MSA Replacement Sensors
26 replacement sensors from MSA, listed with what MSA publishes, and live prices.
Pick a gas, number of gases, sampling or battery; the list below narrows as you choose. Prices are live.

26 products
Ratings and specifications are as published by each manufacturer. Tap a group to open it.
MSA26 products
- MSA 10001-1 Replacement Sensor for — MSA
- MSA 10046946 Replacement Oxygen Sensor for Solaris — MSA
- MSA 10049806 Replacement Oxygen Sensor for Sirius — MSA
- MSA 10080224 Replacement Sensor for Altair 5/5X — MSA
- MSA 10089163 Replacement Oxygen Sensor for Altair 4, Altair 5 — MSA
- MSA 10105650 Replacement Sensor for XCell — MSA
- MSA 10106375 Replacement Hydrogen Cyanide Sensor for Altair, Altair 5X — MSA
- MSA 10106726 Replacement Ammonia Sensor for Altair 4X, Altair 5X — MSA
- MSA 10106727 Replacement Sensor for XCell — MSA
- MSA 10106728 Replacement Chlorine Sensor for Altair, XCell, Altair 5X — MSA
- MSA 10110062 Replacement Sensor — MSA
- MSA 10114750 Replacement Sensor for Altair, Altair 5X, XCell — MSA
- MSA 10116638 Replacement Phosphine Sensor for Altair 5X, Altair — MSA
- MSA 10121211 Replacement Sensor — MSA
- MSA 10121212 Replacement Combustible Gas (LEL) Sensor for XCell — MSA
- MSA 10121213 Replacement Hydrogen Sulfide / Carbon Monoxide Sensor for XCell — MSA
- MSA 10121215 Replacement Hydrogen Sulfide / Sulfur Dioxide Sensor for XCell — MSA
- MSA 10121216 Replacement Sensor for ALTAIR — MSA
- MSA 10121217 Replacement Carbon Monoxide / Nitrogen Dioxide Sensor for XCell — MSA
- MSA 10121227 Replacement Hydrogen Sulfide Sensor for XCell — MSA
- MSA 10152603 Replacement Hydrogen Sulfide / Carbon Monoxide Sensor for XCell — MSA
- MSA 10152606 Replacement Carbon Monoxide / Nitrogen Dioxide Sensor for XCell — MSA
- MSA 10242735 Replacement Sensor for Altair 5X — MSA
- MSA 1400152-1 Replacement Sensor — MSA
- MSA 813777 Replacement Oxygen Sensor — MSA
- MSA A-ULTX-SENS1410 Ultima X Series Oxygen (O2) Replacement Sensor, 0-25% — MSA · Gases detected: O2
Do not see what you need? Browse the category or call (925) 215-7337.
In plain words. A gas monitor is described by the gases it detects (LEL for combustibles, O2 for oxygen, H2S, CO, and so on), how many it detects at once, whether it samples by diffusion (air reaches the sensors on its own) or with a pump (sample draw, for checking a space before entry), how it is powered, and the approvals that let it be used in a classified area. All of these are the manufacturer's published specifications; alarm points and calibration intervals follow the manufacturer's manual.
Technical. Intrinsic-safety approvals are listed as the manufacturer prints them (UL or CSA Class I Division 1 Groups A–D, ATEX and IECEx Ex ia IIC T4 marks). Sensor ranges are quoted per gas (for example 0–100% LEL, 0–30% volume O2, 0–100 ppm H2S, 0–500 ppm CO; PID sensors for VOCs in ppm or ppb with the lamp energy in eV; IR sensors for CO2 or methane). Calibration gas is matched to the monitor's sensors and listed by concentration. Draeger detector tubes have their own finder page.
Ratings and specifications on this page are shown as published by the manufacturer or the named standard and describe performance in that standard's test. They are not a recommendation for any task. The employer's hazard assessment decides what protective equipment a job needs. Verify details against the manufacturer's current documentation before you buy.
The standard at a glance
Copied from the named standard or regulation and shown with its source; nothing in these tables is Bayshore's recommendation.
OSHA confined-space atmosphere limits
| Condition (29 CFR 1910.146) | Limit |
|---|---|
| Oxygen deficient | Below 19.5% oxygen |
| Oxygen enriched | Above 23.5% oxygen |
| Flammable | Above 10% of the lower flammable limit (LFL) |
| Toxic | Above the substance's permissible exposure limit (29 CFR 1910 Subpart Z) |
| Approval mark (as printed by the manufacturer) | Meaning |
|---|---|
| UL or CSA Class I, Division 1, Groups A–D | Intrinsically safe for flammable gas and vapour atmospheres (North America) |
| ATEX / IECEx Ex ia IIC T4 | Intrinsically safe, gas group IIC, temperature class T4 (Europe / international) |
Source: OSHA 29 CFR 1910.146 (permit-required confined spaces). Alarm set points and calibration intervals follow each manufacturer's manual. Draeger detector tubes have their own finder.