MSA Advantage 4000 Single-Port Full Facepiece
The MSA Advantage 4000 Single-Port Full Facepiece: sizes Small, Medium, Large; . Below: every version with a live price, the cartridges and filters MSA lists for it, the parts and accessories, the NIOSH approvals from the Certified Equipment List and the OSHA assigned protection factors. Ships in 1–2 business days; most orders arrive in 3–7 business days.
Advantage 4000 Single-Port Full Facepiece
Source: MSA One Mask. Countless Possibilities. Introducing the new Advantage 4000 Facepiece, ID 0130-01-MC / June 2012; MSA's Advantage 4000 Facepiece data sheet, ID 1012-19-MC / Jan 2008.
OptimAir TL PAPR (with the RD40 adapter per MSA)
Source: MSA OptimAir TL Powered Air-Purifying Respirator data sheet, 1010-15-MC / 04.2025.
Parts, adapters and accessories
Source: MSA data sheets and parts lists named in the research.
Advantage 4000 Single-Port Full Facepiece data
| Item | Manufacturer data |
|---|---|
| Facepiece type | full |
| Sizes | Small, Medium, Large |
| Part numbers by size | with Nosecup, Push-To-Connect Adapter: 10075914: Small, Silicone, Net Head Harness; 10075915: Small, Hycar, Net Head Harness; 10075910: Small, Silicone, Rubber Head Harness; 10075911: Small, Hycar, Rubber Head Harness; 10075908: Medium, Silicone, Net Head Harness; 10075909: Medium, Hycar, Net Head Harness; 10075904: Medium, Silicone, Rubber Head Harness; 10075905: Medium, Hycar, Rubber Head Harness; 10075920: Large, Silicone, Net Head Harness; 10075921: Large, Hycar, Net Head Harness; 10075916: Large, Silicone, Rubber Head Harness; 10075917: Large, Hycar, Rubber Head Harness; with Nosecup, No Adapter: 10083796: Small, Silicone, Net Head Harness; 10083797: Small, Hycar, Net Head Harness; 10083798: Small, Silicone, Rubber Head Harness; 10083799: Small, Hycar, Rubber Head Harness; 10083792: Medium, Silicone, Net Head Harness; 10083793: Medium, Hycar, Net Head Harness; 10083794: Medium, Silicone, Rubber Head Harness; 10083795: Medium, Hycar, Rubber Head Harness; 10083800: Large, Silicone, Net Head Harness; 10083801: Large, Hycar, Net Head Harness; 10083802: Large, Silicone, Rubber Head Harness; 10083803: Large, Hycar, Rubber Head Harness |
| Materials | two facepiece elastomers; black silicone or Hycar rubber |
| Harness | two head harness styles; adjustable silicone rubber four-point or polyester net four-point harness |
| Nose cup | a standard nose cup with twin inhalation check valves, available in small and medium/large sizes |
| NIOSH approval | NIOSH; approval_matrices "ADVANTAGE 4000 SERIES APR RESPIRATOR" (Material 10084702 Rev 6) for APR configurations; gas mask family insert 817241 for chin-type canister configurations |
| Standards | Advantage 4000 Single-Port and Twin-Port Facepieces meet all applicable requirements of ANSI Z87.1 2003 Occupational and Educational Personal Eye and Face Protection Devices. |
Source: MSA One Mask. Countless Possibilities. Introducing the new Advantage 4000 Facepiece, ID 0130-01-MC / June 2012; MSA's Advantage 4000 Facepiece data sheet, ID 1012-19-MC / Jan 2008.
