Skip to main content
Gas Monitors by Gas · 1,291 products, every brand we carry

BW Technologies / Honeywell Analytics Multi-Gas Monitors

41 multi-gas monitors from BW Technologies / Honeywell Analytics, listed with what BW Technologies / Honeywell Analytics publishes.

Pick a gas, number of gases, sampling or battery; the list below narrows as you choose.

41 products

Ratings and specifications are as published by each manufacturer. Tap a group to open it.

BW Technologies / Honeywell Analytics41 products

Open the BW Technologies / Honeywell Analytics page

  • BW Technologies BWC4-B-N Clip4 4-Gas Monitor, LEL/O2/H2S/CO, Black — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Diffusion · Battery: Yes · Sensor ranges: LEL 0-100%LEL; O2 0-25%vol; H2S 0-100ppm; CO 0-1000ppm · Approvals: ATEX: II 1G Ex ia IIC T4 Ga; CE European Conformity
  • BW Technologies BWC4-Y-N Clip4 4-Gas Monitor, LEL/O2/H2S/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Diffusion · Battery: Yes · Sensor ranges: LEL 0-100%LEL; O2 0-25%vol; H2S 0-100ppm; CO 0-1000ppm · Approvals: ATEX: II 1G Ex ia IIC T4 Ga; CE European Conformity
  • BW Technologies CPD-W5X1H1M1-Y-00 Flex 4-Gas Monitor, LEL/O2/H2S/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Diffusion · Battery: Yes · Sensor ranges: LEL 100% LEL; O2 25% VOL; H2S 100 ppm; CO 1000 ppm · Approvals: ATEX, IEC Ex, CSA, FTZU, INMETRO, GOSST, CCCF, CPA, KRS, MED, DNV, SABS, FCCID, IC, UKCA, CE; ATEX, IECEX
  • BW Technologies CPD-W7X1H1M1-B-00 Flex 4-Gas Monitor, LEL/O2/H2S/CO, Black — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Diffusion · Battery: Yes · Sensor ranges: LEL 100% LEL; O2 25% VOL; H2S 100 ppm; CO 1000 ppm · Approvals: ATEX, IEC Ex, CSA, FTZU, INMETRO, GOSST, CCCF, CPA, KRS, MED, DNV, SABS, FCCID, IC, UKCA, CE; ATEX, IECEX
  • BW Technologies HRR-A300009ABK-000 RigRat Area Gas Monitor, LEL/O2/H2S/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Battery: Yes · Sensor ranges: LEL 0-100%LEL; O2 0-30%vol; H2S 0-1000ppm; CO 0-2000ppm · Approvals: cETLus Class I Division 1; Group A, B, C, D; T4;; IEEE 802.15.4 868
  • BW Technologies HRR-A300100ABK-000 RigRat Area Gas Monitor, LEL/O2/H2S/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Battery: Yes · Sensor ranges: LEL 0-100%LEL; O2 0-30%vol; H2S 0-1000ppm; CO 0-2000ppm · Approvals: cETLus Class I Division 1; Group A, B, C, D; T4;; IEEE 802.15.4 868
  • BW Technologies HRR-B300009ABK-000 RigRat Area Gas Monitor, LEL/O2/H2S/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Battery: Yes · Sensor ranges: LEL 0-100%LEL; O2 0-30%vol; H2S 0-1000ppm; CO 0-2000ppm · Approvals: cETLus Class I Division 1; Group A, B, C, D; T4;; IEEE 802.15.4 868
  • BW Technologies HRR-B300100ABK-000 RigRat Area Gas Monitor, LEL/O2/H2S/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Battery: Yes · Sensor ranges: LEL 0-100%LEL; O2 0-30%vol; H2S 0-1000ppm; CO 0-2000ppm · Approvals: cETLus Class I Division 1; Group A, B, C, D; T4;; IEEE 802.15.4 868
  • BW Technologies HRR-C301009ABK-000 RigRat Area Gas Monitor, LEL/O2/H2S/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Battery: Yes · Sensor ranges: LEL 0-100%LEL; O2 0-30%vol; H2S 0-1000ppm; CO 0-2000ppm · Approvals: cETLus Class I Division 1; Group A, B, C, D; T4;; IEEE 802.15.4 868
