Description
Duracell MN2400B4Z Coppertop Battery AAA: AAA alkaline batteries; zinc-manganese dioxide alkaline (Zn/MnO2); nominal voltage 1.5 V; designation ANSI 24AP / IEC LR03; operating temperature -20°C to 54°C (-4°F to 130°F); typical weight 13 g (0.4 oz) a cell. Storage life as the manufacturer prints it: Guaranteed 12 Years in Storage
. The manufacturer prints Built in the USA With US & Global Parts
. The manufacturer describes it: Duracell Coppertop AA and AAA alkaline batteries, built in the USA with US and global parts, contain Power Boost Ingredients, in the manufacturer's words. Sold by the pack of 4 batteries; the price is for the whole pack. That is $3.50 a battery at the price shown. Country of origin: USA. Ships in 1–2 business days; most orders arrive in 3–7 business days. All the Duracell Coppertop alkaline batteries we stock are on the Duracell Coppertop alkaline batteries page.
Duracell MN2400B4Z specifications
From the Product Technical Data Sheet
| Specification | Detail |
|---|---|
| Data sheet | MN24USCT0122 |
| Chemistry | Zn/MnO2 |
| Battery type | Alkaline-Manganese Dioxide Battery |
| Size | AAA |
| Nominal voltage | 1.5 V |
| Impedance | 128 m-ohm @ 1 kHz |
| Typical weight | 13 g (0.4 oz) |
| Typical volume | 3.5 cm3 (0.5 in3) |
| Terminals | Flat |
| Storage temperature range | 6°C to 29°C (42°F to 85°F) |
| Operating temperature range | -20°C to 54°C (-4°F to 130°F) |
| ANSI designation | 24AP |
Source: the manufacturer's Product Technical Data Sheet MN24USCT0122 (PDF), read Nov 22 2026; the sheet's figures. Delivered capacity depends on the load, the temperature and the cut-off voltage, as the sheet says.
From the manufacturer's product page
| Specification | Detail |
|---|---|
| Product | Coppertop Battery AAA |
| Part number | MN2400B4Z |
| Pack sizes the manufacturer lists | 2-pack, 4-pack, 6-pack, 8-pack, 10-pack, 12-pack, 16-pack, 20-pack, 24-pack |
| Storage life | Guaranteed 12 Years in Storage |
| Where built | Built in the USA With US & Global Parts |
| Specifications | Duracell Coppertop AA and AAA alkaline batteries are made for everyday devices such as toys, baby devices, home and kitchen accessories, flashlights, medical devices, clocks, and more. |
| Uses the manufacturer lists | Toys Remote controls Flashlights Baby devices Kitchen accessories Calculators Clocks and Radios Portable Electronics Wireless Mice and Keyboards |
Source: the manufacturer's product page (MN2400), read Nov 22 2026; wording is the manufacturer's, its marketing words dropped.
From the Article Information Sheet
| Specification | Detail |
|---|---|
| Document | Duracell Alkaline Batteries (Major and Specialty Cells), Article Information Sheet AIS-ALK, issue date 1-May-15, last revision 1/1/2026 |
| Description | Duracell branded consumer alkaline battery |
| Product category | Electro-technical device |
| Use | Portable power source for electronic devices |
| Cells the sheet covers | Major Cells: AA (LR6), AAA (LR03), C (LR14), D (LR20) & 9V (6LR61, 6LP3146); Specialty Cells: AAAA (LR8D425), MN11, MN21 (8LR932, A23, 23A), MN27, PX76/A76/76A (LR44), PX625, (LR9), 186 (LR43), 191/LR1130 (LR54), N (LR1), J (4LR61), 4.5V, 625A |
| Ingredients (alkaline cell) | Zinc (CAS 7440-66-6) 10-25%; Manganese Dioxide (CAS 1313-12-9) 35-40%; Nickel Compounds 0-6%; Alkali Metal Hydroxide (Potassium Hydroxide, CAS 1310-58-3) 5-10%; Nickel-plated Steel can 8-15%; Other Non-Reactive Materials 10-15% |
| Handling precautions | Avoid mechanical and electrical abuse. Do not short circuit or install incorrectly. Batteries may rupture or vent if disassembled, crushed, recharged or exposed to high temperatures. Install batteries in accordance with equipment instructions. |
| Storage precautions | Store batteries in a dry place at normal room temperature. Refrigeration does not make them last longer. |
| First aid if swallowed | Do not induce vomiting. Seek medical attention immediately. For information on treatment, call the National Battery Ingestion Hotline (telephone numbers for the USA and Canada are provided below). |
| Battery ingestion hotline | USA/Canada Calls Only: 1-800-498-8666 (Toll Free) (24-Hour National Battery Ingestion Hotline) |
| Fire hazard | Batteries may rupture or leak if involved in a fire. Use any extinguishing media appropriate for the surrounding area. |
| Fires involving large quantities | Large quantities of batteries involved in a fire will rupture and release caustic potassium hydroxide. Firefighters should wear self-contained breathing apparatus and protective clothing. |
