidLPass>480ND
370Sulfuric acid, 98%LPass>480ND
380 Inorganic BasesLithium hydroxide, 20%LPass>480ND
380Sodium hydroxide, 50%LPass>480ND
391 Aliphatic and Alicyclic (Ketones)AcetoneLPassImmed.7.9
441 Unsubstituted (Nitro Compounds)NitrobenzeneLPassImmed.97.4
502 Sulfides and Disulfides (Sulfur Compounds)Carbon disulfideLPassImmed.76.3
590 MiscellaneousBlack liquorLPass>480ND
590Green liquorLPass>480ND
590White liquorLPass>480ND

Source: Kimberly-Clark Professional (KleenGuard is an Ansell brand since July 2024) published data (purdue_chem_resistance_guide.txt), copied as published. The employer's hazard assessment under OSHA 29 CFR 1910.132 decides what a job needs; these are the manufacturer's test results, not a fitness statement for any task.

KleenGuard A70 barrier tests

TestMethodResult
HydroheadAATCC 127-1998300.8 cm
Particle HoldoutN/A
Blood PenetrationASTM F1670Pass
Bloodborne PathogensASTM F1671‡Pass

Source: Kimberly-Clark Professional (KleenGuard is an Ansell brand since July 2024) published data (gotopac_a70_tds.txt), copied as published. The employer's hazard assessment under OSHA 29 CFR 1910.132 decides what a job needs; these are the manufacturer's test results, not a fitness statement for any task.

Standards named by the manufacturer for KleenGuard A70

StandardWhat the manufacturer states
ASTM F1670 / ASTM F1671Blood Penetration ASTM F1670 Pass; Bloodborne Pathogens ASTM F1671‡ Pass. ‡Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Bloodborne Pathogens Using Phi-X174 Bacteriophage Penetration as a Test System.
NFPA 99Static Decay (<0.5 secs.) NFPA 99 Pass
CPSC 1610Flammability CPSC 1610 Class 1
ASTM F903 / ASTM F739see chemical_tables
EU (A70/A71 CE versions) — selector tableA71: Type 3 EN 14605:2005 Pass; Type 4 EN 14605 Pass; Type 5 EN ISO 13982-1:2004 Pass; Infective agents EN 14126:2003 Pass; Surface Resistivity EN 1149-1:1995 Pass; Radioactive dust EN 1073-2:2002 Pass; Abrasion EN 530 Method 2 class 6; Flex cracking ISO 7854 Method B 2; Trapezoidal tear ISO-9073-4 2; Tensile EN ISO 13935-2 1; Seam strength 3; Puncture EN 863 2; Resistance to ignition Pass; Resistance to permeation EN 374:3 (30% H2SO4) 6, (10% NaOH) 6; Average total inward leakage Pr ISO 13982-2 4.13%

Source: Kimberly-Clark Professional (KleenGuard is an Ansell brand since July 2024) published data (gotopac_a70_tds.txt, opticsplanet_kleenguard_catalogue.txt), copied as published. The employer's hazard assessment under OSHA 29 CFR 1910.132 decides what a job needs; these are the manufacturer's test results, not a fitness statement for any task.

Manufacturer limitations and warnings

  • Coveralls shall be made in accordance with reasonable industry practice with respect to holes, tears, wrinkles, cleanliness, and foreign materials or dirt.
  • ▲Fabric passes penetration testing; however, the chemical is a known or suspected carcinogen or skin absorbed toxin.

KleenGuard A70 questions

What is KleenGuard A70 made of? Polyethylene film (1.5 mil) and spunbond polypropylene fabric; PRODUCT MATERIAL Polyethylene/ non-woven polypropylene laminate; WEIGHT 75gsm; SEAM TYPE Bound; COLOR Yellow; COUNTRY OF ORIGIN Mexico

Which KleenGuard A70 garments does Bayshore Safety carry? 09815 (KleenGuard 9815 A70 Chemical Splash Protection Coveralls).

What standards does the manufacturer name for KleenGuard A70? ASTM F1670 / ASTM F1671; NFPA 99; CPSC 1610; ASTM F903 / ASTM F739; EU (A70/A71 CE versions) — selector table. The wording for each is in the standards table above.

Does the manufacturer publish chemical test data for KleenGuard A70? Yes: 2 tables on this page (Liquid Chemicals Resistance Test; Chemical Resistance Information Guide — KLEENGUARD* A70 Chemical Spray Protection (organized by ASTM F1186 class)), copied from the manufacturer. Penetration and permeation are different tests; the guide on permeation versus penetration explains how to read them.

What does the manufacturer warn about KleenGuard A70? Coveralls shall be made in accordance with reasonable industry practice with respect to holes, tears, wrinkles, cleanliness, and foreign materials or dirt. ▲Fabric passes penetration testing; however, the chemical is a known or suspected carcinogen or skin absorbed toxin.

Is this a statement that the garment is compliant for my job? No. These are the manufacturer's published test results and the standards it names. Under OSHA 29 CFR 1910.132 the employer's hazard assessment decides which protective clothing a task needs.

See also: the disposable coverall fabrics hub, the disposable garment selector and the disposable coverall guides.

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.