  • BW Technologies HRR-C301100ABK-100 RigRat Area Gas Monitor, LEL/O2/H2S/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Battery: Yes · Sensor ranges: LEL 0-100%LEL; O2 0-30%vol; H2S 0-1000ppm; CO 0-2000ppm · Approvals: cETLus Class I Division 1; Group A, B, C, D; T4;; IEEE 802.15.4 868
  • BW Technologies HRR-C303100ABK-000 RigRat Area Gas Monitor, LEL/O2/H2S/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Battery: Yes · Sensor ranges: LEL 0-100%LEL; O2 0-30%vol; H2S 0-1000ppm; CO 0-2000ppm · Approvals: cETLus Class I Division 1; Group A, B, C, D; T4;; IEEE 802.15.4 868
  • BW Technologies HRR-D301009ABK-000 RigRat Area Gas Monitor, LEL/O2/H2S/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Battery: Yes · Sensor ranges: LEL 0-100%LEL; O2 0-30%vol; H2S 0-1000ppm; CO 0-2000ppm · Approvals: cETLus Class I Division 1; Group A, B, C, D; T4;; IEEE 802.15.4 868
  • BW Technologies HRR-G301009ABK-000 RigRat Area Gas Monitor, LEL/O2/H2S/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Battery: Yes · Sensor ranges: LEL 0-100%LEL; O2 0-30%vol; H2S 0-1000ppm; CO 0-2000ppm · Approvals: cETLus Class I Division 1; Group A, B, C, D; T4;; IEEE 802.15.4 868
  • BW Technologies HRR-G301100ABK-100 RigRat Area Gas Monitor, LEL/O2/H2S/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Battery: Yes · Sensor ranges: LEL 0-100%LEL; O2 0-30%vol; H2S 0-1000ppm; CO 0-2000ppm · Approvals: cETLus Class I Division 1; Group A, B, C, D; T4;; IEEE 802.15.4 868
  • BW Technologies HRR-H301009ABK-000 RigRat Area Gas Monitor, LEL/O2/H2S/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Battery: Yes · Sensor ranges: LEL 0-100%LEL; O2 0-30%vol; H2S 0-1000ppm; CO 0-2000ppm · Approvals: cETLus Class I Division 1; Group A, B, C, D; T4;; IEEE 802.15.4 868
  • BW Technologies HRR-H301100ABK-100 RigRat Area Gas Monitor, LEL/O2/H2S/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Battery: Yes · Sensor ranges: LEL 0-100%LEL; O2 0-30%vol; H2S 0-1000ppm; CO 0-2000ppm · Approvals: cETLus Class I Division 1; Group A, B, C, D; T4;; IEEE 802.15.4 868
  • BW Technologies HU-X1W100M1A1-Y-N Ultra 4-Gas Monitor, LEL/O2/CO/NH3 — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; CO; NH3 · Gases: 4 gases · Sampling: Pump (sample draw) · Battery: Yes · Sensor ranges: LEL 0-100%LEL; O2 0-25%; CO 0-2000ppm; NH3 0-100ppm · Approvals: ATEX: II 1G Ex ia IIC T4 Ga; CE European Conformity
  • BW Technologies HU-X1W1H1M1S1-Y-N Ultra 5-Gas Monitor, LEL/O2/H2S/CO/SO2 — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO; SO2 · Gases: 5 gases · Sampling: Pump (sample draw) · Battery: Yes · Sensor ranges: LEL 0-100%LEL; O2 0-25%; H2S 0-100ppm; CO 0-2000ppm; SO2 0-100ppm · Approvals: ATEX: II 1G Ex ia IIC T4 Ga; CE European Conformity
  • BW Technologies MCX3-XW00-Y-NA MicroClip X3 2-Gas Monitor, LEL/O2 — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2 · Gases: 2 gases · Sampling: Diffusion · Battery: Yes · Sensor ranges: LEL 0-100% and 0-5.0% v/v; O2 0 to 30.0% · Approvals: ATEX: CE II 1 G. Ex ia IIC T4 Ga; CE European Conformity
  • BW Technologies MCX3-XW0M-Y-NA MicroClip X3 3-Gas Monitor, LEL/O2/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; CO · Gases: 3 gases · Sampling: Diffusion · Battery: Yes · Sensor ranges: LEL 0-100% and 0-5.0% v/v; O2 0 to 30.0%; CO 0-500 ppm · Approvals: ATEX: CE II 1 G. Ex ia IIC T4 Ga; CE European Conformity
