Description
Microflex 93-260 green nitrile exam gloves, 7.9 mil: 4 part numbers, sizes M to 2XL; nitrile, neoprene; powder-free; 7.9 mil finger thickness, as Ansell prints it. Ansell calls it "Chemical‑resistant disposable gloves that deliver durable protection and comfort". 4 part numbers on this page (93260080, 93260090, 93260100, 93260110): pick the size above and the part number, price and specification change with it. Sold by the dispenser, 50 gloves; the price is for the whole dispenser. Made in Sri Lanka. Ships in 1–2 business days; most orders arrive in 3–7 business days. All the Ansell Microflex nitrile exam gloves we stock are on the Ansell Microflex nitrile exam gloves page.
Microflex 93-260 specifications
From the Ansell product page
| Specification | Ansell |
|---|---|
| EN 388:2016 | 2000X |
| EN ISO 374-1 chemical letters | JKLOPST |
| Also printed | FDA 21 CFR 177.2600-US Food Contact rated |
| Also printed | Category III |
| Also printed | EN ISO 21420:2020 |
| Available Sizes | S (6.5 - 7), M (7.5 - 8), L (8.5 - 9), XL (9.5 - 10), XXL (10.5 - 11), XS (5.5 - 6) |
| Cuff Style | Beaded |
| Cuff Length | Extended |
| Palm Thickness | 0.20 mm / 7.9 mil |
| Finger Thickness | 0.20 mm / 7.9 mil |
| Material | Nitrile, Neoprene |
| Color | Green |
| Powder Content | Powder-Free |
| External Glove Surface | Textured Fingers |
| Freedom from holes (inspection level I) | 0.65 AQL |
| Antistatic | Yes EN1149 |
| Not Made From Natural Rubber Latex | Yes |
| Silicone Free | Yes |
| Allergy Prevention | Latex (Type I) |
| Tested For Use With Chemotherapy Drugs | Yes, in accordance with ASTM D6978 (Not listed in the US FDA 510k) |
| Sterile | No |
| Product Segmentation | High Risk |
Source: Ansell product page (ansell.com, US site), the Standards and certifications block and the Product details as printed: MICROFLEX 93-260 (https://www.ansell.com/us/en/products/microflex-93-260), read Nov 19 2026. ANSI/ISEA 105 and the EN standards are named as the manufacturer prints the markings; they are licensed standards and are not quoted.
Product data
| Specification | Detail |
|---|---|
| Part numbers | 93260080, 93260090, 93260100, 93260110 |
| Style | 93-260 |
| Product type | Disposable gloves |
| Family | Microflex nitrile exam gloves |
| Manufacturer title | MICROFLEX 93-260 |
| Sizes on this page | M, L, XL, 2XL |
| Sizes the manufacturer makes | S (6.5 - 7), M (7.5 - 8), L (8.5 - 9), XL (9.5 - 10), XXL (10.5 - 11), XS (5.5 - 6) |
| Sold by | Dispenser of 50 gloves |
| Country of origin | Sri Lanka |
| Part number | Size | Color | Sold by | UPC | Price |
|---|---|---|---|---|---|
| 93260080 | M | Green | Dispenser of 50 gloves | 00764904534800 | $28.49 |
| 93260090 | L | Green | Dispenser of 50 gloves | 00764904534970 | $28.49 |
| 93260100 | XL | Green | Dispenser of 50 gloves | 076490453503 | $28.49 |
| 93260110 | 2XL | Green | Dispenser of 50 gloves | 00764904535100 | $28.49 |
Source: manufacturer product data (UPC, country of origin, pack, Prop 65) and the live option labels. Figures are as the manufacturer publishes them.
Safe use
Ansell prints: EN 388:2016 2000X; EN ISO 374-1 letters JKLOPST; FDA 21 CFR 177.2600-US Food Contact rated.
Ansell prints the freedom-from-holes level as 0.65 AQL (inspection level I).
Ansell prints: tested for use with chemotherapy drugs, Yes, in accordance with ASTM D6978 (Not listed in the US FDA 510k).
Ansell prints the allergy note as: Latex (Type I).
29 CFR 1910.138(a): employers shall select and require employees to use appropriate hand protection when employees' hands are exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasions; punctures; chemical burns; thermal burns; and harmful temperature extremes.
29 CFR 1910.138(b): employers shall base the selection of the appropriate hand protection on an evaluation of the performance characteristics of the hand protection relative to the task(s) to be performed, conditions present, duration of use, and the hazards and potential hazards identified.
29 CFR 1910.132(d)(1): the employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment; if so, the employer shall select, and have each affected employee use, the types of PPE that will protect the affected employee from the hazards identified in the hazard assessment.
Cal/OSHA Title 8 section 3384(a): hand protection shall be required for employees whose work involves unusual and excessive exposure of hands to cutting, chemicals, materials, and harmful temperature extremes, except that hand protection for cuts, lacerations, and abrasions is not required when the employer's PPE hazard assessment under section 3380(f) finds the risk infrequent and superficial.
