Description
The North 140038 is the irritant smoke fit test tubes. Sold by the case. Ships in 1–2 business days; most orders arrive in 3–7 business days.
PIP catalog data for 140038
| Item | Manufacturer data |
|---|---|
| Part number | 140038 |
| Color | Black |
| Case pack | 6 ea |
| Country of origin | United States |
| UPC | 797402005497 |
| PIP stock status | Stock |
Source: PIP Rich Product Data, October 2026.
Fit testing and the OSHA standard
29 CFR 1910.134(f) requires a fit test before first use of a tight-fitting respirator, whenever a different facepiece is used, and at least annually; it allows the qualitative (QLFT) and quantitative (QNFT) protocols in Appendix A, which include the Bitrex (denatonium benzoate) and irritant smoke qualitative protocols. The 770046 irritant smoke tubes and the 140090 kit are for the irritant smoke protocol; the 193170 kit and the 193171/193172 solutions are for the Bitrex protocol; 770021 is the quantitative fit test adapter for the 5400, 5500, 7600 and 7700 Series.
Source: 29 CFR 1910.134(f) and Appendix A; North fit test kit literature; PIP Rich Product Data, October 2026.
Replacement irritant smoke tubes for qualitative respirator fit testing.
Manufacturer item number: 140038.
Sold by the case
One case holds 6 pieces (the manufacturer's minimum order). The price shown is for the full case; quantity 1 = 1 case (6 pieces).
North 140038 questions
How is the 140038 packed? Case pack 6 ea (PIP data).
Guides: what OSHA requires for fit testing · qualitative vs quantitative fit testing · all North and Draeger respirators by model and hazard.