BW Technologies / Honeywell Analytics Multi-Gas Monitors
61 multi-gas monitors from BW Technologies / Honeywell Analytics, listed with what BW Technologies / Honeywell Analytics publishes, and live prices.
Pick a gas, number of gases, sampling or battery; the list below narrows as you choose. Prices are live.
61 products
Ratings and specifications are as published by each manufacturer. Tap a group to open it.
BW Technologies / Honeywell Analytics61 products
Open the BW Technologies / Honeywell Analytics page
- BW Technologies BWC4-B-N Multi-Gas Detectors, Honeywell BW Clip4 Portable — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Diffusion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; CE; IECEx Ex ia IIC T4 Ga; UL Class I Div 1 Groups A, B, C, D; UL Class I Zone 0 Group IIC
- BW Technologies BWC4-Y-N Multi-Gas Detectors, / Honeywell Analytics BW, 2-Year — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Diffusion
- BW Technologies CP-I-000000M1-Y-00 Multi-Gas Detectors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: CO · Gases: 1 gas · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CP-I-0000H1M1-Y-00 Multi-Gas Detectors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: H2S; CO · Gases: 2 gases · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CP-I-0000H1S3-Y-00 Multi-Gas Detectors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: H2S; SO2 · Gases: 2 gases · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CP-I-00X100S3-Y-00 Multi-Gas Detectors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: O2; SO2 · Gases: 2 gases · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CP-I-00X1H100-Y-00 Multi-Gas Detectors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: O2; H2S · Gases: 2 gases · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CP-I-00X1H1M1-Y-00 Multi-Gas Detectors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: H2S; CO · Gases: 2 gases · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CP-I-00X1H1S3-Y-00 Multi-Gas Detectors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: O2; H2S; SO2 · Gases: 3 gases · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CP-I-W50000M1-Y-00 Multi-Gas Detectors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: LEL; CO · Gases: 2 gases · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CP-I-W50000S3-Y-00 Multi-Gas Detectors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: LEL; SO2 · Gases: 2 gases · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CP-I-W500H100-Y-00 Multi-Gas Detectors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: LEL; H2S · Gases: 2 gases · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CP-I-W500H1M1-Y-00 Multi-Gas Detectors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: LEL; H2S; CO · Gases: 3 gases · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CP-I-W500H1S3-Y-00 Multi-Gas Detectors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: LEL; H2S; SO2 · Gases: 3 gases · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CP-I-W5X10000-Y-00 Multi-Gas Detectors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2 · Gases: 2 gases · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CP-I-W5X100M1-Y-00 Multi-Gas Detectors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; CO · Gases: 3 gases · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CP-I-W5X100S3-Y-00 Multi-Gas Detectors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; SO2 · Gases: 3 gases · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CP-I-W5X1H100-Y-00 Multi-Gas Detectors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S · Gases: 3 gases · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CP-I-W5X1H1M1-Y-00 Multi-Gas Detectors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CP-I-W5X1H1S3-Y-00 Multi-Gas Detectors, Honeywell BW Icon+ — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; SO2 · Gases: 4 gases · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies CPD-W5X1H1M1-Y-00 Multi-Gas Detectors, Honeywell BW, Oxygen — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Diffusion
