Portwest FR Coats & Jackets
17 FR coats & jackets from Portwest, listed with what Portwest publishes, and live prices.
Pick a arc rating band, material or hi-vis class; the list below narrows as you choose. Prices are live.

17 garments
Ratings and specifications are as published by each manufacturer. Tap a group to open it.
Portwest17 garments
- Portwest FR25 Bizflame Plus Jacket — Portwest · Arc rating: 13.6 cal/cm2 (HAF 82%) · Material: Bizflame Work: 99% Cotton, 1% Carbon Fiber · Fabric weight: 10 oz · Standards: EN 1149-5; IEC 61482-2 IEC 61482-1-2 Class 1; EN ISO 11612 A1+A2, B1, C1, E2, F1; EN ISO 11611 Class 2 A1+A2; ASTM F1959/F1959M-12 ATPV 13.6 cal/cm2 (HAF 82%)
- Portwest FR41 Sealtex Flame Hi-Vis FR Jacket — Portwest · Material: Sealtex Flame HV: 100% Polyester, PU Coated · Fabric weight: 7.5 oz · Standards: ANSI/ISEA 107 Type R Class 3; ANSI/ISEA 107 Type P Class 3; EN ISO 14116 Index 1; EN 1149-5; EN 13034 Type 6; EN ISO 20471 Class 3; EN 343 Class 3:1 X
- Portwest FR44 FR Jackets, Sealtex Flame Hi-Vis FR Coat 50″ — Portwest · Material: Sealtex Flame HV: 100% Polyester, PU Coated · Fabric weight: 7.5 oz · Standards: ANSI/ISEA 107 Type R Class 3; EN ISO 14116 Index 1; EN 1149-5; EN 13034 Type 6; EN ISO 20471 Class 3; EN 343 Class 3:1 X
- Portwest FR610 Arc Flash Jackets, Bizflame Work Insulated FR Parka — Portwest · Arc rating: 40 cal/cm2 · PPE category: CAT 4 · Material: Bizflame Work: 99% Cotton, 1% Carbon Fiber; Lining: 100% FR Cotton; Filling: 90% Modacrylic, 10% Aramid · Fabric weight: 10 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 40 cal/cm2
- Portwest FR612 FR Jackets, Bizflame X-Back Insulated FR Winter Parka — Portwest · Arc rating: 56 cal/cm2 · PPE category: CAT 4 · Material: Bizflame 88/12: 88% Cotton, 12% Nylon; Lining: 100% FR Polyester with transparent FR PU coating; Lining: 100% FR Cotton quilted to 100% Modacrylic Wadding · Fabric weight: 9 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 56 cal/cm2; CSA Z96 Class 1 Level FR
- Portwest FR68 Bizflame Industry FR Jacket — Portwest · Arc rating: 16 cal/cm2 (HAF 83.7%) · Material: Bizflame Ultra: 80% Cotton, 19% Polyester, 1% Carbon Fiber · Fabric weight: 10 oz · Standards: EN ISO 11612 A1+A2, B1, C1, E2, F1; EN ISO 11611 Class 1 A1+A2; EN 1149-5; IEC 61482-2 IEC 61482-1-2 Class 1; EN 13034 Type PB [6]; ASTM F1959/F1959M-12 ATPV 16 cal/cm2 (HAF 83.7%); IEC 61482-2 IEC 61482-1-2 APC 1
- Portwest FR708 FR Jackets, Bizflame Knit Heavyweight Hooded FR — Portwest · Arc rating: 22 cal/cm2 · PPE category: CAT 2 · Material: Bizflame Knit: 100% Cotton · Fabric weight: 12 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 22 cal/cm2
- Portwest FR726 FR Jackets, Bizflame Knit 1/4 Zipper FR Sweatshirt — Portwest · Arc rating: 24 cal/cm2 · PPE category: CAT 2 · Material: Bizflame Knit: 100% Cotton · Fabric weight: 10 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 24 cal/cm2
- Portwest FR747 FR Jackets, Bizflame Knit 4" X Back FR Hoodie — Portwest · Arc rating: 24 cal/cm2 · PPE category: CAT 2 · Material: Bizflame Knit: 100% Cotton · Fabric weight: 10 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 24 cal/cm2; CSA Z96 Class 1 Level FR
- Portwest FR760 Arc Flash Clothing, Bizflame Knit Hooded Zipper-Front FR — Portwest · Arc rating: 24 cal/cm2 · PPE category: CAT 2 · Material: Bizflame Knit: 100% Cotton · Fabric weight: 10 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 24 cal/cm2
- Portwest IAS3215 Arc Flash Jackets, Avenger 9oz Insulated Parka — Portwest · Arc rating: 61 cal/cm2 · Material: 88% FR Cotton, 12% Nylon; Lining: Westex: 88% FR Cotton, 12% Nylon; Filling: Westex FR Modacrylic Insulation · Fabric weight: 9 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; CGSB 155.20; CSA Z462; CSA Z96 Class 1 Level FR; ASTM F1959 ATPV 61 cal/cm2
