Description
The MSA Advantage 4200 Twin-Port Facepiece is a full facepiece with Advantage bayonet mounts in the lens (twin-port). Our part numbers: 10083785 (Small, polyester net head harness, hycar), 10083781 (Medium, polyester net head harness, hycar), 10083789 (Large, polyester net head harness, hycar), 10083797 (Single Port · S), 10083793 (Single Port · M). Facepieces are available in silicone and Hycar Rubber. Sizes Small, Medium, Large. Ships in 1–2 business days; most orders arrive in 3–7 business days. Advantage 4200 Twin-Port: every cartridge, filter, part and NIOSH approval on one page.
MSA Advantage 4200 Twin-Port Facepiece specifications
| Item | Manufacturer data |
|---|---|
| Facepiece type | Full facepiece |
| Sizes | Small, Medium, Large |
| Our part numbers | 10083785 (Small, polyester net head harness, hycar), 10083781 (Medium, polyester net head harness, hycar), 10083789 (Large, polyester net head harness, hycar), 10083797 (Single Port · S), 10083793 (Single Port · M) |
| Other versions MSA lists | 10083787 (Small, rubber head harness, hycar), 10083783 (Medium, rubber head harness, hycar), 10083791 (Large, rubber head harness, hycar), 10108570 (Small, Kevlar net head harness, hycar), 10108568 (Medium, Kevlar net head harness, hycar), 10108572 (Large, Kevlar net head harness, hycar), 10083784 (Small, polyester net head harness, silicone), 10083760 (Medium, polyester net head harness, silicone), 10083788 (Large, polyester net head harness, silicone), 10083786 (Small, rubber head harness, silicone), 10083782 (Medium, rubber head harness, silicone), 10083790 (Large, rubber head harness, silicone), 10108569 (Small, Kevlar net head harness, silicone), 10108567 (Medium, Kevlar net head harness, silicone), 10108571 (Large, Kevlar net head harness, silicone) |
| Materials | Facepieces are available in silicone and Hycar Rubber |
| Cartridge connection | Twin-Port (Advantage bayonet; MSA Respirator Cartridge Chart 1000-86-MC (Feb 2017): cartridges fit 4000 Series Full-Facepiece) |
| MSA statement | The Advantage 4200 Twin-Port Facepiece is a dedicated twin-cartridge respirator. |
| MSA statement | Facepieces are available in silicone and Hycar Rubber |
| MSA statement | Choice of rubber or net harnesses and three standard sizes for perfect fit |
| MSA statement | Nosecup is standard for reduced fogging in low-temperature or high-moisture environments |
Source: MSA Advantage Twin Cartridge Respirators data sheet 1012-42-MC (08.2025).
Cartridges and filters for the Advantage 4200 Twin-Port Facepiece
MSA Advantage bayonet: Cartridges fit 200 LS and 420 Half-Mask, 1000, 3000 and 4000 Series Full-Facepiece Advantage Respirators.
