MSA Batteries & Chargers
23 batteries & chargers from MSA, listed with what MSA publishes, and live prices.
Pick a gas, number of gases, sampling or battery; the list below narrows as you choose. Prices are live.

23 products
Ratings and specifications are as published by each manufacturer. Tap a group to open it.
MSA23 products
- MSA 10049059 Batteries & Chargers, ALTAIR Sample Line Adapter For Sirius Series — MSA
- MSA 10074132 Batteries & Chargers, Altair Battery For Altair Pro Single Gas — MSA
- MSA 10086639 Batteries & Chargers, Altair 4 Charging Cradle For Altair — MSA
- MSA 10087913 Batteries & Chargers, ALTAIR 4X / 4XR / 5X Wall Charger — MSA
- MSA 10092233 Batteries & Chargers, Altair 4 Charging Cradle — MSA
- MSA 10092936 Batteries & Chargers, Altair 4 Global Charger For Altair — MSA
- MSA 10093053 Batteries & Chargers, Altair 5 Cradle Charger Assembly For Altair — MSA
- MSA 10093054 Batteries & Chargers, Altair 5 Charging Cradle For Altair — MSA
- MSA 10095774 Batteries & Chargers, Plastic ALTAIR 4 Charging Cradle For ALTAIR — MSA
- MSA 10099397 Batteries & Chargers, Plastic Altair 5/5X Vehicle Charger — MSA
- MSA 10110183 Batteries & Chargers, Adapter For Altair 5X Multi-Gas Detector — MSA
- MSA 10114835 Batteries & Chargers, Altair 5X Battery And Battery Charger — MSA
- MSA 10114837 Batteries & Chargers, Plastic Altair 5/5X Battery Pack For Altair — MSA
- MSA 10114839 Batteries & Chargers, ALTAIR 5X Rechargeable Battery Pack Assembly — MSA
- MSA 10124286 Batteries & Chargers, Power Supply — MSA
- MSA 10127422 Batteries & Chargers, Plastic GALAXY GX2 ALTAIR 4/4X Detector — MSA
- MSA 10127427 Batteries & Chargers, Plastic GALAXY GX2 ALTAIR 4/4X Detector — MSA
- MSA 10155203-SP Batteries & Chargers, Altair 2X Battery For Altair 2X — MSA
- MSA 10161803 Batteries & Chargers, Multi Unit Charger For Altair 5X/4X Multi-Gas — MSA
- MSA 10242927 Batteries & Chargers, Polycarbonate ALTAIR io 4 5-Device Smart — MSA
- MSA 10250799 Batteries & Chargers, ALTAIR io 6 Portable Detector Battery Pack — MSA
- MSA 10253408 Batteries & Chargers, Plastic Black ALTAIR io Multigas Charging — MSA
- MSA M-20020 Batteries & Chargers, Battery Pack Assembly For C420 Powered Air — MSA
Do not see what you need? Browse the category or call (925) 215-7337.
In plain words. A gas monitor is described by the gases it detects (LEL for combustibles, O2 for oxygen, H2S, CO, and so on), how many it detects at once, whether it samples by diffusion (air reaches the sensors on its own) or with a pump (sample draw, for checking a space before entry), how it is powered, and the approvals that let it be used in a classified area. All of these are the manufacturer's published specifications; alarm points and calibration intervals follow the manufacturer's manual.
Technical. Intrinsic-safety approvals are listed as the manufacturer prints them (UL or CSA Class I Division 1 Groups A–D, ATEX and IECEx Ex ia IIC T4 marks). Sensor ranges are quoted per gas (for example 0–100% LEL, 0–30% volume O2, 0–100 ppm H2S, 0–500 ppm CO; PID sensors for VOCs in ppm or ppb with the lamp energy in eV; IR sensors for CO2 or methane). Calibration gas is matched to the monitor's sensors and listed by concentration. Draeger detector tubes have their own finder page.
Ratings and specifications on this page are shown as published by the manufacturer or the named standard and describe performance in that standard's test. They are not a recommendation for any task. The employer's hazard assessment decides what protective equipment a job needs. Verify details against the manufacturer's current documentation before you buy.
The standard at a glance
Copied from the named standard or regulation and shown with its source; nothing in these tables is Bayshore's recommendation.
OSHA confined-space atmosphere limits
| Condition (29 CFR 1910.146) | Limit |
|---|---|
| Oxygen deficient | Below 19.5% oxygen |
| Oxygen enriched | Above 23.5% oxygen |
| Flammable | Above 10% of the lower flammable limit (LFL) |
| Toxic | Above the substance's permissible exposure limit (29 CFR 1910 Subpart Z) |
| Approval mark (as printed by the manufacturer) | Meaning |
|---|---|
| UL or CSA Class I, Division 1, Groups A–D | Intrinsically safe for flammable gas and vapour atmospheres (North America) |
| ATEX / IECEx Ex ia IIC T4 | Intrinsically safe, gas group IIC, temperature class T4 (Europe / international) |
Source: OSHA 29 CFR 1910.146 (permit-required confined spaces). Alarm set points and calibration intervals follow each manufacturer's manual. Draeger detector tubes have their own finder.