Portwest FR Head & Face Covers
9 FR head & face covers from Portwest, listed with what Portwest publishes, and live prices.
Pick a arc rating band, material or hi-vis class; the list below narrows as you choose. Prices are live.

9 garments
Ratings and specifications are as published by each manufacturer. Tap a group to open it.
Portwest9 garments
- Portwest CS20 Head & Face Covers, Fleece Balaclava — Portwest
- Portwest CS21 Head & Face Covers, Neck Tube — Portwest
- Portwest CS23 Head & Face Covers, Multiway Balaclava — Portwest
- Portwest FR09 Arc Flash Hoods & Face Shields, Modaflame Knit FR Balaclava — Portwest · Arc rating: 16 cal/cm2 · Material: Modaflame Knit: 60% Modacrylic, 39% Cotton, 1% Carbon Fiber · Fabric weight: 9 oz · Standards: ASTM F1959 ATPV 16 cal/cm2; EN ISO 11612 A1, B1, C1, F1; EN 1149-5
- Portwest FR19 Head & Face Covers, Modaflame Knit FR Neck Tube — Portwest
- Portwest FR40 Head & Face Covers, FR Mask — Portwest
- Portwest FR901 Head & Face Covers, Bizflame Insulated FR Winter Hood — Portwest
- Portwest IKBJ58 Arc Flash Hoods & Face Shields, Kermel Knit Rib Balaclava — Portwest · Arc rating: 33 cal/cm2 · PPE category: CAT 3 · Material: 49.5% Kermel, 49.5% FR Rayon, 1% Carbon Fiber · Fabric weight: 8.5 oz · Standards: NFPA 70E; ASTM F1506; ASTM F1959 ATPV 33 cal/cm2
- Portwest IOP364 Arc Flash Hoods & Face Shields, Fleece Hood — Portwest · Arc rating: 23 cal/cm2 · PPE category: CAT 2 · Material: Oratex: 55% Modacrylic, 45% Cotton · Fabric weight: 14 oz · Standards: NFPA 2112; NFPA 70E; CGSB 155.20; ASTM F1959 ATPV 23 cal/cm2
Do not see what you need? Browse the category or call (925) 215-7337.
In plain words. An arc rating is the amount of heat energy, in calories per square centimetre, that a fabric blocked before the test predicted a second-degree burn; it is printed on the garment label as ATPV or EBT. NFPA 70E groups PPE into categories by the minimum rating: Category 1 needs 4 cal/cm², Category 2 8, Category 3 25, Category 4 40. Flame resistance (the fabric self-extinguishes) is a separate test from the arc rating; a garment can be FR without an arc rating. Every number here is the manufacturer's.
Technical. Arc ratings by ASTM F1959 (reported as ATPV, or EBT where the fabric breaks open first); FR garment performance by ASTM F1506 (electric arc) and NFPA 2112 (flash fire, with NFPA 2113 for selection); NFPA 70E Table 130.7(C)(15)(c) sets the PPE categories by incident energy. Hi-vis FR garments also carry an ANSI/ISEA 107 class. Fabric weights are in ounces per square yard as published.
Ratings and specifications on this page are shown as published by the manufacturer or the named standard and describe performance in that standard's test. They are not a recommendation for any task. The employer's hazard assessment decides what protective equipment a job needs. Verify details against the manufacturer's current documentation before you buy.
The standard at a glance
Copied from the named standard or regulation and shown with its source; nothing in these tables is Bayshore's recommendation.
NFPA 70E PPE categories
| PPE category | Minimum arc rating of the clothing system |
|---|---|
| Category 1 | 4 cal/cm² |
| Category 2 | 8 cal/cm² |
| Category 3 | 25 cal/cm² |
| Category 4 | 40 cal/cm² |
Source: NFPA 70E, Table 130.7(C)(15)(c). Arc ratings (ATPV or EBT) tested to ASTM F1959; FR garments to ASTM F1506 and NFPA 2112.