RKI Instruments Replacement Sensors
15 replacement sensors from RKI Instruments, listed with what RKI Instruments publishes, and live prices.
Pick a gas, number of gases, sampling or battery; the list below narrows as you choose. Prices are live.

15 products
Ratings and specifications are as published by each manufacturer. Tap a group to open it.
RKI Instruments15 products
- RKI Instruments 21-1983 Sensor Retainer for GX-Force — RKI Instruments
- RKI Instruments ES-1821 Carbon Monoxide (CO) Sensor for and — RKI Instruments
- RKI Instruments ESR-A13D-HCN (Hydrogen Cyanide) Sensor ESR-A13D for GX-3R — RKI Instruments · Gases detected: HCN
- RKI Instruments ESR-A13D-NO2 (Nitrogen Dioxide) Sensor ESR-A13D for GX-3R — RKI Instruments · Gases detected: NO2
- RKI Instruments ESR-A13I-H2S (Hydrogen Sulfide) Sensor ESR-A13i for GX-3R — RKI Instruments · Gases detected: H2S
- RKI Instruments ESR-A13P-CO (Carbon Monoxide) Sensor ESR-A13P for GX-3R — RKI Instruments · Gases detected: CO
- RKI Instruments ESR-A1CP-CO-H H2-Compensated CO Sensor ESR-A1CP for GX-3R — RKI Instruments · Gases detected: CO
- RKI Instruments ESR-A1DP-COHS H2S/CO Combination Sensor ESR-A1DP for GX-3R — RKI Instruments · Gases detected: H2S; CO
- RKI Instruments ESR-B134-NH3 (Ammonia) Sensor ESR-B134 for GX-3R Pro — RKI Instruments · Gases detected: NH3
- RKI Instruments ESR-X13P-OXY O2 (Oxygen) Sensor ESR-X13P for GX-3R & GX-3R Pro — RKI Instruments · Gases detected: O2
- RKI Instruments IRR-0409 CO2 Infrared Sensor 0-10% vol, for GX-3R Pro — RKI Instruments · Gases detected: CO2
- RKI Instruments IRR-0433 CO2 Infrared Sensor 0-10, 000 ppm, for GX-3R Pro — RKI Instruments · Gases detected: CO2
- RKI Instruments NC-6264A Combustible Gas (LEL) Sensor for and — RKI Instruments
- RKI Instruments NCR-6309 LEL (Combustible) Sensor for GX-3R & GX-3R Pro — RKI Instruments · Gases detected: LEL
- RKI Instruments PID-002LA PID Sensor 10.6 eV Plug-In, 0-4, 000 ppm VOC — RKI Instruments · Gases detected: VOC (PID)
Do not see what you need? Browse the category or call (925) 215-7337.
In plain words. A gas monitor is described by the gases it detects (LEL for combustibles, O2 for oxygen, H2S, CO, and so on), how many it detects at once, whether it samples by diffusion (air reaches the sensors on its own) or with a pump (sample draw, for checking a space before entry), how it is powered, and the approvals that let it be used in a classified area. All of these are the manufacturer's published specifications; alarm points and calibration intervals follow the manufacturer's manual.
Technical. Intrinsic-safety approvals are listed as the manufacturer prints them (UL or CSA Class I Division 1 Groups A–D, ATEX and IECEx Ex ia IIC T4 marks). Sensor ranges are quoted per gas (for example 0–100% LEL, 0–30% volume O2, 0–100 ppm H2S, 0–500 ppm CO; PID sensors for VOCs in ppm or ppb with the lamp energy in eV; IR sensors for CO2 or methane). Calibration gas is matched to the monitor's sensors and listed by concentration. Draeger detector tubes have their own finder page.
Ratings and specifications on this page are shown as published by the manufacturer or the named standard and describe performance in that standard's test. They are not a recommendation for any task. The employer's hazard assessment decides what protective equipment a job needs. Verify details against the manufacturer's current documentation before you buy.
The standard at a glance
Copied from the named standard or regulation and shown with its source; nothing in these tables is Bayshore's recommendation.
OSHA confined-space atmosphere limits
| Condition (29 CFR 1910.146) | Limit |
|---|---|
| Oxygen deficient | Below 19.5% oxygen |
| Oxygen enriched | Above 23.5% oxygen |
| Flammable | Above 10% of the lower flammable limit (LFL) |
| Toxic | Above the substance's permissible exposure limit (29 CFR 1910 Subpart Z) |
| Approval mark (as printed by the manufacturer) | Meaning |
|---|---|
| UL or CSA Class I, Division 1, Groups A–D | Intrinsically safe for flammable gas and vapour atmospheres (North America) |
| ATEX / IECEx Ex ia IIC T4 | Intrinsically safe, gas group IIC, temperature class T4 (Europe / international) |
Source: OSHA 29 CFR 1910.146 (permit-required confined spaces). Alarm set points and calibration intervals follow each manufacturer's manual. Draeger detector tubes have their own finder.