Bayshore Safety & Industrial Supplies Guide
Oxy-fuel cutting tip sizes: which tip for which plate thickness, acetylene vs propane tips, and the pressures the makers publish? Reading a tip number (000 to 6), one-piece acetylene vs two-piece propane and propylene tips, oxygen and fuel pressures by size, kerf, preheat and cutting oxygen, tip cleaners and dressing, gouging and heating tips, and why the chart is the only source
A cutting tip is chosen by the thickness of the steel and the fuel gas, from the chart the torch maker publishes for that tip series, and the chart also states the oxygen and fuel pressures and the kerf. Tip sizes run from 000 (sheet, 1/8 inch and under) through 00 (to 1/4), 0 (to 1/2), 1 (to 3/4 or 1), 2 (to 1-1/2 or 2), 3 (to 2-1/2 or 3), 4 (to 4), 5 (to 6) and 6 (to 8 and 10 inch), with the exact ranges differing by maker (Victor, Harris and Smith number the same way but their charts are not interchangeable). Acetylene tips are one piece with the preheat holes drilled in a ring around the cutting oxygen bore; propane, propylene and natural gas burn with a slower flame and need a two-piece tip (a splined inner and an outer shell) that holds the flame and gives a larger preheat area, and the two are not swapped between fuels. Pressures from a typical chart: a size 0 tip for 1/2 inch plate at about 30 to 35 psi oxygen and 3 to 5 psi acetylene, a size 2 for 1-1/2 inch at 45 to 50 and 5 to 7, a size 4 for 4 inch at 60 to 75 and 7 to 10, always with acetylene under the 15 psig limit; propane runs similar oxygen and 4 to 10 psi fuel, and uses more oxygen for the same cut. Tip orifices are cleaned with the wire of a tip cleaner that fits the hole without reaming it, and the seat is never cleaned with anything but the maker’s tool; a tip with a bell-mouthed or scored orifice is replaced. Gouging tips remove a groove of metal, heating (rosebud) tips put heat into a large area and have their own, higher gas requirements. The band lists the cutting, heating and gouging tips and the tip cleaners we stock by series and size.
Why the tip chart is the whole answer. Every torch maker publishes a chart for each tip series giving the size for each plate thickness, the pressures at the regulator for a given hose length, the cutting speed and the kerf width. The pressures and sizes in this guide are examples from those charts to show the pattern; the chart for the tip in the torch is the source, because tip series differ, and a tip run at the wrong pressure backfires or cuts badly. The cards go through size, fuel, pressure, cleaning and the special tips.
Cutting tips, question by question
Figures are the pattern from the makers’ charts; the chart for your tip series governs.
In plain words
- Tip size follows plate thickness: 0 for half inch, 2 for an inch and a half, 4 for four inches; the maker’s chart decides.
- Acetylene uses one-piece tips; propane and propylene need two-piece tips, more oxygen and Grade T hose.
- Set pressures from the chart with the torch flowing; acetylene never above 15 psig.
- Offset the layout by half the kerf.
- Clean with the right wire straight in; dress the face with the file; never ream the hole.
- Backfire pops; flashback squeals: oxygen off, then fuel, find the cause.
Questions people ask
What size cutting tip for 1/2 inch steel?
A size 0 tip on most makers’ charts, at roughly 30 to 35 psi oxygen and 3 to 5 psi acetylene; the chart for the tip series governs.
Can you use an acetylene tip with propane?
No; propane needs a two-piece tip with a larger preheat area, and the hose must be Grade T.
What should oxygen and acetylene pressures be for cutting?
Whatever the tip chart lists for the tip size and thickness, set with the torch flowing; acetylene never above 15 psig.
How do you clean a cutting torch tip?
With the matching wire from a tip cleaner set, straight in and out, after dressing the face flat with the file in the set; never a drill bit.
What is kerf in oxy-fuel cutting?
The width of the cut, about the orifice size plus a little; layout is offset by half of it.
What is the difference between a backfire and a flashback?
A backfire is a pop at the tip; a flashback is the flame burning back inside the torch and is stopped by closing oxygen, then fuel.
Related guides
Oxy-fuel regulators, CGA connections and flashback arrestorsThe regulators behind the tip chartOxygen and acetylene cylinder storage and handlingThe cylindersPlasma cutter vs oxy-fuel torchWhen plasma replaces the torchWelding lens shade chartShades for cutting by tip sizeHot work permitsThe 35 foot rule and fire watchSpark lighters, cutting guides and welding magnetsLighting and guiding the torchThe ratings, test results and standards shown here are the manufacturers' published values, reproduced as published. Nothing on this page is a recommendation by Bayshore Safety that any product is suitable for a particular task, hazard or workplace. Selecting safety products and protective equipment is the responsibility of the end user and the employer, based on their own hazard assessment and the regulations that apply to their work. Confirm every value on the manufacturer's own documentation before use.
© 2026 Bayshore Safety & Industrial Supplies, Inc. All rights reserved. This guide may not be copied or republished without written permission.