- BW Technologies CPD-W7X1H1M1-B-00 Multi-Gas Detectors, Honeywell BW, Oxygen — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Diffusion
- BW Technologies HRR-A300009ABK-000 Sample-Draw Gas Monitors, Honeywell BW RigRat — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Approvals: cETLus Class I Div 1 Groups A, B, C, D, T4
- BW Technologies HRR-A300100ABK-000 Sample-Draw Gas Monitors, Honeywell BW RigRat — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Approvals: cETLus Class I Div 1 Groups A, B, C, D, T4
- BW Technologies HRR-B300009ABK-000 Sample-Draw Gas Monitors, Honeywell BW RigRat — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Approvals: cETLus Class I Div 1 Groups A, B, C, D, T4
- BW Technologies HRR-B300100ABK-000 Sample-Draw Gas Monitors, Honeywell BW RigRat — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Approvals: cETLus Class I Div 1 Groups A, B, C, D, T4
- BW Technologies HRR-C301009ABK-000 Sample-Draw Gas Monitors, Honeywell BW RigRat — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Approvals: cETLus Class I Div 1 Groups A, B, C, D, T4
- BW Technologies HRR-C301100ABK-100 Sample-Draw Gas Monitors, Honeywell BW RigRat — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Approvals: cETLus Class I Div 1 Groups A, B, C, D, T4
- BW Technologies HRR-C303100ABK-000 Sample-Draw Gas Monitors, Honeywell BW RigRat — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Approvals: cETLus Class I Div 1 Groups A, B, C, D, T4
- BW Technologies HRR-D301009ABK-000 Sample-Draw Gas Monitors, Honeywell BW RigRat — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Approvals: cETLus Class I Div 1 Groups A, B, C, D, T4
- BW Technologies HRR-G301009ABK-000 Sample-Draw Gas Monitors, Honeywell BW RigRat — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Approvals: cETLus Class I Div 1 Groups A, B, C, D, T4
- BW Technologies HRR-G301100ABK-100 Sample-Draw Gas Monitors, Honeywell BW RigRat — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Approvals: cETLus Class I Div 1 Groups A, B, C, D, T4
- BW Technologies HRR-H301009ABK-000 Sample-Draw Gas Monitors, Honeywell BW RigRat — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Approvals: cETLus Class I Div 1 Groups A, B, C, D, T4
- BW Technologies HRR-H301100ABK-100 Sample-Draw Gas Monitors, Honeywell BW RigRat — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Approvals: cETLus Class I Div 1 Groups A, B, C, D, T4
- BW Technologies HU-X1W100M1A1-Y-N Honeywell BW Ultra Portable Oxygen — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; CO; NH3 · Gases: 4 gases · Sampling: Diffusion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; CE; IECEx Ex ia IIC T4 Ga; UL Class I Div 1 Groups A, B, C, D; UL Class I Zone 0 Group IIC
- BW Technologies HU-X1W1H1M1S1-Y-N Multi-Gas Detectors, Honeywell BW Ultra — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO; SO2 · Gases: 5 gases · Sampling: Diffusion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; CE; IECEx Ex ia IIC T4 Ga; UL Class I Div 1 Groups A, B, C, D; UL Class I Zone 0 Group IIC
- BW Technologies ICON-B-H Multi-Gas Detectors, Honeywell BW Icon Portable, Oxygen — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies ICON-B-S Multi-Gas Detectors, Honeywell BW Icon Portable Hydrogen — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; SO2 · Gases: 4 gases · Sampling: Diffusion · Approvals: ATEX, FCC ID and IC, IECEx
- BW Technologies MCX3-XW00-Y-NA Multi-Gas Detectors, Honeywell BW MicroClip — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2 · Gases: 2 gases · Sampling: Diffusion · Battery: Li-Ion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; CE; CSA Class I Div 1 Groups A, B, C, D; IECEx Ex ia IIC T4 Ga
- BW Technologies MCX3-XW0M-Y-NA Multi-Gas Detectors, Honeywell BW — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; CO · Gases: 3 gases · Sampling: Diffusion · Battery: Li-Ion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; CE; CSA Class I Div 1 Groups A, B, C, D; IECEx Ex ia IIC T4 Ga
