Guide · Adhesives, sealants and tapes · Duct, cloth, gaffer, foil, electrical, filament and packaging tape: construction, ratings and listings

Bayshore Safety & Industrial Supplies Guide

Duct, cloth, gaffer, foil, electrical and filament tape: what each is made of and rated for? Duct tape grades by mil and cloth count, gaffer vs duct, UL 181 foil tape for HVAC, aluminum vs lead foil, electrical tape and the UL 510 listing, vinyl colors and phasing, rubber splicing and friction tape, filament and strapping tape tensile strength, packaging tape grades, and the temperature and adhesive facts the makers print

Tapes are named for their backing, and the backing decides what the tape does. Duct tape is a polyethylene-coated cloth scrim with a rubber adhesive, sold by thickness (6 to 7 mil utility, 9 to 10 mil contractor, 11 to 17 mil professional and the heavy-duty grades) and cloth count (threads per inch, 20 to 70; more threads tear cleaner and hold more); it sticks hard and fast to most dry surfaces, tears by hand, fails in heat (adhesive softens above about 140 to 200 °F) and UV, and leaves residue, and despite the name it is not rated for ducts. Gaffer tape is a matte cloth tape with a synthetic rubber adhesive that removes cleanly and does not reflect, the stage, film and event tape. Foil tapes are aluminum (2 to 5 mil) with acrylic adhesive that stays bonded from minus 40 to 300 °F and does not dry out; the HVAC duct sealing tape is the one with the UL 181A-P or 181B-FX listing printed on it (the listing codes require it for sealing rigid and flexible duct), and lead foil tape is for radiation shielding and masking in plating. Electrical tape is PVC (7 mil, flame-retardant, stretchy, 600 volt rated, UL 510 listed, from 0 to 220 °F on premium grades like 3M Super 33+ and 88 and narrower on economy grades), used for insulating splices (as the final layer) and in colors for phase identification (NEC 200.6 and 210.5 require neutral white or gray and ground green; the makers’ convention for phases is black, red, blue on 208/120 and brown, orange, yellow on 480/277); rubber splicing tape (self-fusing EPR or silicone, 30 mil) builds the insulation on splices and terminations before the vinyl, and friction tape (cloth, non-adhesive rubber) is the old mechanical protection layer. Filament tape is polypropylene reinforced with glass fiber strands, rated by tensile strength (100 to 600 lb per inch width) for bundling, palletizing, and holding appliance doors in shipping, and strapping tape is the same family; packaging tape is polypropylene or PVC film with acrylic or hot-melt adhesive in 1.6 to 3.1 mil, rated by thickness and adhesive for carton sealing (hot-melt holds on recycled board, acrylic for cold storage and long term). Double-sided, masking and VHB tapes are in their own guides. The band lists the duct, gaffer, foil, electrical, splicing, filament, strapping and packaging tapes we stock with the thickness, listing and rating the maker prints.

Bayshore Safety. Industrial safety and PPE supplier since 2017. · Current as of November 2026 · UL 510 (insulating tape) and UL 181A and 181B (closure systems for air ducts); NFPA 70 (NEC) 200.6, 210.5 and 250.119 (conductor identification), summarized; ASTM D1000 (test methods for pressure-sensitive adhesive tapes; summarized); the 3M, Shurtape, Nashua, Polyken, Gorilla and Scotch product data on this site (backing, thickness, adhesive, temperature range, tensile strength and listings as printed) and the 3M and Shurtape tape selection guides

Why duct tape is the wrong tape for a duct. The rubber adhesive on cloth duct tape dries, cracks and lets go in the heat of a plenum within a season, which is why the mechanical codes require a UL 181 listed foil or mastic on duct joints. Every tape is a backing, an adhesive and a rating, and the name is a hint, not a specification. The cards take the tapes by family and say what the maker prints on each.

Tapes, family by family

Thickness, temperature and strength figures are the makers’; listings are UL and the NEC.