- Portwest IOS324 Arc Flash Jackets, Striped Fleece Full Zip Jacket — Portwest · Arc rating: 23 cal/cm2 · PPE category: CAT 2 · Material: Oratex: 55% Modacrylic, 45% Cotton · Fabric weight: 14 oz · Standards: NFPA 2112; NFPA 70E; CSA Z462; ASTM F1506; CGSB 155.20; CSA Z96; ASTM F1959 ATPV 23 cal/cm2
- Portwest IOS375 Arc Flash Jackets, Women's Segmented Striped Navy Fleece Full — Portwest · Arc rating: 23 cal/cm2 · PPE category: CAT 2 · Material: Oratex: 55% Modacrylic, 45% Cotton · Fabric weight: 14 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; CSA Z462; CGSB 155.20; ASTM F1959 ATPV 23 cal/cm2
- Portwest IUS215 Arc Flash Jackets, Ultrasoft 9oz Insulated Parka — Portwest · Arc rating: 61 cal/cm2 · Material: Westex: 88% FR Cotton, 12% Nylon; Lining: Westex: 88% FR Cotton, 12% Nylon; Filling: Westex FR Modacrylic Insulation · Fabric weight: 9 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; CGSB 155.20; CSA Z462; CSA Z96 Class 1 Level FR; ASTM F1959 ATPV 61 cal/cm2
- Portwest IUS515 Arc Flash Jackets, Ultrasoft 9oz Hi-Vis Insulated Parka — Portwest · Arc rating: 61 cal/cm2 · Material: Westex: 88% FR Cotton, 12% Nylon; Filling: Westex: 88% FR Cotton, 12% Nylon · Fabric weight: 9 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; CGSB 155.20; CSA Z462; CSA Z96 Class 2 Level 2; ASTM F1959 ATPV 61 cal/cm2
- Portwest UFR48 Arc Flash Jackets, DuraDuck Flame Quilt Lined FR Jacket — Portwest · Arc rating: 45 cal/cm2 · PPE category: CAT 4 · Material: Bizflame Duck: 100% Cotton Duck; Lining: 100% FR Cotton; Filling: 90% Modacrylic, 10% Aramid · Fabric weight: 10 oz · Standards: NFPA 2112; NFPA 70E; ASTM F1506; ASTM F1959 ATPV 45 cal/cm2
- Portwest UFR81 Arc Flash Clothing, Modaflame Knit Zipper-Front Hooded FR — Portwest · Arc rating: 16 cal/cm2 · Material: Modaflame Knit: 60% Modacrylic, 39% Cotton, 1% Carbon Fiber · Fabric weight: 9 oz · Standards: ASTM F1959 ATPV 16 cal/cm2; EN ISO 11612 A1, B1, C1, F1; EN 1149-5; IEC 61482-2 IEC 61482-1-1 ELIM 9.2 cal/cm2, ATPV 15 cal/cm2; IEC 61482-2 IEC 61482-1-2 APC 1
Do not see what you need? Browse the category or call (925) 215-7337.
In plain words. An arc rating is the amount of heat energy, in calories per square centimetre, that a fabric blocked before the test predicted a second-degree burn; it is printed on the garment label as ATPV or EBT. NFPA 70E groups PPE into categories by the minimum rating: Category 1 needs 4 cal/cm², Category 2 8, Category 3 25, Category 4 40. Flame resistance (the fabric self-extinguishes) is a separate test from the arc rating; a garment can be FR without an arc rating. Every number here is the manufacturer's.
Technical. Arc ratings by ASTM F1959 (reported as ATPV, or EBT where the fabric breaks open first); FR garment performance by ASTM F1506 (electric arc) and NFPA 2112 (flash fire, with NFPA 2113 for selection); NFPA 70E Table 130.7(C)(15)(c) sets the PPE categories by incident energy. Hi-vis FR garments also carry an ANSI/ISEA 107 class. Fabric weights are in ounces per square yard as published.
Ratings and specifications on this page are shown as published by the manufacturer or the named standard and describe performance in that standard's test. They are not a recommendation for any task. The employer's hazard assessment decides what protective equipment a job needs. Verify details against the manufacturer's current documentation before you buy.
The standard at a glance
Copied from the named standard or regulation and shown with its source; nothing in these tables is Bayshore's recommendation.
NFPA 70E PPE categories
| PPE category | Minimum arc rating of the clothing system |
|---|---|
| Category 1 | 4 cal/cm² |
| Category 2 | 8 cal/cm² |
| Category 3 | 25 cal/cm² |
| Category 4 | 40 cal/cm² |
Source: NFPA 70E, Table 130.7(C)(15)(c). Arc ratings (ATPV or EBT) tested to ASTM F1959; FR garments to ASTM F1506 and NFPA 2112.