MSA Multi-Gas Monitors
29 multi-gas monitors from MSA, listed with what MSA publishes, and live prices.
Pick a gas, number of gases, sampling or battery; the list below narrows as you choose. Prices are live.
29 products
Ratings and specifications are as published by each manufacturer. Tap a group to open it.
MSA29 products
- MSA 1011692 ALTAIR 5X Multi-Gas Monitor Kit, Probe — MSA · Gases detected: LEL; O2; H2S; CO; SO2 · Gases: 5 gases · Sampling: Pump (sample draw) · Approvals: IP65
- MSA 10116924 ALTAIR 5X Multi-Gas Monitor, LEL — MSA · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Approvals: IP65
- MSA 10116925 Sample-Draw Gas Monitors, ALTAIR 5X Combustible Gas, Hydrogen Sulfide — MSA · Gases detected: LEL; O2; H2S; CO; SO2 · Gases: 5 gases · Sampling: Pump (sample draw) · Battery: Rechargeable Li-Ion
- MSA 10116926 ALTAIR 5X Multi-Gas Detector Kit, LEL — MSA · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw)
- MSA 10116928 ALTAIR 5X Multi-Gas Monitor Kit, Probe — MSA · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Approvals: IP65
- MSA 10125912 ALTAIR 4X Portable Oxygen — MSA · Gases detected: LEL; O2; CO · Gases: 3 gases · Sampling: Diffusion
- MSA 10125913 ALTAIR 4X Oxygen, Carbon Monoxide And Methane Multi Gas Monitor — MSA · Gases detected: LEL; O2; CO · Gases: 3 gases · Sampling: Diffusion
- MSA 10125914 ALTAIR 4X Methane And Nitrogen Dioxide Multi Gas Monitor — MSA · Gases detected: LEL; NO2 · Gases: 2 gases · Sampling: Diffusion
- MSA 10153985 ALTAIR 2XT Sulfur Dioxide And Hydrogen Sulfide Multi Gas Monitor — MSA · Gases detected: H2S; SO2 · Gases: 2 gases · Sampling: Diffusion
- MSA 10154040 ALTAIR 2XT Carbon Monoxide, Hydrogen Sulfide — MSA · Gases detected: H2S; CO · Gases: 2 gases · Sampling: Diffusion
- MSA 1016544 ALTAIR 5X Multi-Gas Monitor, LEL — MSA · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw)
- MSA 10178356 Multi-Gas Detectors, ALTAIR 4XR Multi-Gas Monitor Kit, LEL — MSA · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Diffusion · Approvals: IP68; MIL-STD-810G
- MSA 10178357 ALTAIR 4XR Multi-Gas Monitor Kit, Pump Probe — MSA · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Approvals: IP68; MIL-STD-810G
- MSA 10178358 Sample-Draw Gas Monitors, ALTAIR 4XR Combustible Gas, Hydrogen Sulfide — MSA · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw)
- MSA 10178558 ALTAIR 4XR Multi-Gas Detector, Glow in the Dark — MSA · Gases detected: LEL; O2; H2S; CO · Approvals: IP68; MIL-STD-810G
- MSA 10178559 ALTAIR 4XR Portable Oxygen And Combustible Gas Multi Gas Monitor — MSA · Gases detected: LEL; O2 · Gases: 2 gases · Sampling: Diffusion
- MSA 10178566 ALTAIR 4XR Combustible Gas — MSA · Gases detected: LEL; O2; CO · Gases: 3 gases · Sampling: Diffusion
- MSA 10178568 ALTAIR 4XR Portable Combustible Gas And Oxygen Multi Gas Monitor — MSA · Gases detected: LEL; O2 · Gases: 2 gases · Sampling: Diffusion
- MSA 10178571 ALTAIR 4XR Combustible Gas, Oxygen — MSA · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Diffusion
- MSA 10178572 ALTAIR Carbon Monoxide, Combustible Gas — MSA · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Diffusion
- MSA 10245598 ALTAIR io 4 Connected Multi-Gas Detector, LEL — MSA · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Diffusion
- MSA 10255038 Sample-Draw Gas Monitors, ALTAIR io 6 Portable Carbon Monoxide — MSA · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw)