Duct tape: what do mil and cloth count mean?Thickness in mils (thousandths of an inch) of the whole tape: 6 to 7 mil economy and utility, 8 to 10 mil contractor grade (the general jobsite tape), 11 to 13 mil professional, 14 to 17 mil heavy duty and the extra-strong brands. Cloth count is the threads per square inch in the scrim (a 20 by 10 utility weave to a 70 by 30 premium); higher count tears straighter, resists ripping and holds more. The rubber adhesive is aggressive on dry metal, wood, plastic and board, weak on dusty, oily, wet or rough masonry surfaces, softens above about 140 to 200 °F depending on grade, and leaves residue after sun or heat; the makers rate it for temporary repairs, bundling, sealing poly sheeting and holding, not for ducts, electrical, permanent outdoor or hot surfaces. Colors and printed and camouflage versions are the same tape; silver is the polyethylene coating color.
Gaffer tape vs duct tapeGaffer (gaff) tape: a heavy cotton cloth backing with a matte finish and a synthetic rubber adhesive formulated to remove cleanly without residue for days or weeks; it does not reflect light, tears by hand, holds cables and cords to floors and gear in place, and costs more. Duct tape is shiny, residue-leaving and not clean-removing. Gaffer tape is the tape for cable runs across a floor at an event, marking stage positions and taping down mats; its lower adhesive and clean removal are the point.
Foil tape and the UL 181 listingAluminum foil tapes (2, 3 and 5 mil foil, with or without a scrim, acrylic or rubber adhesive on a liner): the acrylic adhesive stays bonded from about minus 40 to 300 °F and does not dry out, which is why foil tape is the duct and insulation tape. The HVAC rule: the mechanical codes and SMACNA require duct closures listed to UL 181A (rigid fiberglass duct board: 181A-P pressure-sensitive tape, 181A-M mastic, 181A-H heat-activated) or UL 181B (flexible duct: 181B-FX tape, 181B-M mastic), and the listing is printed on the tape with the manufacturer every few inches; an unlisted foil tape is not an acceptable duct closure. Other foil tapes: foil-scrim-kraft (FSK) for insulation facing seams, high-temperature foil to 600 °F for ovens and exhaust, lead foil tape for radiation shielding, plating masking and sound damping (handled with the lead precautions), and copper foil tape for EMI shielding and stained glass.
Electrical tape: vinyl grades, UL 510 and the temperature rangePVC (vinyl) electrical tape is 7 mil, stretches to conform, is flame-retardant, is rated 600 volts, and carries the UL 510 listing (and CSA) for insulating tape; the grades differ in temperature range and cold flexibility: premium (3M Super 33+, Super 88 at 8.5 mil) is rated for use from 0 to 220 °F and applies down to 0 °F; general grade (3M Temflex 1700, 1500) applies above 32 °F and is rated to about 176 °F; economy tapes are narrower still. It is the outer layer over a splice, a marking and phasing tape, and a harness wrap; it is applied stretched (about 75 percent of its stretch) with half-lap overlap and the last wrap laid without tension so it does not flag (unwind). It is not the primary insulation on a high-voltage splice, and it is not duct tape: the adhesive is for the vinyl, not for holding weight.
Phase colors, neutral and groundThe NEC requires the grounded (neutral) conductor identified white or gray (200.6), the equipment grounding conductor green or green with yellow stripe or bare (250.119), and, where a building has more than one voltage system, the ungrounded conductors of each system identified by phase and system at every point where they are accessible (210.5(C)), by color or other means posted at the panel. The common convention (not in the code): black, red, blue for phases A, B, C on 208Y/120 volt systems; brown, orange, yellow on 480Y/277 volt systems; orange for the high leg on a 240/120 delta (which the code does require, 110.15); white or gray neutral; green ground. Colored vinyl tape (3M 35 and Temflex 1500 colors) is how larger conductors are phase-marked at terminations, since conductors over 6 AWG are allowed to be re-identified with tape. The colors are printed on the roll; the tape is the same vinyl.
Rubber splicing tape and friction tapeRubber splicing tape (3M Scotch 23 EPR, 130C linerless, Scotch 70 silicone): a 30 mil self-fusing (self-amalgamating) rubber that is stretched and wrapped to build up the insulation on a splice or termination to the conductor’s insulation thickness and fuses to itself into a solid void-free layer; rated to 69 kV for 23 and 130C and high temperature for silicone 70; it has no adhesive in the usual sense, which is why the vinyl tape goes over it as the jacket. Friction tape: cotton cloth with a tacky rubber compound on both sides, the older mechanical protection layer over rubber tape and the handle grip tape; it is not an insulating tape by itself. Mastic tapes and pads seal connectors and irregular shapes against moisture.
Filament, strapping and packaging tapeFilament tape: a polypropylene or polyester film backing reinforced with continuous glass fiber yarns, with a synthetic rubber adhesive, rated by tensile strength per inch of width (100 lb for light bundling, 200 to 300 lb general, 380 to 600 lb for heavy pallet unitizing and the 3M 893 and 898 class), by thickness (4 to 7 mil) and by whether it leaves residue (the clean-removal grades for appliance doors in shipping); it does not stretch and does not tear by hand. Strapping tape is the same family without glass (tensilized polypropylene, MOPP) in the lighter ranges. Packaging (carton sealing) tape: polypropylene film 1.6 mil (economy) to 2.0 to 3.1 mil (heavy duty), with hot-melt adhesive (fast tack, holds on recycled and dusty corrugated, the general carton tape) or acrylic adhesive (clear, UV stable, works in cold storage and for long-term storage, lower initial tack); PVC packaging tape is quieter and conforms; water-activated (gummed) paper tape bonds into the board for security and recycling. Width 2 and 3 inches; the dispenser guide in the tape category covers hand and machine rolls.
What do all tapes have in common?Three things the makers print: the backing and its thickness, the adhesive type (natural rubber: high initial tack, low heat and UV life; synthetic rubber: better aging; acrylic: lower initial tack, best heat, UV and long-term life; silicone: for silicone surfaces and high heat), and the temperature range (application temperature, the lowest at which the adhesive will wet out, and service temperature). Surfaces are clean, dry and above the application temperature; pressure (a roller or a thumb) is what makes a pressure-sensitive adhesive bond; adhesion builds over 24 to 72 hours; and tapes are stored at room temperature out of sun because the adhesive ages on the roll (shelf life 12 to 24 months). ASTM D1000 is the test method family behind the adhesion, tensile and elongation figures on the data sheet.