- BW Technologies MCX3-XWHM-B-NA Multi-Gas Detectors, Honeywell BW — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Diffusion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; CE; CSA Class I Div 1 Groups A, B, C, D; IECEx Ex ia IIC T4 Ga
- BW Technologies MCX3-XWHM-Y-NA Multi-Gas Detectors, / Honeywell Analytics — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 5 gases · Sampling: Diffusion
- BW Technologies MCXL-00HM-Y-NA Multi-Gas Detectors, Honeywell BW MicroClip XL — BW Technologies / Honeywell Analytics · Gases detected: H2S; CO · Gases: 2 gases · Sampling: Diffusion · Battery: Li-Ion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; CE; CSA Class I Div 1 Groups A, B, C, D; IECEx Ex ia IIC T4 Ga
- BW Technologies MCXL-X000-Y-NA Honeywell BW MicroClip XL Portable Oxygen Multi — BW Technologies / Honeywell Analytics · Gases detected: O2 · Gases: 1 gas · Sampling: Diffusion · Battery: Li-Ion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; CE; CSA Class I Div 1 Groups A, B, C, D; IECEx Ex ia IIC T4 Ga
- BW Technologies MCXL-X00M-Y-NA Honeywell BW MicroClip XL Portable Oxygen — BW Technologies / Honeywell Analytics · Gases detected: O2; CO · Gases: 2 gases · Sampling: Diffusion · Battery: Li-Ion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; CE; CSA Class I Div 1 Groups A, B, C, D; IECEx Ex ia IIC T4 Ga
- BW Technologies MCXL-X0H0-B-NA Honeywell BW MicroClipXL Hydrogen Sulfide — BW Technologies / Honeywell Analytics · Gases detected: O2; H2S · Gases: 2 gases · Sampling: Diffusion · Battery: Li-Ion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; CE; CSA Class I Div 1 Groups A, B, C, D; IECEx Ex ia IIC T4 Ga
- BW Technologies MCXL-X0H0-Y-NA Honeywell BW MicroClipXL Hydrogen Sulfide — BW Technologies / Honeywell Analytics · Gases detected: O2; H2S · Gases: 2 gases · Sampling: Diffusion · Battery: Li-Ion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; CE; CSA Class I Div 1 Groups A, B, C, D; IECEx Ex ia IIC T4 Ga
- BW Technologies MCXL-X0HM-Y-NA Honeywell BW MicroClipXL Hydrogen Sulfide — BW Technologies / Honeywell Analytics · Gases detected: O2; H2S; CO · Gases: 3 gases · Sampling: Diffusion · Battery: Li-Ion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; CE; CSA Class I Div 1 Groups A, B, C, D; IECEx Ex ia IIC T4 Ga
- BW Technologies MCXL-XW00-B-NA Honeywell BW MicroClipXL Combustible Gas — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2 · Gases: 2 gases · Sampling: Diffusion · Battery: Li-Ion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; CE; CSA Class I Div 1 Groups A, B, C, D; IECEx Ex ia IIC T4 Ga
- BW Technologies MCXL-XW00-Y-NA Honeywell BW MicroClip XL Portable Combustible — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2 · Gases: 2 gases · Sampling: Diffusion · Battery: Li-Ion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; CE; CSA Class I Div 1 Groups A, B, C, D; IECEx Ex ia IIC T4 Ga
- BW Technologies MCXL-XW0M-Y-NA Honeywell BW MicroClip XL Portable Combustible — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; CO · Gases: 3 gases · Sampling: Diffusion · Battery: Li-Ion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; CE; CSA Class I Div 1 Groups A, B, C, D; IECEx Ex ia IIC T4 Ga
- BW Technologies MCXL-XWH0-Y-NA Honeywell BW MicroClip XL Portable Oxygen — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S · Gases: 3 gases · Sampling: Diffusion · Battery: Li-Ion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; CE; CSA Class I Div 1 Groups A, B, C, D; IECEx Ex ia IIC T4 Ga
- BW Technologies MCXL-XWHM-B-NA Honeywell BW MicroClip XL Portable Oxygen — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Diffusion · Battery: Li-Ion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; CE; CSA Class I Div 1 Groups A, B, C, D; IECEx Ex ia IIC T4 Ga
- BW Technologies MCXL-XWHM-Y-NA Multi-Gas Detectors, / Honeywell Analytics — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Diffusion