NIOSH approvals naming the Advantage 4000 Single-Port Full Facepiece
The NIOSH Certified Equipment List carries 118 current MSA approvals whose product line names the Advantage 4000 Single-Port Full Facepiece: 4 CBRN / gas mask (TC-14G), 1 supplied-air (TC-19C), 2 powered air-purifying (TC-21C), 21 chemical cartridge (TC-23C), 90 air-purifying particulate (TC-84A). The first 15:
| Approval | Product line | For protection against | Facepiece |
|---|---|---|---|
| TC-14G-0274 | Advantage 3100 & 4100 / UltraVue / UltraElite /Millennium facepieces, canister p/n 10059903, and accessories | Ammonia, Chlorine, P100, Phosphine | Full Facepiece |
| TC-14G-0279 | UltraVue / UltraElite / Millennium / Advantage 3100 & 4100 Facepieces with 10067469 canister | Organic Vapor, P100 | Full Facepiece |
| TC-14G-0280 | Ultravue / UltraElite / Clearvue / Advantage 3100 & 4100 / Millennium Facepieces with 10067491 canister | Chlorine, Hydrogen Fluoride, P100 | Full Facepiece |
| TC-14G-0282 | Ultravue, Ultra Elite, Clearvue, Advantage 3100 & 4100, Millennium facepieces with 10067470 canister | Chlorine, Chlorine Dioxide, Formaldehyde, Hydrogen Sulfide, P100, Sulfur Dioxide | Full Facepiece |
| TC-19C-0438 | Abrasi-Blast Advantage 4000, Continuous Flow, Type CE, Supplied Air Respirator | Abrasive Blasting | Full Facepiece |
| TC-21C-0763 | OptimAir MM2k PAPR w/ Models 4100 and 3100 full facepieces and Type HE filter | HEPA (PAPR only) | Full Facepiece |
| TC-21C-0805 | OptimAir TL PAPR with UltraElite and Advantage 3100 & 4100 Full Facepieces | HEPA (PAPR only) | Full Facepiece |
| TC-23C-2314 | Advantage 4000 Series Full Facepiece Respirator | Organic Vapor | Full Facepiece |
| TC-23C-2315 | Advantage 4000 Series Full Facepiece Respirator | Chlorine, Chlorine Dioxide, Hydrogen Chloride, Hydrogen Sulfide, Sulfur Dioxide | Full Facepiece |
| TC-23C-2316 | Advantage 4000 Series Full Facepiece Respirator | Chlorine, Chlorine Dioxide, Hydrogen Chloride, Hydrogen Sulfide, Organic Vapor, Sulfur Dio | Full Facepiece |
| TC-23C-2317 | Advantage 4000 Series Full Facepiece Respirator | Ammonia, Methylamine | Full Facepiece |
| TC-23C-2318 | Advantage 4000 Series Full Facepiece Respirator | Chlorine, Mercury Vapor | Full Facepiece |
| TC-23C-2319 | Advantage 4000 Series Full Facepiece Respirator | Ammonia, Chlorine, Chlorine Dioxide, Formaldehyde, Hydrogen Chloride, Hydrogen Fluoride, H | Full Facepiece |
| TC-23C-2331 | Advantage 4000-4200 Series, Duo-Twin, Combination AP, Type C, CF Supplied Air Respirator | Organic Vapor | Full Facepiece |
| TC-23C-2332 | Advantage 4000-4200 Series Duo-Twin Combination AP, Type C, CF, Supplied Air Respirator | Chlorine, Chlorine Dioxide, Hydrogen Chloride, Hydrogen Sulfide, Sulfur Dioxide | Full Facepiece |
Source: NIOSH Certified Equipment List, manufacturer MSA, read November 4 2026.
Assigned protection factor
| Respirator type (OSHA Table 1) | APF |
|---|---|
| Air-purifying full facepiece | 50 |
| Powered air-purifying full facepiece | 1,000 |
| Supplied-air respirator, continuous flow, full facepiece | 1,000 |
Source: OSHA 29 CFR 1910.134 Table 1 (Assigned Protection Factors). The APF applies only when the respirator is used in a program that meets the standard, including fit testing of tight-fitting facepieces (29 CFR 1910.134(f)) and a cartridge change schedule (29 CFR 1910.134(d)(3)(iii)).
Guides: MSA Advantage cartridge codes · Advantage 420 vs 900 vs 3200 · what is a PAPR.
MSA Advantage 4000 Single-Port Full Facepiece questions
What is the Advantage 4000 single-port facepiece? A full facepiece with one inlet that takes an adapter: 10065328 twin-cartridge (approved with the full range of Advantage cartridges), 10065329 push-to-connect (AirHawk SCBA, PremAire supplied air) or 10065330 RD40 thread (OptimAir TL and MM2K PAPR, chin-type gas masks, constant-flow air-line) (MSA Advantage 4000 facepiece sheet).
Which listings on this site mix the 4000 and 4200? Two listings carry both: the single-port no-adapter facepieces (10083796/92/00 silicone; 10083797/93/01 hycar) alongside the 4200 twin-port facepieces (10083784/60/88; 10083785/81/89). The single-port takes adapters; the twin-port has bayonet mounts in the lens (MSA data sheets). 10083801 is the single-port hycar large sold alone.
What materials and harnesses are there? Black silicone or Hycar rubber facepiece; adjustable silicone rubber four-point or polyester net four-point harness; nose cup with twin inhalation check valves (MSA data sheet).
What is the NIOSH approval? Per configuration on the Advantage 4000 Series approval insert (Material 10084702 Rev 06); with the twin-cartridge adapter the Advantage cartridge inserts list the 4000 (for example TC-23C-2314 for the GMA with 10065328).
The ratings, test results and standards shown here are the manufacturers' published values, reproduced as published. Nothing on this page is a recommendation by Bayshore Safety that any product is suitable for a particular task, hazard or workplace. Selecting safety products and protective equipment is the responsibility of the end user and the employer, based on their own hazard assessment and the regulations that apply to their work. Confirm every value on the manufacturer's own documentation before use.