BW Technologies / Honeywell Analytics Single-Gas Monitors
42 single-gas monitors from BW Technologies / Honeywell Analytics, listed with what BW Technologies / Honeywell Analytics publishes, and live prices.
Pick a gas, number of gases, sampling or battery; the list below narrows as you choose. Prices are live.

42 products
Ratings and specifications are as published by each manufacturer. Tap a group to open it.
BW Technologies / Honeywell Analytics42 products
Open the BW Technologies / Honeywell Analytics page
- BW Technologies BWC2-H515 Single Gas Monitors, Honeywell BW Clip Portable — BW Technologies / Honeywell Analytics · Gases detected: H2S · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D
- BW Technologies BWC2-M Single Gas Monitors, / Honeywell Analytics BW Clip — BW Technologies / Honeywell Analytics · Gases detected: CO · Gases: 1 gas · Sampling: Diffusion
- BW Technologies BWC2-M25100 Single Gas Monitors, Honeywell BW Clip Portable — BW Technologies / Honeywell Analytics · Gases detected: CO · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D
- BW Technologies BWC2-M50200 Single Gas Monitors, Honeywell BW Clip Portable — BW Technologies / Honeywell Analytics · Gases detected: CO · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D
- BW Technologies BWC2-S Single Gas Monitors, Honeywell BW Clip Portable Sulfur — BW Technologies / Honeywell Analytics · Gases detected: SO2 · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D
- BW Technologies BWC2-S24 Single Gas Monitors, Honeywell BW Clip Portable Sulfur — BW Technologies / Honeywell Analytics · Gases detected: SO2 · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D
- BW Technologies BWC2-X Single Gas Monitors, / Honeywell Analytics BW Clip — BW Technologies / Honeywell Analytics · Gases detected: O2 · Gases: 1 gas · Sampling: Diffusion
- BW Technologies BWC2R-H Single Gas Monitors, Honeywell BW Clip Real Time — BW Technologies / Honeywell Analytics · Gases detected: H2S · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D
- BW Technologies BWC2R-H510 Single Gas Monitors, Honeywell BW Clip Real Time — BW Technologies / Honeywell Analytics · Gases detected: H2S · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D
- BW Technologies BWC2R-M Single Gas Monitors, Honeywell BW Clip Real Time — BW Technologies / Honeywell Analytics · Gases detected: CO · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D
- BW Technologies BWC2R-M25100 Single Gas Monitors, Honeywell BW Clip Real Time — BW Technologies / Honeywell Analytics · Gases detected: CO · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D
- BW Technologies BWC2R-S Single Gas Monitors, Honeywell BW Clip Real Time — BW Technologies / Honeywell Analytics · Gases detected: SO2 · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D
- BW Technologies BWC2R-X Single Gas Monitors, Honeywell BW Clip Real Time — BW Technologies / Honeywell Analytics · Gases detected: O2 · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D
- BW Technologies BWC3-H Single Gas Monitors, Honeywell BW Clip Portable Oxygen — BW Technologies / Honeywell Analytics · Gases detected: O2; H2S · Gases: 2 gases · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D
- BW Technologies BWC3-H510 Single Gas Monitors, Honeywell BW Clip Portable — BW Technologies / Honeywell Analytics · Gases detected: H2S · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D
- BW Technologies BWC3-M Single Gas Monitors, Honeywell BW Clip Portable Carbon — BW Technologies / Honeywell Analytics · Gases detected: CO · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D
- BW Technologies BWC3R-M Single Gas Monitors, Honeywell BW Clip Real Time — BW Technologies / Honeywell Analytics · Gases detected: CO · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D
- BW Technologies BWS-TC-1 Single Gas Monitors, Honeywell BW Solo Portable Ammonia — BW Technologies / Honeywell Analytics · Gases detected: NH3 · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D, T4
- BW Technologies BWS1-A-Y Single Gas Monitors, Honeywell BW Solo Portable Ammonia — BW Technologies / Honeywell Analytics · Gases detected: NH3 · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D, T4
- BW Technologies BWS1-A2-Y Single Gas Monitors, Honeywell BW Solo Portable — BW Technologies / Honeywell Analytics · Gases detected: NH3 · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D, T4
- BW Technologies BWS1-BL-Y Single Gas Monitors, Honeywell BW Solo Portable Carbon — BW Technologies / Honeywell Analytics · Gases detected: CO2 · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D, T4
- BW Technologies BWS1-C-Y Single Gas Monitors, Honeywell BW Solo Portable — BW Technologies / Honeywell Analytics · Gases detected: Cl2 · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D, T4
- BW Technologies BWS1-D-B Single Gas Monitors, Honeywell BW Solo Portable — BW Technologies / Honeywell Analytics · Gases detected: NO2 · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D, T4
- BW Technologies BWS1-G-Y Single Gas Monitors, Honeywell BW Solo Portable Ozone — BW Technologies / Honeywell Analytics · Gases detected: O3 · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D, T4
- BW Technologies BWS1-HL-B Single Gas Monitors, Honeywell BW Solo Portable — BW Technologies / Honeywell Analytics · Gases detected: H2S · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D, T4
- BW Technologies BWS1-HL-Y Single Gas Monitors, Honeywell BW Solo Portable — BW Technologies / Honeywell Analytics · Gases detected: H2S · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D, T4
