Bayshore Safety & Industrial Supplies Guide
RTV silicone and gasket makers: 598, 5699, 587 and the anaerobic 518 and 510, temperature limits and cure? What RTV means and how it cures, black, gray, red, blue and copper silicones and what the color tells you, sensor-safe and oxygen-sensor-safe (non-corrosive) formulas, oil resistance, anaerobic flange sealants for rigid machined flanges, bead size and skin time, when a cut gasket is still the answer, and torque after cure
A gasket maker is a sealant applied as a bead to a flange so that it forms the gasket in place, and two chemistries do the job. RTV silicone (room-temperature vulcanizing) is a paste that cures by reacting with moisture in the air, skinning in 10 to 30 minutes and curing through at about 1/8 inch per 24 hours, into a flexible rubber that seals flanges with gaps, movement and stamped covers; it is sold by color, which the makers use as a grade code: black (Loctite 598 and 5900, Permatex Ultra Black) is the oil-resistant, sensor-safe general-purpose gasket maker for oil pans, valve covers and timing covers, to 500 °F intermittent; gray (Loctite 5699, Permatex Ultra Grey) is the high-torque, rigid formula for close-tolerance flanges under high vibration (transmission pans, bell housings), to 500 °F; red (Loctite 596 and 5920 copper, Permatex Ultra Copper and High-Temp Red) is the high-temperature formula for exhaust manifolds, headers and turbo flanges, to 600 °F intermittent (650 for copper); blue (Permatex Sensor-Safe Blue, Loctite 587) is the general-purpose, non-corrosive, sensor-safe silicone for thermostat housings, water pumps and covers, to 500 °F; and clear and white are general sealants, not gasket makers. Sensor-safe means the formula cures without releasing acetic acid (the vinegar smell of acetoxy silicone), which corrodes oxygen sensors and electrical contacts; the oxime and alkoxy cure formulas are the ones labeled for engines. Anaerobic flange sealants (Loctite 518, 510, 515 and 5188) are the other family: they cure without air between two rigid, machined metal flanges with little or no gap (to about .010 inch), form a hard seal that does not shrink or extrude, resist oil and most fluids, and are the choice for cast and machined housings (gear cases, pump bodies, transmission cases) where the flanges meet metal-to-metal; 518 is the general grade to 300 °F, 510 the high-temperature grade to 400 °F, 515 the flexible grade for stamped and flexing flanges, and 5188 the newer general grade with oil tolerance. Application: clean, dry, oil-free flanges; a continuous bead of 1/16 to 1/4 inch around the inside of the bolt holes; assemble within the skin time (RTV) or anytime before cure (anaerobic); torque to spec (for RTV many makers say finger-tight, wait for skin, then torque so the bead is not squeezed out; the data sheet governs), and let RTV cure 24 hours before fluid and full load. RTV is never a substitute for a cut gasket where the design calls for one (head gaskets, carburetor bases, and flanges that set a clearance), and too much RTV squeezes into the oil passages and plugs pickups. The band lists the RTV silicones by color and grade, the anaerobic flange sealants and the gasket removers we stock.
Why the color is on the tube. Silicone gasket makers are all silicone, and the color is how the makers tell the formulas apart: black for oil, gray for torque, red for heat, blue for sensors and water. The second family, the anaerobics, is for the flanges where there is no gap for a rubber bead at all. The two mistakes the data sheets address are too much silicone (it ends up in the oil pickup) and the wrong one on a hot or close-tolerance flange. The cards cover RTV cure, the colors, sensor safety, the anaerobics, application, and when a cut gasket stays.
Gasket makers, question by question
Temperature and cure figures are from the Loctite and Permatex data sheets; the data sheet for the product in hand governs.
In plain words
- RTV cures from air moisture into flexible rubber: skins in minutes, cures 1/8 inch a day; the color is the grade.
- Black for oil (pans, covers); gray for high torque and tight flanges; red and copper for exhaust heat; blue for water and covers.
- Sensor-safe means no acetic acid: never construction silicone on an engine or in an electrical box.
- Anaerobic 518, 510, 515 and 5188 for rigid machined metal flanges with no gap: assemble and torque wet.
- Thin continuous bead inside the bolt holes, circles around the holes, finger-tight, wait, torque, 24 hours before fluid.
- Head gaskets, carburetor bases and anything that sets a clearance keep their cut gasket.
Questions people ask
What is the difference between black, gray and red RTV?
Black is the oil-resistant general gasket maker, gray is the rigid high-torque formula for close flanges, red and copper are the high-temperature formulas for exhaust.
What does sensor-safe mean on RTV?
The cure releases no acetic acid, so it will not poison oxygen sensors or corrode contacts; acetoxy silicone (the vinegar-smelling kind) is not used on engines.
How long does RTV take to cure?
Skin in 10 to 30 minutes; cure about 1/8 inch per 24 hours; the makers say 24 hours before fluid and full load.
When do you use Loctite 518 instead of RTV?
On rigid, machined metal-to-metal flanges with little or no gap, where a rubber bead would be squeezed out; 518 cures without air into a hard seal.
How thick should an RTV bead be?
1/16 to 1/8 inch on a close flange, up to 1/4 inch for gaps, continuous and inside the bolt holes; too much ends up in the oil passages.
Can RTV replace a head gasket?
No; gaskets that set a clearance or crush (head, intake, carburetor base) stay cut gaskets.
Related guides
Threadlocker colors and numbersThe other anaerobicsPipe thread sealant or PTFE tapeSealing the threads into the housingInstant adhesives and structural epoxiesBonding instead of sealingTorque wrench types, accuracy and calibrationTorquing the flangeGloves for isopropyl alcohol, acetone, bleach, acids and fuelsCleaning flangesThe ratings, test results and standards shown here are the manufacturers' published values, reproduced as published. Nothing on this page is a recommendation by Bayshore Safety that any product is suitable for a particular task, hazard or workplace. Selecting safety products and protective equipment is the responsibility of the end user and the employer, based on their own hazard assessment and the regulations that apply to their work. Confirm every value on the manufacturer's own documentation before use.
© 2026 Bayshore Safety & Industrial Supplies, Inc. All rights reserved. This guide may not be copied or republished without written permission.