Industrial Scientific Replacement Sensors
13 replacement sensors from Industrial Scientific, listed with what Industrial Scientific publishes, and live prices.
Pick a gas, number of gases, sampling or battery; the list below narrows as you choose. Prices are live.

13 products
Ratings and specifications are as published by each manufacturer. Tap a group to open it.
Industrial Scientific13 products
Open the Industrial Scientific page
- Industrial Scientific 17124975-3 MX6 iBrid Oxygen (O2) Replacement Sensor — Industrial Scientific · Gases detected: O2
- Industrial Scientific 17124975-4 MX6 iBrid Nitrogen Dioxide (NO2) Replacement — Industrial Scientific · Gases detected: Nitrogen Dioxide (NO2)
- Industrial Scientific 17124975-5 MX6 iBrid Sulfur Dioxide (SO2) Replacement — Industrial Scientific · Gases detected: SO2
- Industrial Scientific 17124975-6 MX6 iBrid Replacement Ammonia Sensor — Industrial Scientific · Gases detected: NH3
- Industrial Scientific 17124975-J MX6 iBrid Replacement CO/H2S Dual Sensor — Industrial Scientific · Gases detected: H2S; CO
- Industrial Scientific 17124975-K MX6 iBrid LEL Pentane Replacement Sensor — Industrial Scientific · Gases detected: LEL; Pentane
- Industrial Scientific 17124975-L MX6 iBrid LEL Methane Replacement Sensor — Industrial Scientific · Gases detected: LEL; CH4 (IR)
- Industrial Scientific 17124975-R MX6 iBrid PID VOC Replacement Sensor — Industrial Scientific · Gases detected: VOC (PID)
- Industrial Scientific 17134461 Ventis MX4 Oxygen (O2) Replacement Sensor — Industrial Scientific · Gases detected: O2
- Industrial Scientific 17134479 Ventis MX4 Hydrogen Sulfide (H2S) Replacement — Industrial Scientific · Gases detected: H2S
- Industrial Scientific 17134487 Ventis MX4 Carbon Monoxide (CO) Replacement — Industrial Scientific · Gases detected: CO
- Industrial Scientific 17134495 Ventis MX4 LEL Methane Replacement Sensor — Industrial Scientific · Gases detected: LEL; CH4 (IR)
- Industrial Scientific 17155304-3 Ventis Pro Oxygen (O2) Replacement Sensor — Industrial Scientific · Gases detected: O2
Do not see what you need? Browse the category or call (925) 215-7337.
In plain words. A gas monitor is described by the gases it detects (LEL for combustibles, O2 for oxygen, H2S, CO, and so on), how many it detects at once, whether it samples by diffusion (air reaches the sensors on its own) or with a pump (sample draw, for checking a space before entry), how it is powered, and the approvals that let it be used in a classified area. All of these are the manufacturer's published specifications; alarm points and calibration intervals follow the manufacturer's manual.
Technical. Intrinsic-safety approvals are listed as the manufacturer prints them (UL or CSA Class I Division 1 Groups A–D, ATEX and IECEx Ex ia IIC T4 marks). Sensor ranges are quoted per gas (for example 0–100% LEL, 0–30% volume O2, 0–100 ppm H2S, 0–500 ppm CO; PID sensors for VOCs in ppm or ppb with the lamp energy in eV; IR sensors for CO2 or methane). Calibration gas is matched to the monitor's sensors and listed by concentration. Draeger detector tubes have their own finder page.
Ratings and specifications on this page are shown as published by the manufacturer or the named standard and describe performance in that standard's test. They are not a recommendation for any task. The employer's hazard assessment decides what protective equipment a job needs. Verify details against the manufacturer's current documentation before you buy.
The standard at a glance
Copied from the named standard or regulation and shown with its source; nothing in these tables is Bayshore's recommendation.
OSHA confined-space atmosphere limits
| Condition (29 CFR 1910.146) | Limit |
|---|---|
| Oxygen deficient | Below 19.5% oxygen |
| Oxygen enriched | Above 23.5% oxygen |
| Flammable | Above 10% of the lower flammable limit (LFL) |
| Toxic | Above the substance's permissible exposure limit (29 CFR 1910 Subpart Z) |
| Approval mark (as printed by the manufacturer) | Meaning |
|---|---|
| UL or CSA Class I, Division 1, Groups A–D | Intrinsically safe for flammable gas and vapour atmospheres (North America) |
| ATEX / IECEx Ex ia IIC T4 | Intrinsically safe, gas group IIC, temperature class T4 (Europe / international) |
Source: OSHA 29 CFR 1910.146 (permit-required confined spaces). Alarm set points and calibration intervals follow each manufacturer's manual. Draeger detector tubes have their own finder.