| Part number | MSA chart description | NIOSH classes | Color coding | MSA pack |
|---|---|---|---|---|
| 815355 | Organic Vapor (GMA) | Organic Vapor | Black | 2/PKG |
| 815362 | Organic Vapor/P100 (GMA) | Organic Vapor, P100 | Black/Magenta | 2/PKG |
| 815357 | Organic Vapor/Acid Gas (GMC) | Organic Vapor, Chlorine, Sulfur Dioxide, Chlorine Dioxide, Hydrogen Chloride, Hydrogen Sulfide | Yellow | 2/PKG |
| 815364 | Organic Vapor/Acid Gas/P100 (GMC) | Organic Vapor, Chlorine, Sulfur Dioxide, Chlorine Dioxide, Hydrogen Chloride, Hydrogen Sulfide, P100 | Yellow/Magenta | 2/PKG |
| 815359 | Multigas (GME) | Organic Vapor, Chlorine, Sulfur Dioxide, Chlorine Dioxide, Hydrogen Chloride, Hydrogen Sulfide, Ammonia, Methylamine, Formaldehyde, Hydrogen Fluoride | Olive | 2/PKG |
| 815366 | Multigas/P100 (GME) | Organic Vapor, Chlorine, Sulfur Dioxide, Chlorine Dioxide, Hydrogen Chloride, Hydrogen Sulfide, Ammonia, Methylamine, Formaldehyde, Hydrogen Fluoride, P100 | Olive/Magenta | 2/PKG |
| 815368 | Chlorine/Mercury Vapor/P100 (Mersorb) | Chlorine, Mercury Vapor, P100 | Olive and black diagonal stripe/Magenta | 2/PKG |
| 815369 | Low-Profile P100 | P100 | Magenta | Pack of 2 |
| 818342 | Flexi-Filter/P100 | P100 | Magenta | — |
| 818343 | Flexi-Filter/P100 w/Nuisance Level OV, Ozone Removal | P100 | Magenta | — |
| 818346 | Flexi-Filter/N95 | N95 | Black | — |
| 815394 | N95 Snap-On Prefilter | N95 | — | Pack of 10 |
| 815392 | Reusable Snap-On Cover (for N95 Snap-On Prefilter) | N95 | — | 2 in a Package |
Source: MSA Respirator Cartridge Chart 1000-86-MC (Feb 2017) (Advantage Respirator Cartridges and Flexi-Filter Pads tables).
NIOSH approval configurations for the Advantage 4200 Twin-Port Facepiece
The MSA NIOSH approval insert for this family lists 56 approval configurations; the first 16:
| Approval | Protection | Cartridge, filter or canister in the configuration |
|---|---|---|
| TC-23C-2314 | OV | 815355 |
| TC-23C-2315 | CL/HC/SD/CD/HS | 815356 |
| TC-23C-2316 | OV/CL/HC/SD/CD/HS | 815357 |
| TC-23C-2317 | AM/MA | 815358 |
| TC-23C-2318 | MV/CL | 815361 |
| TC-23C-2319 | OV/CL/HC/SD/AM/MA/CD/HS/FM/HF | 815359 |
| TC-23C-2525 | OV | 464031 |
| TC-23C-2526 | CL/HC/SD/CD/HS | 464032 |
| TC-23C-2527 | AM/MA | 464033 |
| TC-23C-2534 | OV/CL/HC/SD/CD/HS | 464046 |
| TC-23C-2858 | OV/CL/HC/SD/AM/MA/CD/HS/FM/HF | 492790 |
| TC-84A-4439 | P100 | 815369 |
| TC-84A-4440 | N95/OV | 815355, 815394, 815392 |
| TC-84A-4441 | R95/OV | 815355, 815397, 815401 |
| TC-84A-4442 | P100/OV | 815362 |
| TC-84A-4443 | P100/CL/HC/SD/CD/HS | 815363 |
Source: MSA NIOSH approval insert Advantage-4000-Series (material 10084702 Rev 6). The insert states the respirator is approved only in the listed configurations.
