BW Technologies / Honeywell Analytics Calibration Gas & Kits
21 calibration gas & kits from BW Technologies / Honeywell Analytics, listed with what BW Technologies / Honeywell Analytics publishes, and live prices.
Pick a gas, number of gases, sampling or battery; the list below narrows as you choose. Prices are live.

21 products
Ratings and specifications are as published by each manufacturer. Tap a group to open it.
BW Technologies / Honeywell Analytics21 products
Open the BW Technologies / Honeywell Analytics page
- BW Technologies 135643-L3 Calibration Gas & Kits, Honeywell BW — BW Technologies / Honeywell Analytics
- BW Technologies C2-HOSE1-1 Calibration Gas & Kits, Honeywell BW 1' — BW Technologies / Honeywell Analytics
- BW Technologies C2-HOSE1-5 Calibration Gas & Kits, Honeywell BW 5' — BW Technologies / Honeywell Analytics
- BW Technologies CG-BUMP-B-K Honeywell BW Balloon Assembly Kit For Calibration — BW Technologies / Honeywell Analytics
- BW Technologies CG-Q34-4 Calibration Gas & Kits, Honeywell BW 25PPM — BW Technologies / Honeywell Analytics
- BW Technologies CK2-CASE1 Calibration Gas & Kits, Honeywell BW — BW Technologies / Honeywell Analytics
- BW Technologies DOCK2-CC1 Calibration Gas & Kits, Honeywell BW — BW Technologies / Honeywell Analytics
- BW Technologies DX-BWC4 Gas Monitor Accessories, Honeywell BW IntelliDoX Docking — BW Technologies / Honeywell Analytics
- BW Technologies DX-CLIP Gas Monitor Accessories, Honeywell BW IntelliDoX Docking — BW Technologies / Honeywell Analytics
- BW Technologies DX-MAXXT Gas Monitor Accessories, Honeywell BW IntelliDoX — BW Technologies / Honeywell Analytics
- BW Technologies DX-MCLP Gas Monitor Accessories, Honeywell BW IntelliDoX Docking — BW Technologies / Honeywell Analytics
- BW Technologies DX-MI-KEY Calibration Gas & Kits, Honeywell BW — BW Technologies / Honeywell Analytics · Approvals: EMC Directive 2014/30/EU
- BW Technologies DX-NEST-CLIP Calibration Gas & Kits, Honeywell BW — BW Technologies / Honeywell Analytics · Approvals: EMC Directive 2014/30/EU
- BW Technologies DX-NEST-MAXXT Calibration Gas & Kits, Honeywell BW — BW Technologies / Honeywell Analytics · Approvals: EMC Directive 2014/30/EU
- BW Technologies DX-SOLO Gas Monitor Accessories, Honeywell BW IntelliDoX Docking — BW Technologies / Honeywell Analytics
- BW Technologies DX-STAND Calibration Gas & Kits, Honeywell BW — BW Technologies / Honeywell Analytics · Approvals: EMC Directive 2014/30/EU
- BW Technologies DX-ULTRA Gas Monitor Accessories, Honeywell BW IntelliDoX — BW Technologies / Honeywell Analytics
- BW Technologies MK-CG2-58 Calibration Gas & Kits, Honeywell BW Wall — BW Technologies / Honeywell Analytics
- BW Technologies REG-0.5 Calibration Gas & Kits, Honeywell BW .5 LPM — BW Technologies / Honeywell Analytics
- BW Technologies REG-1.0 Calibration Gas & Kits, Honeywell BW — BW Technologies / Honeywell Analytics
- BW Technologies REG-DF-3 Calibration Gas & Kits, Honeywell BW — BW Technologies / Honeywell Analytics
Do not see what you need? Browse the category or call (925) 215-7337.
In plain words. A gas monitor is described by the gases it detects (LEL for combustibles, O2 for oxygen, H2S, CO, and so on), how many it detects at once, whether it samples by diffusion (air reaches the sensors on its own) or with a pump (sample draw, for checking a space before entry), how it is powered, and the approvals that let it be used in a classified area. All of these are the manufacturer's published specifications; alarm points and calibration intervals follow the manufacturer's manual.
Technical. Intrinsic-safety approvals are listed as the manufacturer prints them (UL or CSA Class I Division 1 Groups A–D, ATEX and IECEx Ex ia IIC T4 marks). Sensor ranges are quoted per gas (for example 0–100% LEL, 0–30% volume O2, 0–100 ppm H2S, 0–500 ppm CO; PID sensors for VOCs in ppm or ppb with the lamp energy in eV; IR sensors for CO2 or methane). Calibration gas is matched to the monitor's sensors and listed by concentration. Draeger detector tubes have their own finder page.
Ratings and specifications on this page are shown as published by the manufacturer or the named standard and describe performance in that standard's test. They are not a recommendation for any task. The employer's hazard assessment decides what protective equipment a job needs. Verify details against the manufacturer's current documentation before you buy.
The standard at a glance
Copied from the named standard or regulation and shown with its source; nothing in these tables is Bayshore's recommendation.
OSHA confined-space atmosphere limits
| Condition (29 CFR 1910.146) | Limit |
|---|---|
| Oxygen deficient | Below 19.5% oxygen |
| Oxygen enriched | Above 23.5% oxygen |
| Flammable | Above 10% of the lower flammable limit (LFL) |
| Toxic | Above the substance's permissible exposure limit (29 CFR 1910 Subpart Z) |
| Approval mark (as printed by the manufacturer) | Meaning |
|---|---|
| UL or CSA Class I, Division 1, Groups A–D | Intrinsically safe for flammable gas and vapour atmospheres (North America) |
| ATEX / IECEx Ex ia IIC T4 | Intrinsically safe, gas group IIC, temperature class T4 (Europe / international) |
Source: OSHA 29 CFR 1910.146 (permit-required confined spaces). Alarm set points and calibration intervals follow each manufacturer's manual. Draeger detector tubes have their own finder.