- MSA 10255039 Sample-Draw Gas Monitors, ALTAIR io 6 Portable Combustible Gas — MSA · Gases detected: LEL; O2; H2S; CO; SO2 · Gases: 5 gases · Sampling: Pump (sample draw)
- MSA 10255040 Sample-Draw Gas Monitors, ALTAIR io 6 Portable Combustible Gas — MSA · Gases detected: LEL; O2; H2S; CO; Cl2 · Gases: 5 gases · Sampling: Pump (sample draw)
- MSA 10255041 Sample-Draw Gas Monitors, ALTAIR io 6 Portable Combustible Gas — MSA · Gases detected: LEL; O2; H2S; CO; NH3 · Gases: 5 gases · Sampling: Pump (sample draw)
- MSA 10255042 Sample-Draw Gas Monitors, ALTAIR io 6 Portable Combustible Gas — MSA · Gases detected: LEL; O2; H2S; CO; NO2 · Gases: 5 gases · Sampling: Pump (sample draw)
- MSA A-ALT5X-ALK0100C010 Sample-Draw Gas Monitors, ALTAIR 5X Portable Combustible Gas — MSA · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw)
- MSA A-ALT5XALKD100C000 Multi-Gas Detectors, ALTAIR 5X Multi-Gas Monitor, LEL — MSA · Gases detected: LEL; O2; H2S; CO; Ammonia (NH3) · Gases: 5 gases · Sampling: Pump (sample draw)
- MSA H2412-1312 Bacharach PCA Carbon Monoxide, Oxygen — MSA · Gases detected: O2; CO; NO2; NO · Gases: 4 gases · Sampling: Diffusion
Do not see what you need? Browse the category or call (925) 215-7337.
In plain words. A gas monitor is described by the gases it detects (LEL for combustibles, O2 for oxygen, H2S, CO, and so on), how many it detects at once, whether it samples by diffusion (air reaches the sensors on its own) or with a pump (sample draw, for checking a space before entry), how it is powered, and the approvals that let it be used in a classified area. All of these are the manufacturer's published specifications; alarm points and calibration intervals follow the manufacturer's manual.
Technical. Intrinsic-safety approvals are listed as the manufacturer prints them (UL or CSA Class I Division 1 Groups A–D, ATEX and IECEx Ex ia IIC T4 marks). Sensor ranges are quoted per gas (for example 0–100% LEL, 0–30% volume O2, 0–100 ppm H2S, 0–500 ppm CO; PID sensors for VOCs in ppm or ppb with the lamp energy in eV; IR sensors for CO2 or methane). Calibration gas is matched to the monitor's sensors and listed by concentration. Draeger detector tubes have their own finder page.
Ratings and specifications on this page are shown as published by the manufacturer or the named standard and describe performance in that standard's test. They are not a recommendation for any task. The employer's hazard assessment decides what protective equipment a job needs. Verify details against the manufacturer's current documentation before you buy.
The standard at a glance
Copied from the named standard or regulation and shown with its source; nothing in these tables is Bayshore's recommendation.
OSHA confined-space atmosphere limits
| Condition (29 CFR 1910.146) | Limit |
|---|---|
| Oxygen deficient | Below 19.5% oxygen |
| Oxygen enriched | Above 23.5% oxygen |
| Flammable | Above 10% of the lower flammable limit (LFL) |
| Toxic | Above the substance's permissible exposure limit (29 CFR 1910 Subpart Z) |
| Approval mark (as printed by the manufacturer) | Meaning |
|---|---|
| UL or CSA Class I, Division 1, Groups A–D | Intrinsically safe for flammable gas and vapour atmospheres (North America) |
| ATEX / IECEx Ex ia IIC T4 | Intrinsically safe, gas group IIC, temperature class T4 (Europe / international) |
Source: OSHA 29 CFR 1910.146 (permit-required confined spaces). Alarm set points and calibration intervals follow each manufacturer's manual. Draeger detector tubes have their own finder.