| Collection and disposal | Dispose of used (or excess) batteries in compliance with federal, state/provincial and local regulations. Do not accumulate large quantities of used batteries for disposal as accumulations could cause batteries to short-circuit. Do not incinerate. In regions/states that require recycling, dispose within the collection network. |
| RCRA line (40 CFR 261) | Classified as non-hazardous waste (not ignitable, corrosive, reactive or toxic). Federal Universal Waste Regulations (40 CFR 273) do not apply. State requirements may be more stringent than Federal. |
| Transport status | Alkaline batteries (sometimes referred to as "Dry Cell" or "household" batteries) are not listed or regulated as dangerous goods under IATA Dangerous Goods Regulations, ICAO Technical Instructions, IMDG Code, UN Model Regulations, U.S. Hazardous Materials Regulations (49 CFR), and UNECE ADR. |
| US DOT line | US DOT SP 49 CFR 172.102 Special Provision 130 |
| Air transport line | Special Provision A123 NOTE: The words "NOT RESTRICTED" and "SPECIAL PROVISION A123" must be included on the description of the substance on the Air Waybill, when air way-bill is issued. |
| Mercury | During the manufacturing process, no mercury is added. |
| California Proposition 65 | No warning required per 3rd party assessment. |
| Battery standards the sheet lists | ANSI C18.1M Part 1, ANSI C18.1M Part 2, ANSI C18.4M, IEC 60086-1, IEC 60086-2, IEC 60086-5 |
Source: the manufacturer's Article Information Sheet (PDF), its Safety Data Sheet form for batteries, read Nov 22 2026; the sheet's words.
Product details
| Specification | Detail |
|---|---|
| Part number | MN2400B4Z |
| Pack | 4-pack (card of 4) |
| UPC | 00413330406150 |
| Country of origin | USA |
| Sold by | Pack of 4 |
| Hazardous material for shipping | No |
Source: the manufacturer's product record.
Battery safety and the rules
The manufacturer publishes an Article Information Sheet for its alkaline batteries in place of a Safety Data Sheet, and says why: Articles, such as batteries, are exempt from GHS SDS classification criteria. The GHS criteria is not designed or intended to be used to classify the physical, health and environmental hazards of an article. Branded consumer batteries are defined as electro-technical devices. The design, safety, manufacture, and qualification of branded consumer batteries follow ANSI and IEC battery standards.
The sheet (Duracell Alkaline Batteries (Major and Specialty Cells), Article Information Sheet AIS-ALK, issue date 1-May-15, last revision 1/1/2026) prints: Avoid mechanical and electrical abuse. Do not short circuit or install incorrectly. Batteries may rupture or vent if disassembled, crushed, recharged or exposed to high temperatures. Install batteries in accordance with equipment instructions.
; Store batteries in a dry place at normal room temperature. Refrigeration does not make them last longer.
; Do not induce vomiting. Seek medical attention immediately. For information on treatment, call the National Battery Ingestion Hotline (telephone numbers for the USA and Canada are provided below).
; Batteries may rupture or leak if involved in a fire. Use any extinguishing media appropriate for the surrounding area.
; Large quantities of batteries involved in a fire will rupture and release caustic potassium hydroxide. Firefighters should wear self-contained breathing apparatus and protective clothing.
; Dispose of used (or excess) batteries in compliance with federal, state/provincial and local regulations. Do not accumulate large quantities of used batteries for disposal as accumulations could cause batteries to short-circuit. Do not incinerate. In regions/states that require recycling, dispose within the collection network.
; Alkaline batteries (sometimes referred to as "Dry Cell" or "household" batteries) are not listed or regulated as dangerous goods under IATA Dangerous Goods Regulations, ICAO Technical Instructions, IMDG Code, UN Model Regulations, U.S. Hazardous Materials Regulations (49 CFR), and UNECE ADR.
. Those are the manufacturer's statements; the rule paragraphs are quoted here so the employer reads the rule itself.
29 CFR 1910.1200(c) Definitions: Article means a manufactured item other than a fluid or particle: (i) Which is formed to a specific shape or design during manufacture; (ii) Which has end use function(s) dependent in whole or in part upon its shape or design during end use; and (iii) Which under normal conditions of use does not release more than very small quantities, e.g., minute or trace amounts of a hazardous chemical (as determined under paragraph (d) of this section), and does not pose a physical hazard or health risk to employees.
29 CFR 1910.1200(b)(6) Scope and application: this section does not apply to: ... (v) Articles (as that term is defined in paragraph (c) of this section).