Cal/OSHA Title 8 section 3384(b): hand protection, such as gloves, shall not be worn where there is a danger of the hand protection becoming entangled in moving machinery or materials.
29 CFR 1926.95(a) (construction): protective equipment, including protective clothing, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment.
The manufacturer prints the thickness, the AQL (freedom from holes) and the FDA, ASTM and EN markings on this glove as its own test results; those standards are not quoted here. A disposable glove is single use; the manufacturer prints no permeation data for it beyond the markings above.
Source: OSHA 29 CFR 1910.138, 1910.132 and 1926.95 as published on osha.gov; Cal/OSHA Title 8 section 3384 as published on dir.ca.gov; Ansell product page as printed; read Nov 19 2026.
Microflex 93-260, as Ansell describes it
Features:
- Three-layer design: Offering resistance to harsh chemicals
- Thinnest chemical-resistant disposable glove: For tactility and dexterity
- Low AQL: 0.65 AQL for allowable pinholes means barrier integrity
- Three-layer design: Three layers give protection against harsh chemicals
- Tactility: Designed to be thinner than standard reusable chemical-resistant gloves, providing protection while allowing for better tactility when handling small objects and tools
- Elevated comfort: Soft material and ergonomic design offer fit, feel and flexibility
- Assured quality: Their low AQL (0.65) means minimal pinhole defect risks
- High standards: Meets EN 374 Type A rated in Europe and KOSHA rated in Korea
- Retail pack: Available in convenient packaging of 6 gloves, size specific
Ansell lists it for: general purpose auto aftermarket; production line support and maintenance; sample taking and processing; transferring liquids and solids between vessels and tanks and process equipment; oil, fluids and filter change; inspection, selecting, checking parts; assembly and inspection of components; equipment repair and maintenance.
Industries the manufacturer names: Aerospace, Automotive, Automotive Aftermarket, Life Sciences, Agriculture, Utilities, Chemical.
Source: Ansell product page (Key features, Description, Recommended for, Primary industries as printed). Wording is the manufacturer's, its marketing words dropped.
What you get
One dispenser of 50 gloves: Microflex 93-260 green nitrile exam gloves in the size you pick above. Sold by the dispenser, 50 gloves; the price is for the whole dispenser.
- 93260080 (M): dispenser of 50 gloves, $28.49
- 93260090 (L): dispenser of 50 gloves, $28.49
- 93260100 (XL): dispenser of 50 gloves, $28.49
- 93260110 (2XL): dispenser of 50 gloves, $28.49
Related Ansell part numbers
All the Ansell Microflex nitrile exam gloves we stock are on the Ansell Microflex nitrile exam gloves page (18 listings).
Source: Product names in the manufacturer's words, its marketing words dropped; prices are ours.
Microflex 93-260 questions
Which sizes are on this page? M, L, XL, 2XL; the manufacturer makes it in S (6.5 - 7), M (7.5 - 8), L (8.5 - 9), XL (9.5 - 10), XXL (10.5 - 11), XS (5.5 - 6); pick the size above and the part number changes with it.
How thick is the 93-260? Finger 0.20 mm / 7.9 mil, palm 0.20 mm / 7.9 mil, as the manufacturer prints it (Ansell product page).
What does 0.65 AQL mean? The AQL is the acceptable quality level for pinholes in the manufacturer's inspection (freedom from holes, inspection level I); a lower figure is a tighter sampling limit. Ansell prints 0.65 AQL for the 93-260 (Ansell product page).
Is the 93-260 latex free? Ansell prints "Not made from natural rubber latex: Yes"; allergy prevention: Latex (Type I) (Ansell product page).
Is the 93-260 powder free and textured? Powder-Free, textured fingers surface, as the manufacturer prints it (Ansell product page).
Is the 93-260 food safe or exam grade? Ansell prints: FDA 21 CFR 177.2600-US Food Contact rated (Ansell product page); those are the manufacturer's markings and the standards are not quoted here.
Microflex 93-260 documents
- Ansell product page: MICROFLEX 93-260
- Ansell Product Data Sheet
- Ansell EU Declaration Of Conformity
- Ansell UK Declaration Of Conformity
- Ansell glove selector (ansell.com)
- Ansell at ansell.com
Source: Ansell product page downloads (Product Data Sheet, declarations, instructions for use) as linked there.
MICROFLEX® Chemical-Resistant Disposable Gloves, available in the versions listed below.
- Three layer design for protection against harsh chemicals
- The thinnest chemical resistant disposable glove for tactility and dexterity
- Extra soft material and ergonomic design for fit, feel and flexibility
- Their low AQL (0.65) means minimal pinhole defect risks
- Tested against fentanyl
Available in 4 versions:
Variant item numbers:
Manufacturer part numbers: 93260080, 93260090, 93260100, 93260110.