In plain words

  • Duct tape: cloth and rubber, by mil and thread count; sticks fast, dies in heat and sun, not for ducts.
  • Gaffer: matte cloth, removes clean, for cables and floors.
  • Foil: acrylic adhesive, minus 40 to 300 °F; UL 181A or 181B printed on it is the only duct tape.
  • Electrical: 7 mil vinyl, 600 volt, UL 510; premium grades work at 0 to 220 °F; colors mark phases, white neutral, green ground.
  • Rubber splicing tape builds the insulation; vinyl jackets it; friction tape is the old outer wrap.
  • Filament tape by pounds per inch; packaging tape by mil and hot-melt or acrylic.

Questions people ask

Can you use duct tape on HVAC ducts?

Not as a code-approved closure; the mechanical codes require tape or mastic listed to UL 181A or 181B, which is printed on foil tapes made for ducts.

What is the difference between gaffer tape and duct tape?

Gaffer tape is matte cloth with a clean-removing adhesive for cables and floors; duct tape is shiny poly-coated cloth with an aggressive rubber adhesive that leaves residue.

What does UL 510 mean on electrical tape?

The UL standard for insulating tape; listed vinyl tape is flame-retardant and rated 600 volts.

What do electrical tape colors mean?

White or gray neutral and green ground are code; black, red, blue (208/120) and brown, orange, yellow (480/277) are the common phase convention, with orange required for a high leg.

What is rubber splicing tape for?

Building the insulation on a splice or termination; it fuses to itself, and vinyl tape goes over it as the jacket.

What tensile strength filament tape do I need?

The makers list 100 lb per inch for light bundling, 200 to 300 for general, and 380 to 600 for pallet unitizing and heavy loads.

The ratings, test results and standards shown here are the manufacturers' published values, reproduced as published. Nothing on this page is a recommendation by Bayshore Safety that any product is suitable for a particular task, hazard or workplace. Selecting safety products and protective equipment is the responsibility of the end user and the employer, based on their own hazard assessment and the regulations that apply to their work. Confirm every value on the manufacturer's own documentation before use.

Stocking a maintenance crib or a production line with adhesives and tape?Call (925) 215-7337 or email us the part numbers, the sizes and the quantities and we will quote by the case with the part numbers listed. We sell nationwide.
All adhesives, sealants and tapes guides

© 2026 Bayshore Safety & Industrial Supplies, Inc. All rights reserved. This guide may not be copied or republished without written permission.

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337