NIOSH approvals naming the Advantage 4200
The NIOSH Certified Equipment List carries 109 current MSA (Mine Safety Appliances Company / MSA Innovation, LLC) approvals whose product line names it: 1 supplied-air (TC-19C), 20 chemical cartridge (TC-23C), 88 air-purifying particulate (TC-84A). The first 12:
| Approval | Product line | For protection against | Facepiece |
|---|---|---|---|
| TC-19C-0438 | Abrasi-Blast Advantage 4000, Continuous Flow, Type CE, Supplied Air Respirator | Abrasive Blasting | Full Facepiece |
| TC-23C-2314 | Advantage 4000 Series Full Facepiece Respirator | Organic Vapor | Full Facepiece |
| TC-23C-2315 | Advantage 4000 Series Full Facepiece Respirator | Chlorine, Chlorine Dioxide, Hydrogen Chloride, Hydrogen Sulfide, Sulfur Dioxide | Full Facepiece |
| TC-23C-2316 | Advantage 4000 Series Full Facepiece Respirator | Chlorine, Chlorine Dioxide, Hydrogen Chloride, Hydrogen Sulfide, Organic Vapor, Sulfur Dioxide | Full Facepiece |
| TC-23C-2317 | Advantage 4000 Series Full Facepiece Respirator | Ammonia, Methylamine | Full Facepiece |
| TC-23C-2318 | Advantage 4000 Series Full Facepiece Respirator | Chlorine, Mercury Vapor | Full Facepiece |
| TC-23C-2319 | Advantage 4000 Series Full Facepiece Respirator | Ammonia, Chlorine, Chlorine Dioxide, Formaldehyde, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Methylamine, Organic Vapor … | Full Facepiece |
| TC-23C-2331 | Advantage 4000-4200 Series, Duo-Twin, Combination AP, Type C, CF Supplied Air Respirator | Organic Vapor | Full Facepiece |
| TC-23C-2332 | Advantage 4000-4200 Series Duo-Twin Combination AP, Type C, CF, Supplied Air Respirator | Chlorine, Chlorine Dioxide, Hydrogen Chloride, Hydrogen Sulfide, Sulfur Dioxide | Full Facepiece |
| TC-23C-2333 | Advantage 4000-4200 Series Duo-Twin Combination AP, Type C, CF, Supplied Air Respirator | Chlorine, Chlorine Dioxide, Hydrogen Chloride, Hydrogen Sulfide, Organic Vapor, Sulfur Dioxide | Full Facepiece |
| TC-23C-2334 | Advantage 4000-4200 Series Duo-Twin Combination AP, Type C, CF, Supplied Air Respirator | Ammonia, Methylamine | Full Facepiece |
| TC-23C-2335 | Advantage 4000-4200 Series Duo-Twin Combination AP, Type C, CF, Supplied Air Respirator | Chlorine, Mercury Vapor | Full Facepiece |
Source: NIOSH Certified Equipment List (November 2026), manufacturer MSA (Mine Safety Appliances Company / MSA Innovation, LLC).
Assigned protection factor
| Respirator type (OSHA Table 1) | APF |
|---|---|
| Air-purifying full facepiece | 50 |
| Supplied-air respirator, continuous flow, full facepiece | 1000 |
Source: OSHA 29 CFR 1910.134 Table 1 (Assigned Protection Factors). The APF applies only when the respirator is used in a program that meets the standard, including fit testing of tight-fitting facepieces (29 CFR 1910.134(f)) and a cartridge change schedule (29 CFR 1910.134(d)(3)(iii)).
Catalog data
| Item | Manufacturer data |
|---|---|
| Material | Hycar |
| Style | Full Face |
Source: Manufacturer published product data as carried in our catalog.
A Hycar full facepiece that works with push-to-connect, RD40 and twin cartridge adapters, so one mask covers air-purifying, supplied air and PAPR setups. It comes in single and twin port versions and three sizes.
- Works with push-to-connect, RD40 and twin cartridge interfaces
- Fog-reducing nose cup
- Hycar facepiece with head harness
- Single port or twin port
- Sizes S, M and L
MSA Advantage 4200 questions
What cartridges fit the MSA Advantage 4200? MSA Advantage bayonet: Cartridges fit 200 LS and 420 Half-Mask, 1000, 3000 and 4000 Series Full-Facepiece Advantage Respirators.
What sizes does the Advantage 4200 come in? Small, Medium, Large: 10083785 (Small, polyester net head harness, hycar), 10083781 (Medium, polyester net head harness, hycar), 10083789 (Large, polyester net head harness, hycar), 10083797 (Single Port · S), 10083793 (Single Port · M).
What is the Advantage 4200 made of? Facepieces are available in silicone and Hycar Rubber.
What is the assigned protection factor of a full facepiece? OSHA Table 1 assigns an APF of 50 to an air-purifying full facepiece.
Guides: half mask vs full facepiece · assigned protection factors · what OSHA requires for fit testing · cleaning and storing respirators · cartridge change schedules · P100 vs N95 vs R95 · all respirators by model and hazard.