Breathing Air Testing
14 breathing air testing from every brand we carry, listed with what each manufacturer publishes.
Pick a brand, gas, number of gases, sampling or battery; the list below narrows as you choose.

14 products
Ratings and specifications are as published by each manufacturer. Tap a group to open it.
Draeger14 products
- Draeger 6525587 Aerotest Plug-In Nipple, G 1/8 Male — Draeger
- Draeger 6525588 Aerotest Closing Coupling, G 1/4 Male — Draeger
- Draeger 6525913 Aerotest Barbed Nipple Connection — Draeger
- Draeger 6525932 Aerotest Alpha Measuring Unit Block — Draeger · Gases detected: Breathing air contaminants
- Draeger 6527151 Aerotest O2 Pressure Reducer, Adjustable 20/7 bar — Draeger
- Draeger 6527157 OxyTest Carrying Case, Empty — Draeger
- Draeger 6527325 Aerotest Measuring Unit, PN 3 bar — Draeger · Gases detected: H2S; CO; CO2; Oil
- Draeger 8103557 Aerotest Oil Impactor Adapter — Draeger · Gases detected: Oil mist
- Draeger Aerotest Alpha Low-Pressure Breathing Air Test Kit — Draeger · Approvals: DIN EN 12021
- Draeger Aerotest Oil Impactor, Pack of 10 — Draeger · Gases detected: Oil mist
- Draeger Aerotest Simultan HP Breathing Air Test Kit — Draeger · Gases detected: CO; CO2; Oil; Water vapor
- Draeger Aerotest SimultanTest CO2 Purity Test Kit — Draeger · Gases detected: Impurities in carbon dioxide
- Draeger CH07000 Aerotest Spare Tube Holder — Draeger
- Draeger MultiTest med. Int. Medical Gas Test Kit — Draeger · Gases detected: H2S; CO; CO2; SO2; Nitrous fumes; Oil; Water vapor
Do not see what you need? Browse the category or call (925) 215-7337.
A gas monitor is described by the gases it detects (LEL for combustibles, O2 for oxygen, H2S, CO, and so on), how many it detects at once, whether it samples by diffusion (air reaches the sensors on its own) or with a pump (sample draw, for checking a space before entry), how it is powered, and the approvals that let it be used in a classified area. All of these are the manufacturer's published specifications; alarm points and calibration intervals follow the manufacturer's manual.
Technical. Intrinsic-safety approvals are listed as the manufacturer prints them (UL or CSA Class I Division 1 Groups A–D, ATEX and IECEx Ex ia IIC T4 marks). Sensor ranges are quoted per gas (for example 0–100% LEL, 0–30% volume O2, 0–100 ppm H2S, 0–500 ppm CO; PID sensors for VOCs in ppm or ppb with the lamp energy in eV; IR sensors for CO2 or methane). Calibration gas is matched to the monitor's sensors and listed by concentration. Draeger detector tubes have their own selector page.
The ratings, test results and standards shown here are the manufacturers' published values, reproduced as published. Nothing on this page is a recommendation by Bayshore Safety that any product is suitable for a particular task, hazard or workplace. Selecting safety products and protective equipment is the responsibility of the end user and the employer, based on their own hazard assessment and the regulations that apply to their work. Confirm every value on the manufacturer's own documentation before use.
The standard at a glance
Copied from the named standard or regulation and shown with its source; nothing in these tables is Bayshore's recommendation.
OSHA confined-space atmosphere limits
| Condition (29 CFR 1910.146) | Limit |
|---|---|
| Oxygen deficient | Below 19.5% oxygen |
| Oxygen enriched | Above 23.5% oxygen |
| Flammable | Above 10% of the lower flammable limit (LFL) |
| Toxic | Above the substance's permissible exposure limit (29 CFR 1910 Subpart Z) |
| Approval mark (as printed by the manufacturer) | Meaning |
|---|---|
| UL or CSA Class I, Division 1, Groups A–D | Intrinsically safe for flammable gas and vapour atmospheres (North America) |
| ATEX / IECEx Ex ia IIC T4 | Intrinsically safe, gas group IIC, temperature class T4 (Europe / international) |
Source: OSHA 29 CFR 1910.146 (permit-required confined spaces). Alarm set points and calibration intervals follow each manufacturer's manual. Draeger detector tubes have their own selector.