- BW Technologies BWS1-M2-Y Single Gas Monitors, Honeywell BW Solo Portable Carbon — BW Technologies / Honeywell Analytics · Gases detected: CO · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D, T4
- BW Technologies BWS1-ML-Y Single Gas Monitors, Honeywell BW Solo Portable Carbon — BW Technologies / Honeywell Analytics · Gases detected: CO · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D, T4
- BW Technologies BWS1-P-Y Single Gas Monitors, Honeywell BW Solo Portable — BW Technologies / Honeywell Analytics · Gases detected: PH3 · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D, T4
- BW Technologies BWS1-S-Y Single Gas Monitors, Honeywell BW Solo Portable Sulfur — BW Technologies / Honeywell Analytics · Gases detected: SO2 · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D, T4
- BW Technologies BWS1-V-Y Single Gas Monitors, Honeywell BW Solo Portable — BW Technologies / Honeywell Analytics · Gases detected: Cl2; ClO2 · Gases: 2 gases · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D, T4
- BW Technologies BWS1-XL-Y Single Gas Monitors, Honeywell BW Solo Portable Oxygen — BW Technologies / Honeywell Analytics · Gases detected: O2 · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D, T4
- BW Technologies BWS1-Z-B Single Gas Monitors, Honeywell BW Solo Portable — BW Technologies / Honeywell Analytics · Gases detected: HCN · Gases: 1 gas · Sampling: Diffusion · Approvals: Class I Div 1 Groups A, B, C, D, T4
- BW Technologies BWS1-Z-Y Single Gas Monitors, / Honeywell Analytics BW Solo — BW Technologies / Honeywell Analytics · Gases detected: HCN · Gases: 1 gas · Sampling: Diffusion
- BW Technologies CP-I-000000S3-Y-00 Single Gas Monitors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: SO2 · Gases: 1 gas · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CP-I-0000H100-Y-00 Single Gas Monitors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: H2S · Gases: 1 gas · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CP-I-00X10000-Y-00 Single Gas Monitors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: O2 · Gases: 1 gas · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CP-I-00X100M1-Y-00 Single Gas Monitors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: CO · Gases: 1 gas · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CP-I-W5000000-Y-00 Single Gas Monitors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: LEL · Gases: 1 gas · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies Single Gas Monitors, / Honeywell Analytics BW Clip Single-Gas — BW Technologies / Honeywell Analytics · Gases detected: H2S · Gases: 1 gas · Sampling: Diffusion · Battery: Sealed (non-replaceable)
- BW Technologies XT-00H0-Y-NA Single Gas Monitors, Honeywell BW GasAlertMax XT II — BW Technologies / Honeywell Analytics · Gases detected: H2S · Gases: 1 gas · Sampling: Pump (sample draw) · Battery: Li-Ion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; BR-Ex ia IIC T4; IECEx Ex ia IIC T4 Ga; UL Class I Div 1 Groups A, B, C, D
- BW Technologies XT-X000-Y-NA Single Gas Monitors, Honeywell BW Max XT II — BW Technologies / Honeywell Analytics · Gases detected: O2 · Gases: 1 gas · Sampling: Pump (sample draw) · Battery: Li-Ion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; BR-Ex ia IIC T4; IECEx Ex ia IIC T4 Ga; UL Class I Div 1 Groups A, B, C, D
Do not see what you need? Browse the category or call (925) 215-7337.
In plain words. A gas monitor is described by the gases it detects (LEL for combustibles, O2 for oxygen, H2S, CO, and so on), how many it detects at once, whether it samples by diffusion (air reaches the sensors on its own) or with a pump (sample draw, for checking a space before entry), how it is powered, and the approvals that let it be used in a classified area. All of these are the manufacturer's published specifications; alarm points and calibration intervals follow the manufacturer's manual.
Technical. Intrinsic-safety approvals are listed as the manufacturer prints them (UL or CSA Class I Division 1 Groups A–D, ATEX and IECEx Ex ia IIC T4 marks). Sensor ranges are quoted per gas (for example 0–100% LEL, 0–30% volume O2, 0–100 ppm H2S, 0–500 ppm CO; PID sensors for VOCs in ppm or ppb with the lamp energy in eV; IR sensors for CO2 or methane). Calibration gas is matched to the monitor's sensors and listed by concentration. Draeger detector tubes have their own finder page.
Ratings and specifications on this page are shown as published by the manufacturer or the named standard and describe performance in that standard's test. They are not a recommendation for any task. The employer's hazard assessment decides what protective equipment a job needs. Verify details against the manufacturer's current documentation before you buy.
The standard at a glance
Copied from the named standard or regulation and shown with its source; nothing in these tables is Bayshore's recommendation.
OSHA confined-space atmosphere limits
| Condition (29 CFR 1910.146) | Limit |
|---|---|
| Oxygen deficient | Below 19.5% oxygen |
| Oxygen enriched | Above 23.5% oxygen |
| Flammable | Above 10% of the lower flammable limit (LFL) |
| Toxic | Above the substance's permissible exposure limit (29 CFR 1910 Subpart Z) |
| Approval mark (as printed by the manufacturer) | Meaning |
|---|---|
| UL or CSA Class I, Division 1, Groups A–D | Intrinsically safe for flammable gas and vapour atmospheres (North America) |
| ATEX / IECEx Ex ia IIC T4 | Intrinsically safe, gas group IIC, temperature class T4 (Europe / international) |
Source: OSHA 29 CFR 1910.146 (permit-required confined spaces). Alarm set points and calibration intervals follow each manufacturer's manual. Draeger detector tubes have their own finder.