- BW Technologies XT-XUHM-Y-NA Sample-Draw Gas Monitors, Honeywell BW Max XT II — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Approvals: ATEX II 1G Ex ia IIC T4 Ga; BR-Ex ia IIC T4; IECEx Ex ia IIC T4 Ga; UL Class I Div 1 Groups A, B, C, D
- BW Technologies XT-XW00-Y-NA Sample-Draw Gas Monitors, Honeywell BW Max XT II — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2 · Gases: 2 gases · Sampling: Pump (sample draw) · Battery: Li-Ion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; BR-Ex ia IIC T4; IECEx Ex ia IIC T4 Ga; UL Class I Div 1 Groups A, B, C, D
- BW Technologies XT-XW0M-Y-NA Sample-Draw Gas Monitors, Honeywell BW Max XT II — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; CO · Gases: 3 gases · Sampling: Pump (sample draw) · Battery: Li-Ion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; BR-Ex ia IIC T4; IECEx Ex ia IIC T4 Ga; UL Class I Div 1 Groups A, B, C, D
- BW Technologies XT-XWH0-Y-NA Sample-Draw Gas Monitors, Honeywell BW Max XT II — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S · Gases: 3 gases · Sampling: Pump (sample draw) · Battery: Li-Ion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; BR-Ex ia IIC T4; IECEx Ex ia IIC T4 Ga; UL Class I Div 1 Groups A, B, C, D
- BW Technologies XT-XWHM-B-NA Honeywell BW GasAlertMax XT II Portable Combustible — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Diffusion · Battery: Li-Ion · Approvals: ATEX II 1G Ex ia IIC T4 Ga; BR-Ex ia IIC T4; IECEx Ex ia IIC T4 Ga; UL Class I Div 1 Groups A, B, C, D
- BW Technologies XT-XWHM-Y-NA Sample-Draw Gas Monitors, / Honeywell Analytics, Pump — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw)
- BW Technologies XT-XWHM-Y-NA-CS Sample-Draw Gas Monitors, Honeywell BW Max XT II, O2 — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO
Do not see what you need? Browse the category or call (925) 215-7337.
In plain words. A gas monitor is described by the gases it detects (LEL for combustibles, O2 for oxygen, H2S, CO, and so on), how many it detects at once, whether it samples by diffusion (air reaches the sensors on its own) or with a pump (sample draw, for checking a space before entry), how it is powered, and the approvals that let it be used in a classified area. All of these are the manufacturer's published specifications; alarm points and calibration intervals follow the manufacturer's manual.
Technical. Intrinsic-safety approvals are listed as the manufacturer prints them (UL or CSA Class I Division 1 Groups A–D, ATEX and IECEx Ex ia IIC T4 marks). Sensor ranges are quoted per gas (for example 0–100% LEL, 0–30% volume O2, 0–100 ppm H2S, 0–500 ppm CO; PID sensors for VOCs in ppm or ppb with the lamp energy in eV; IR sensors for CO2 or methane). Calibration gas is matched to the monitor's sensors and listed by concentration. Draeger detector tubes have their own finder page.
Ratings and specifications on this page are shown as published by the manufacturer or the named standard and describe performance in that standard's test. They are not a recommendation for any task. The employer's hazard assessment decides what protective equipment a job needs. Verify details against the manufacturer's current documentation before you buy.
The standard at a glance
Copied from the named standard or regulation and shown with its source; nothing in these tables is Bayshore's recommendation.
OSHA confined-space atmosphere limits
| Condition (29 CFR 1910.146) | Limit |
|---|---|
| Oxygen deficient | Below 19.5% oxygen |
| Oxygen enriched | Above 23.5% oxygen |
| Flammable | Above 10% of the lower flammable limit (LFL) |
| Toxic | Above the substance's permissible exposure limit (29 CFR 1910 Subpart Z) |
| Approval mark (as printed by the manufacturer) | Meaning |
|---|---|
| UL or CSA Class I, Division 1, Groups A–D | Intrinsically safe for flammable gas and vapour atmospheres (North America) |
| ATEX / IECEx Ex ia IIC T4 | Intrinsically safe, gas group IIC, temperature class T4 (Europe / international) |
Source: OSHA 29 CFR 1910.146 (permit-required confined spaces). Alarm set points and calibration intervals follow each manufacturer's manual. Draeger detector tubes have their own finder.