29 CFR 1910.1200(b)(1) Hazard communication, scope and application: this section requires chemical manufacturers or importers to classify the hazards of chemicals which they produce or import, and all employers to provide information to their employees about the hazardous chemicals to which they are exposed, by means of a hazard communication program, labels and other forms of warning, safety data sheets, and information and training.
The manufacturer prints the designations, standards and figures in the tables above (IEC 60086-5, ANSI C18.1M, Part-2) and no other standard, rating or approval for this AAA alkaline batteries; nothing beyond the manufacturer's printed figures is claimed here. Where batteries are stored, installed and collected for disposal, which of the manufacturer's handling and disposal lines apply and which state recycling rules apply at the job site is the employer's call under 1910.1200 and the hazard assessment of 1910.132(d). We sell nationwide.
Source: OSHA 29 CFR 1910.1200 as published on ecfr.gov (1910.1200); the manufacturer's Article Information Sheet (PDF) and data sheets index; read Nov 22 2026.
Duracell MN2400B4Z, as Duracell describes it
Product name on the manufacturer's page: Coppertop Battery AAA; pack sizes it lists: 2-pack, 4-pack, 6-pack, 8-pack, 10-pack, 12-pack, 16-pack, 20-pack, 24-pack.
In the manufacturer's words: Guaranteed 12 Years in Storage
; Built in the USA With US & Global Parts
.
As the manufacturer prints it:
- Duracell Coppertop AA and AAA alkaline batteries, built in the USA with US and global parts, contain Power Boost Ingredients, in the manufacturer's words
- Duracell Coppertop AA and AAA alkaline batteries are made for everyday devices such as toys, baby devices, home and kitchen accessories, flashlights, medical devices, clocks, and more
Devices the page lists: Toys Remote controls Flashlights Baby devices Kitchen accessories Calculators Clocks and Radios Portable Electronics Wireless Mice and Keyboards.
About the manufacturer: Duracell Inc. of Bethel, Connecticut (a Berkshire Hathaway company, as its data sheets print) makes the Coppertop, Optimum, lithium and rechargeable lines; its US battery operations are in LaGrange, Georgia, as its Article Information Sheets print. Procell is the Duracell company's professional business-to-business battery brand, in the manufacturer's words.
Source: the manufacturer's product page (MN2400); wording is the manufacturer's, its marketing words dropped.
What you get
One pack of 4 (Duracell MN2400B4Z): one retail card of 4 Coppertop AAA alkaline batteries (MN2400B4Z). Sold by the pack of 4 batteries; the price is for the whole pack. That is $3.50 a battery at the price shown. Nothing else is in the box.
Related Duracell part numbers
All the Duracell Coppertop alkaline batteries we stock are on the Duracell Coppertop alkaline batteries page (5 listings).
Source: Product names in the manufacturer's words; the items listed beside this one are the other packs on this page, the same product group and the other Duracell listings we stock; prices are ours.
Duracell MN2400B4Z questions
What does the data sheet print for the Duracell MN2400B4Z cell? Alkaline-Manganese Dioxide Battery, nominal voltage 1.5 V, impedance 128 m-ohm @ 1 kHz, typical weight 13 g (0.4 oz), operating temperature range -20°C to 54°C (-4°F to 130°F) (sheet MN24USCT0122).
What size designation does the Duracell MN2400B4Z cell carry? ANSI 24AP and IEC LR03, as the manufacturer prints it.
How long does the manufacturer say the Duracell MN2400B4Z AAA alkaline batteries keep in storage? 12 years, as the storage-life line quoted in the table above puts it. The sheet says to store them in a dry place at normal room temperature.
Are the Duracell MN2400B4Z AAA alkaline batteries regulated for shipping? No. The manufacturer's Article Information Sheet says alkaline batteries are not listed or regulated as dangerous goods under IATA, ICAO, IMDG, the UN Model Regulations, 49 CFR or ADR, and cites US DOT Special Provision 130; we sell nationwide.
How are the Duracell MN2400B4Z AAA alkaline batteries sold? Sold by the pack of 4 batteries; the price is for the whole pack. That is $3.50 a battery at the price shown.
Where are the Duracell MN2400B4Z AAA alkaline batteries made? The product record gives the country of origin as USA; the manufacturer's page prints "Built in the USA With US & Global Parts".
Duracell MN2400B4Z documents
- Duracell product page: Coppertop Battery AAA
- Duracell Product Technical Data Sheet MN24USCT0122 (PDF)
- Duracell Article Information Sheet: Duracell Alkaline Batteries (Major and Specialty Cells) (PDF)
- Duracell Product Technical Data Sheets library
- Duracell Battery Cross Reference Chart
- Duracell battery care, use and disposal page
- Duracell product group page: Coppertop alkaline batteries
- OSHA 29 CFR 1910.1200 (eCFR)
Source: Duracell product pages and the documents its Technical Library links; eCFR where a rule is quoted.
Manufacturer part number: MN2400B4Z (Coppertop Battery AAA).