Bayshore Safety & Industrial Supplies Guide
Duct, cloth, gaffer, foil, electrical and filament tape: what each is made of and rated for? Duct tape grades by mil and cloth count, gaffer vs duct, UL 181 foil tape for HVAC, aluminum vs lead foil, electrical tape and the UL 510 listing, vinyl colors and phasing, rubber splicing and friction tape, filament and strapping tape tensile strength, packaging tape grades, and the temperature and adhesive facts the makers print
Tapes are named for their backing, and the backing decides what the tape does. Duct tape is a polyethylene-coated cloth scrim with a rubber adhesive, sold by thickness (6 to 7 mil utility, 9 to 10 mil contractor, 11 to 17 mil professional and the heavy-duty grades) and cloth count (threads per inch, 20 to 70; more threads tear cleaner and hold more); it sticks hard and fast to most dry surfaces, tears by hand, fails in heat (adhesive softens above about 140 to 200 °F) and UV, and leaves residue, and despite the name it is not rated for ducts. Gaffer tape is a matte cloth tape with a synthetic rubber adhesive that removes cleanly and does not reflect, the stage, film and event tape. Foil tapes are aluminum (2 to 5 mil) with acrylic adhesive that stays bonded from minus 40 to 300 °F and does not dry out; the HVAC duct sealing tape is the one with the UL 181A-P or 181B-FX listing printed on it (the listing codes require it for sealing rigid and flexible duct), and lead foil tape is for radiation shielding and masking in plating. Electrical tape is PVC (7 mil, flame-retardant, stretchy, 600 volt rated, UL 510 listed, from 0 to 220 °F on premium grades like 3M Super 33+ and 88 and narrower on economy grades), used for insulating splices (as the final layer) and in colors for phase identification (NEC 200.6 and 210.5 require neutral white or gray and ground green; the makers’ convention for phases is black, red, blue on 208/120 and brown, orange, yellow on 480/277); rubber splicing tape (self-fusing EPR or silicone, 30 mil) builds the insulation on splices and terminations before the vinyl, and friction tape (cloth, non-adhesive rubber) is the old mechanical protection layer. Filament tape is polypropylene reinforced with glass fiber strands, rated by tensile strength (100 to 600 lb per inch width) for bundling, palletizing, and holding appliance doors in shipping, and strapping tape is the same family; packaging tape is polypropylene or PVC film with acrylic or hot-melt adhesive in 1.6 to 3.1 mil, rated by thickness and adhesive for carton sealing (hot-melt holds on recycled board, acrylic for cold storage and long term). Double-sided, masking and VHB tapes are in their own guides. The band lists the duct, gaffer, foil, electrical, splicing, filament, strapping and packaging tapes we stock with the thickness, listing and rating the maker prints.
Why duct tape is the wrong tape for a duct. The rubber adhesive on cloth duct tape dries, cracks and lets go in the heat of a plenum within a season, which is why the mechanical codes require a UL 181 listed foil or mastic on duct joints. Every tape is a backing, an adhesive and a rating, and the name is a hint, not a specification. The cards take the tapes by family and say what the maker prints on each.
Tapes, family by family
Thickness, temperature and strength figures are the makers’; listings are UL and the NEC.
In plain words
- Duct tape: cloth and rubber, by mil and thread count; sticks fast, dies in heat and sun, not for ducts.
- Gaffer: matte cloth, removes clean, for cables and floors.
- Foil: acrylic adhesive, minus 40 to 300 °F; UL 181A or 181B printed on it is the only duct tape.
- Electrical: 7 mil vinyl, 600 volt, UL 510; premium grades work at 0 to 220 °F; colors mark phases, white neutral, green ground.
- Rubber splicing tape builds the insulation; vinyl jackets it; friction tape is the old outer wrap.
- Filament tape by pounds per inch; packaging tape by mil and hot-melt or acrylic.
Questions people ask
Can you use duct tape on HVAC ducts?
Not as a code-approved closure; the mechanical codes require tape or mastic listed to UL 181A or 181B, which is printed on foil tapes made for ducts.
What is the difference between gaffer tape and duct tape?
Gaffer tape is matte cloth with a clean-removing adhesive for cables and floors; duct tape is shiny poly-coated cloth with an aggressive rubber adhesive that leaves residue.
What does UL 510 mean on electrical tape?
The UL standard for insulating tape; listed vinyl tape is flame-retardant and rated 600 volts.
What do electrical tape colors mean?
White or gray neutral and green ground are code; black, red, blue (208/120) and brown, orange, yellow (480/277) are the common phase convention, with orange required for a high leg.
What is rubber splicing tape for?
Building the insulation on a splice or termination; it fuses to itself, and vinyl tape goes over it as the jacket.
What tensile strength filament tape do I need?
The makers list 100 lb per inch for light bundling, 200 to 300 for general, and 380 to 600 for pallet unitizing and heavy loads.
Related guides
Masking and painter’s tapeColors, temperature and clean removalVHB and double-sided tapesBonding tapesExtension cord gauge, length and amperageThe cords electrical tape is not a repair forElectrical panel labelingMarking conductors and panelsContractor bags, drum liners, stretch wrap, duct tape and packing tapeThe roofing crew’s consumablesCable ties: tensile strength and UV ratingBundling without tapeThe ratings, test results and standards shown here are the manufacturers' published values, reproduced as published. Nothing on this page is a recommendation by Bayshore Safety that any product is suitable for a particular task, hazard or workplace. Selecting safety products and protective equipment is the responsibility of the end user and the employer, based on their own hazard assessment and the regulations that apply to their work. Confirm every value on the manufacturer's own documentation before use.
© 2026 Bayshore Safety & Industrial Supplies, Inc. All rights reserved. This guide may not be copied or republished without written permission.