MSA Single-Gas Monitors
14 single-gas monitors from MSA, listed with what MSA publishes.
Pick a gas, number of gases, sampling or battery; the list below narrows as you choose.

14 products
Ratings and specifications are as published by each manufacturer. Tap a group to open it.
MSA14 products
- MSA 10071361 ALTAIR Single-Gas H2S Monitor, 5/10 ppm Alarms — MSA · Gases detected: H2S · Gases: 1 gas · Sampling: Diffusion · Battery: Sealed · Sensor ranges: H2S alarms 10 ppm first, 15 ppm second (alternate set point models 10/20, 5/10 and 7/14 ppm) · Approvals: CSA; ATEX
- MSA 10071364 ALTAIR Single-Gas Oxygen Monitor, 19.5/18.0% Alarms — MSA · Gases detected: O2 · Gases: 1 gas · Sampling: Diffusion · Battery: Sealed · Sensor ranges: O2 alarms 19.5% vol, 23% vol (alternate set point model 19.5% / 18%) · Approvals: CSA; ATEX
- MSA 10074137 ALTAIR Pro Oxygen Monitor, 19.5/23.0% Alarms, Black — MSA · Gases detected: O2 · Gases: 1 gas · Sampling: Diffusion · Battery: 3 V CR2 battery (MSA 10074132) · Sensor ranges: O2 alarms 19.50% low, 23.00% high (alternate set point model 18.00% / 19.50%) · Approvals: CSA; IECEx
- MSA 10076717 ALTAIR Pro Chlorine Dioxide Detector, 0.1/0.3 ppm Alarms — MSA · Gases detected: ClO2 · Gases: 1 gas · Sampling: Diffusion · Battery: 3 V CR2 battery (MSA 10074132) · Sensor ranges: ClO2 alarms 0.1 ppm low, 0.3 ppm high, STEL 0.3 ppm, TWA 0.1 ppm · Approvals: CSA; IECEx
- MSA 10092521 ALTAIR Single-Gas H2S Monitor, 10/15 ppm Alarms, Black — MSA · Gases detected: H2S · Gases: 1 gas · Sampling: Diffusion · Battery: Sealed · Sensor ranges: H2S alarms 10 ppm first, 15 ppm second (alternate set point models 10/20, 5/10 and 7/14 ppm) · Approvals: CSA; ATEX
- MSA 10092522 ALTAIR Single-Gas Portable CO Monitor, 25/100 ppm Alarms — MSA · Gases detected: CO · Gases: 1 gas · Sampling: Diffusion · Battery: Sealed · Sensor ranges: CO alarms 25 ppm first, 100 ppm second (alternate set point models 30/60 and 35/100 ppm) · Approvals: CSA; ATEX
- MSA 10092523 ALTAIR Single-Gas Oxygen Monitor, 19.5/23.0% Alarms, Black — MSA · Gases detected: O2 · Gases: 1 gas · Sampling: Diffusion · Battery: Sealed · Sensor ranges: O2 alarms 19.5% vol, 23% vol (alternate set point model 19.5% / 18%) · Approvals: CSA; ATEX
- MSA 10153984 ALTAIR 2X H2S Monitor, 10/15 ppm Alarms, 2XP — MSA · Gases detected: H2S · Gases: 1 gas · Sampling: Diffusion · Battery: Replaceable lithium battery · Sensor ranges: H2S 0-200 ppm (H2S-LC 0-100 ppm) · Approvals: CSA Class I Div 1 Groups A, B, C, D; ATEX; IECEx
- MSA 10153986 ALTAIR 2X Portable CO Monitor, 25/100 ppm Alarms, 2X — MSA · Gases detected: CO · Gases: 1 gas · Sampling: Diffusion · Battery: Replaceable lithium battery · Sensor ranges: CO 0-1999 ppm (XCell CO/H2S two-tox or single) · Approvals: CSA Class I Div 1 Groups A, B, C, D; ATEX; IECEx
- MSA 10154073 ALTAIR 2X 2-Gas Monitor, CO/NO2, 2XT — MSA · Gases detected: CO; NO2 · Gases: 2 gases · Sampling: Diffusion · Battery: Replaceable lithium battery · Sensor ranges: CO 0-1999 ppm (XCell CO/H2S two-tox or single); NO2 0-50 ppm · Approvals: CSA Class I Div 1 Groups A, B, C, D; ATEX; IECEx
- MSA 10154077 ALTAIR 2X SO2 Detector, 2/5 ppm Alarms, 2X — MSA · Gases detected: SO2 · Gases: 1 gas · Sampling: Diffusion · Battery: Replaceable lithium battery · Sensor ranges: SO2 0-20 ppm · Approvals: CSA Class I Div 1 Groups A, B, C, D; ATEX; IECEx