  • BW Technologies MCX3-XWHM-B-NA MicroClip X3 4-Gas Monitor, LEL/O2/H2S/CO, Black — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Diffusion · Battery: Yes · Sensor ranges: LEL 0-100% and 0-5.0% v/v; O2 0 to 30.0%; H2S 0-100 ppm; CO 0-500 ppm · Approvals: ATEX: CE II 1 G. Ex ia IIC T4 Ga; CE European Conformity
  • BW Technologies MCX3-XWHM-Y-NA MicroClip X3 4-Gas Monitor, LEL/O2/H2S/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 5 gases · Sampling: Diffusion · Battery: Yes · Sensor ranges: LEL 0-100% and 0-5.0% v/v; O2 0 to 30.0%; H2S 0-100 ppm; CO 0-500 ppm · Approvals: ATEX: CE II 1 G. Ex ia IIC T4 Ga; CE European Conformity
  • BW Technologies MCXL-00HM-Y-NA MicroClip XL 2-Gas Monitor, H2S/CO — BW Technologies / Honeywell Analytics · Gases detected: H2S; CO · Gases: 2 gases · Sampling: Diffusion · Battery: Yes · Sensor ranges: H2S 0-100 ppm; CO 0-500 ppm · Approvals: ATEX: CE II 1 G. Ex ia IIC T4 Ga; CE European Conformity
  • BW Technologies MCXL-X000-Y-NA MicroClip XL Oxygen Monitor — BW Technologies / Honeywell Analytics · Gases detected: O2 · Gases: 1 gas · Sampling: Diffusion · Battery: Yes · Sensor ranges: O2 0 to 30.0% · Approvals: ATEX: CE II 1 G. Ex ia IIC T4 Ga; CE European Conformity
  • BW Technologies MCXL-X00M-Y-NA MicroClip XL 2-Gas Monitor, O2/CO — BW Technologies / Honeywell Analytics · Gases detected: O2; CO · Gases: 2 gases · Sampling: Diffusion · Battery: Yes · Sensor ranges: O2 0 to 30.0%; CO 0-500 ppm · Approvals: ATEX: CE II 1 G. Ex ia IIC T4 Ga; CE European Conformity
  • BW Technologies MCXL-X0H0-B-NA MicroClip XL 2-Gas Monitor, O2/H2S, Black — BW Technologies / Honeywell Analytics · Gases detected: O2; H2S · Gases: 2 gases · Sampling: Diffusion · Battery: Yes · Sensor ranges: O2 0 to 30.0%; H2S 0-100 ppm · Approvals: ATEX: CE II 1 G. Ex ia IIC T4 Ga; CE European Conformity
  • BW Technologies MCXL-X0H0-Y-NA MicroClip XL 2-Gas Monitor, O2/H2S — BW Technologies / Honeywell Analytics · Gases detected: O2; H2S · Gases: 2 gases · Sampling: Diffusion · Battery: Yes · Sensor ranges: O2 0 to 30.0%; H2S 0-100 ppm · Approvals: ATEX: CE II 1 G. Ex ia IIC T4 Ga; CE European Conformity
  • BW Technologies MCXL-X0HM-Y-NA MicroClip XL 3-Gas Monitor, O2/H2S/CO — BW Technologies / Honeywell Analytics · Gases detected: O2; H2S; CO · Gases: 3 gases · Sampling: Diffusion · Battery: Yes · Sensor ranges: O2 0 to 30.0%; H2S 0-100 ppm; CO 0-500 ppm · Approvals: ATEX: CE II 1 G. Ex ia IIC T4 Ga; CE European Conformity
  • BW Technologies MCXL-XW00-B-NA MicroClip XL 2-Gas Monitor, LEL/O2, Black — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2 · Gases: 2 gases · Sampling: Diffusion · Battery: Yes · Sensor ranges: LEL 0-100% and 0-5.0% v/v; O2 0 to 30.0% · Approvals: ATEX: CE II 1 G. Ex ia IIC T4 Ga; CE European Conformity
  • BW Technologies MCXL-XW00-Y-NA MicroClip XL 2-Gas Monitor, LEL/O2 — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2 · Gases: 2 gases · Sampling: Diffusion · Battery: Yes · Sensor ranges: LEL 0-100% and 0-5.0% v/v; O2 0 to 30.0% · Approvals: ATEX: CE II 1 G. Ex ia IIC T4 Ga; CE European Conformity
