MSA Batteries & Chargers
22 batteries & chargers from MSA, listed with what MSA publishes.
Pick a gas, number of gases, sampling or battery; the list below narrows as you choose.

22 products
Ratings and specifications are as published by each manufacturer. Tap a group to open it.
MSA22 products
- MSA 10049059 Power Adapter, for ALTAIR — MSA
- MSA 10074132 Battery - CR2, for ALTAIR Pro — MSA
- MSA 10086639 Charger, for ALTAIR — MSA
- MSA 10087913 Power Adapter, for ALTAIR 4X — MSA
- MSA 10092233 Charger, for ALTAIR — MSA
- MSA 10092936 Power supply, for ALTAIR — MSA
- MSA 10093053 Cradle Only, for ALTAIR — MSA
- MSA 10093054 Charging Cradle, for ALTAIR — MSA
- MSA 10095774 Charger, for ALTAIR — MSA
- MSA 10099397 Charger, for ALTAIR 5X — MSA
- MSA 10110183 9 XCell adapter socket, for ALTAIR 5X — MSA
- MSA 10114835 Battery or Charger, for ALTAIR 5X — MSA
- MSA 10114837 Battery, for ALTAIR 5X — MSA
- MSA 10114839 Battery or Charger, for ALTAIR 5X — MSA
- MSA 10124286 Power Supply, for GALAXY GX2 — MSA
- MSA 10127422 Charger, for ALTAIR — MSA
- MSA 10127427 Charger, for ALTAIR — MSA
- MSA 10155203-SP Altair 2X Battery For Altair 2X — MSA
- MSA 10161803 Multi Unit Charger For Altair 5X/4X Multi-Gas — MSA
- MSA 10242927 Charger, for ALTAIR io 4 — MSA
- MSA 10250799 Battery, for ALTAIR io 6 — MSA
- MSA 10253408 Charger, for ALTAIR — MSA
Do not see what you need? Browse the category or call (925) 215-7337.
A gas monitor is described by the gases it detects (LEL for combustibles, O2 for oxygen, H2S, CO, and so on), how many it detects at once, whether it samples by diffusion (air reaches the sensors on its own) or with a pump (sample draw, for checking a space before entry), how it is powered, and the approvals that let it be used in a classified area. All of these are the manufacturer's published specifications; alarm points and calibration intervals follow the manufacturer's manual.
Technical. Intrinsic-safety approvals are listed as the manufacturer prints them (UL or CSA Class I Division 1 Groups A–D, ATEX and IECEx Ex ia IIC T4 marks). Sensor ranges are quoted per gas (for example 0–100% LEL, 0–30% volume O2, 0–100 ppm H2S, 0–500 ppm CO; PID sensors for VOCs in ppm or ppb with the lamp energy in eV; IR sensors for CO2 or methane). Calibration gas is matched to the monitor's sensors and listed by concentration. Draeger detector tubes have their own selector page.
The ratings, test results and standards shown here are the manufacturers' published values, reproduced as published. Nothing on this page is a recommendation by Bayshore Safety that any product is suitable for a particular task, hazard or workplace. Selecting safety products and protective equipment is the responsibility of the end user and the employer, based on their own hazard assessment and the regulations that apply to their work. Confirm every value on the manufacturer's own documentation before use.
The standard at a glance
Copied from the named standard or regulation and shown with its source; nothing in these tables is Bayshore's recommendation.
OSHA confined-space atmosphere limits
| Condition (29 CFR 1910.146) | Limit |
|---|---|
| Oxygen deficient | Below 19.5% oxygen |
| Oxygen enriched | Above 23.5% oxygen |
| Flammable | Above 10% of the lower flammable limit (LFL) |
| Toxic | Above the substance's permissible exposure limit (29 CFR 1910 Subpart Z) |
| Approval mark (as printed by the manufacturer) | Meaning |
|---|---|
| UL or CSA Class I, Division 1, Groups A–D | Intrinsically safe for flammable gas and vapour atmospheres (North America) |
| ATEX / IECEx Ex ia IIC T4 | Intrinsically safe, gas group IIC, temperature class T4 (Europe / international) |
Source: OSHA 29 CFR 1910.146 (permit-required confined spaces). Alarm set points and calibration intervals follow each manufacturer's manual. Draeger detector tubes have their own selector.