- MSA 10154078 ALTAIR 2X NO2 Detector, 2.5/5 ppm Alarms, 2X — MSA · Gases detected: NO2 · Gases: 1 gas · Sampling: Diffusion · Battery: Replaceable lithium battery · Sensor ranges: NO2 0-50 ppm · Approvals: CSA Class I Div 1 Groups A, B, C, D; ATEX; IECEx
- MSA 10154079 ALTAIR 2X Ammonia Detector, 25/50 ppm Alarms, 2X — MSA · Gases detected: NH3 · Gases: 1 gas · Sampling: Diffusion · Battery: Replaceable lithium battery · Sensor ranges: NH3 0-100 ppm · Approvals: CSA Class I Div 1 Groups A, B, C, D; ATEX; IECEx
- MSA 10154080 ALTAIR 2X Chlorine Gas Detector, 0.5/1 ppm Alarms, 2X — MSA · Gases detected: Cl2 · Gases: 1 gas · Sampling: Diffusion · Battery: Replaceable lithium battery · Sensor ranges: Cl2 0-10 ppm · Approvals: CSA Class I Div 1 Groups A, B, C, D; ATEX; IECEx
Do not see what you need? Browse the category or call (925) 215-7337.
A gas monitor is described by the gases it detects (LEL for combustibles, O2 for oxygen, H2S, CO, and so on), how many it detects at once, whether it samples by diffusion (air reaches the sensors on its own) or with a pump (sample draw, for checking a space before entry), how it is powered, and the approvals that let it be used in a classified area. All of these are the manufacturer's published specifications; alarm points and calibration intervals follow the manufacturer's manual.
Technical. Intrinsic-safety approvals are listed as the manufacturer prints them (UL or CSA Class I Division 1 Groups A–D, ATEX and IECEx Ex ia IIC T4 marks). Sensor ranges are quoted per gas (for example 0–100% LEL, 0–30% volume O2, 0–100 ppm H2S, 0–500 ppm CO; PID sensors for VOCs in ppm or ppb with the lamp energy in eV; IR sensors for CO2 or methane). Calibration gas is matched to the monitor's sensors and listed by concentration. Draeger detector tubes have their own selector page.
The ratings, test results and standards shown here are the manufacturers' published values, reproduced as published. Nothing on this page is a recommendation by Bayshore Safety that any product is suitable for a particular task, hazard or workplace. Selecting safety products and protective equipment is the responsibility of the end user and the employer, based on their own hazard assessment and the regulations that apply to their work. Confirm every value on the manufacturer's own documentation before use.
The standard at a glance
Copied from the named standard or regulation and shown with its source; nothing in these tables is Bayshore's recommendation.
OSHA confined-space atmosphere limits
| Condition (29 CFR 1910.146) | Limit |
|---|---|
| Oxygen deficient | Below 19.5% oxygen |
| Oxygen enriched | Above 23.5% oxygen |
| Flammable | Above 10% of the lower flammable limit (LFL) |
| Toxic | Above the substance's permissible exposure limit (29 CFR 1910 Subpart Z) |
| Approval mark (as printed by the manufacturer) | Meaning |
|---|---|
| UL or CSA Class I, Division 1, Groups A–D | Intrinsically safe for flammable gas and vapour atmospheres (North America) |
| ATEX / IECEx Ex ia IIC T4 | Intrinsically safe, gas group IIC, temperature class T4 (Europe / international) |
Source: OSHA 29 CFR 1910.146 (permit-required confined spaces). Alarm set points and calibration intervals follow each manufacturer's manual. Draeger detector tubes have their own selector.