  • BW Technologies MCXL-XW0M-Y-NA MicroClip XL 3-Gas Monitor, LEL/O2/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; CO · Gases: 3 gases · Sampling: Diffusion · Battery: Yes · Sensor ranges: LEL 0-100% and 0-5.0% v/v; O2 0 to 30.0%; CO 0-500 ppm · Approvals: ATEX: CE II 1 G. Ex ia IIC T4 Ga; CE European Conformity
  • BW Technologies MCXL-XWH0-Y-NA MicroClip XL 3-Gas Monitor, LEL/O2/H2S — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S · Gases: 3 gases · Sampling: Diffusion · Battery: Yes · Sensor ranges: LEL 0-100% and 0-5.0% v/v; O2 0 to 30.0%; H2S 0-100 ppm · Approvals: ATEX: CE II 1 G. Ex ia IIC T4 Ga; CE European Conformity
  • BW Technologies MCXL-XWHM-B-NA MicroClip XL 4-Gas Monitor, LEL/O2/H2S/CO, Black — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Diffusion · Battery: Yes · Sensor ranges: LEL 0-100% and 0-5.0% v/v; O2 0 to 30.0%; H2S 0-100 ppm; CO 0-500 ppm · Approvals: ATEX: CE II 1 G. Ex ia IIC T4 Ga; CE European Conformity
  • BW Technologies MCXL-XWHM-Y-NA MicroClip XL 4-Gas Monitor, LEL/O2/H2S/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Diffusion · Battery: Yes · Sensor ranges: LEL 0-100% and 0-5.0% v/v; O2 0 to 30.0%; H2S 0-100 ppm; CO 0-500 ppm · Approvals: ATEX: CE II 1 G. Ex ia IIC T4 Ga; CE European Conformity
  • BW Technologies XT-XUHM-Y-NA Max XT II 4-Gas Monitor, LEL/O2/H2S/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Battery: Yes · Sensor ranges: LEL 0-100% and 0-5.0% v/v; O2 0 to 30.0%; H2S 0-200 ppm · Approvals: ATEX: X g II 1 G Ga Ex ia IIC T4; BR-Exia IIC T4
  • BW Technologies XT-XW00-Y-NA Max XT II 2-Gas Monitor, LEL/O2 — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2 · Gases: 2 gases · Sampling: Pump (sample draw) · Battery: Yes · Sensor ranges: LEL 0-100% and 0-5.0% v/v; O2 0 to 30.0% · Approvals: ATEX: X g II 1 G Ga Ex ia IIC T4; BR-Exia IIC T4
  • BW Technologies XT-XW0M-Y-NA Max XT II 3-Gas Monitor, LEL/O2/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; CO · Gases: 3 gases · Sampling: Pump (sample draw) · Battery: Yes · Sensor ranges: LEL 0-100% and 0-5.0% v/v; O2 0 to 30.0% · Approvals: ATEX: X g II 1 G Ga Ex ia IIC T4; BR-Exia IIC T4
  • BW Technologies XT-XWH0-Y-NA Max XT II 3-Gas Monitor, LEL/O2/H2S — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S · Gases: 3 gases · Sampling: Pump (sample draw) · Battery: Yes · Sensor ranges: LEL 0-100% and 0-5.0% v/v; O2 0 to 30.0%; H2S 0-200 ppm · Approvals: ATEX: X g II 1 G Ga Ex ia IIC T4; BR-Exia IIC T4
  • BW Technologies XT-XWHM-B-NA Max XT II 4-Gas Monitor, LEL/O2/H2S/CO, Black — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Battery: Yes · Sensor ranges: LEL 0-100% and 0-5.0% v/v; O2 0 to 30.0%; H2S 0-200 ppm · Approvals: ATEX: X g II 1 G Ga Ex ia IIC T4; BR-Exia IIC T4
  • BW Technologies XT-XWHM-Y-NA Max XT II 4-Gas Monitor, LEL/O2/H2S/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Battery: Yes · Sensor ranges: LEL 0-100% and 0-5.0% v/v; O2 0 to 30.0%; H2S 0-200 ppm · Approvals: ATEX: X g II 1 G Ga Ex ia IIC T4; BR-Exia IIC T4
  • BW Technologies XT-XWHM-Y-NA-CS Max XT II 4-Gas Monitor, LEL/O2/H2S/CO — BW Technologies / Honeywell Analytics · Gases detected: LEL; O2; H2S; CO · Gases: 4 gases · Sampling: Pump (sample draw) · Battery: Yes · Sensor ranges: LEL 0-100% and 0-5.0% v/v; O2 0 to 30.0%; H2S 0-200 ppm · Approvals: ATEX: X g II 1 G Ga Ex ia IIC T4; BR-Exia IIC T4

Do not see what you need? Browse the category or call (925) 215-7337.

A gas monitor is described by the gases it detects (LEL for combustibles, O2 for oxygen, H2S, CO, and so on), how many it detects at once, whether it samples by diffusion (air reaches the sensors on its own) or with a pump (sample draw, for checking a space before entry), how it is powered, and the approvals that let it be used in a classified area. All of these are the manufacturer's published specifications; alarm points and calibration intervals follow the manufacturer's manual.

Technical. Intrinsic-safety approvals are listed as the manufacturer prints them (UL or CSA Class I Division 1 Groups A–D, ATEX and IECEx Ex ia IIC T4 marks). Sensor ranges are quoted per gas (for example 0–100% LEL, 0–30% volume O2, 0–100 ppm H2S, 0–500 ppm CO; PID sensors for VOCs in ppm or ppb with the lamp energy in eV; IR sensors for CO2 or methane). Calibration gas is matched to the monitor's sensors and listed by concentration. Draeger detector tubes have their own selector page.

The ratings, test results and standards shown here are the manufacturers' published values, reproduced as published. Nothing on this page is a recommendation by Bayshore Safety that any product is suitable for a particular task, hazard or workplace. Selecting safety products and protective equipment is the responsibility of the end user and the employer, based on their own hazard assessment and the regulations that apply to their work. Confirm every value on the manufacturer's own documentation before use.

The standard at a glance

Copied from the named standard or regulation and shown with its source; nothing in these tables is Bayshore's recommendation.

OSHA confined-space atmosphere limits
Condition (29 CFR 1910.146)Limit
Oxygen deficientBelow 19.5% oxygen
Oxygen enrichedAbove 23.5% oxygen
FlammableAbove 10% of the lower flammable limit (LFL)
ToxicAbove the substance's permissible exposure limit (29 CFR 1910 Subpart Z)
Approval mark (as printed by the manufacturer)Meaning
UL or CSA Class I, Division 1, Groups A–DIntrinsically safe for flammable gas and vapour atmospheres (North America)
ATEX / IECEx Ex ia IIC T4Intrinsically safe, gas group IIC, temperature class T4 (Europe / international)

Source: OSHA 29 CFR 1910.146 (permit-required confined spaces). Alarm set points and calibration intervals follow each manufacturer's manual. Draeger detector tubes have their own selector.

Need help choosing?Call us with the job and the hazard; we will point you at the products the manufacturers rate for it.
Call (925) 215-7337
How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.