Skip to main content
Home › Guides › Janitorial and hand hygiene › Shop towels and oily waste
Guide · Janitorial and hand hygiene · Disposable vs laundered wipers, the EPA solvent-contaminated wipes rule, 1910.106 and NFPA 30 oily waste cans

Bayshore Safety & Industrial Supplies Guide

Shop towels, rags and oily waste cans: disposable vs laundered wipers, the EPA solvent-contaminated wipes rule, why oily rags self-ignite and what 1910.106, 1926.252 and NFPA 30 require for the can? Red shop towels, DRC and hydroknit wipers, WypAll grades, cotton rags by the box, the 2013 EPA rule (40 CFR 261.4(a)(26) and (b)(18)) on reusable and disposable solvent wipes, spontaneous heating of linseed, stain and cutting oils, the UL-listed oily waste can with its foot pedal and raised bottom, emptying daily, and what goes to the laundry vs the drum

A wiper in a shop is a laundered textile (the red cotton shop towel, white knit rags, terry) supplied by the shop or an industrial laundry, a cut rag by the box (reclaimed cotton T-shirt, flannel and sweatshirt material sold by the pound, with lint and variable size), or a disposable nonwoven (DRC double re-creped cellulose and polypropylene in the Kimberly-Clark WypAll X series and Georgia-Pacific Brawny Industrial, hydroknit, spunlace, meltblown oil-only pads), sold on rolls, in pop-up boxes and in quarter-fold packs, graded by strength and absorbency (WypAll L for light, X60 and X70 for solvents and general, X80 and X90 for heavy duty and reuse within a shift). The choice sets the waste path: used wipers with oil, solvent or finish are a fire and a hazardous waste question before they are a trash question. Fire: oils that dry by oxidation (linseed, tung, boiled oils, some stains, varnishes and alkyd finishes, and to a lesser degree cutting and lube oils soaked in bulk) heat as they cure, and a pile of rags insulates that heat until it ignites, which is the spontaneous-heating fire the NFPA fire investigation data traces to finish rags in a bucket; the rule is a UL-listed oily waste can (Justrite, Eagle), steel, with a self-closing lid on a foot pedal that keeps the lid shut without hands, an elevated bottom that lets air circulate under the can so heat dissipates, and a capacity of 6 to 21 gallons, emptied daily or at the end of the shift into an outside drum or the laundry pickup, never left full overnight. OSHA 1910.106(e)(9)(iii) requires combustible waste material and residues in a building kept to a minimum, stored in covered metal receptacles and disposed of daily; 1926.252(e) requires oily rags, waste and other flammable waste in covered metal containers on construction sites; NFPA 30 and the fire codes (IFC 304.3.1) require oily rags and similar material in listed disposal containers with self-closing lids; 1910.1200 and the SDS set the glove for the solvent. Waste: the EPA’s 2013 solvent-contaminated wipes rule, 40 CFR 261.4(a)(26) and (b)(18), excludes reusable wipes sent to a laundry and disposable wipes sent to a permitted landfill or combustor from hazardous waste regulation when the wipes contain no free liquid (the paint filter test), are kept in closed, labeled containers (Excluded Solvent-Contaminated Wipes), are accumulated no more than 180 days, and are not contaminated with trichloroethylene (disposable) or the listed hazardous wastes the rule excludes; wipes with free liquid, with hazardous metals or with other hazardous waste are managed under the generator rules, and used oil wipers follow the used oil rules and the laundry’s acceptance terms. The band lists the shop towels, rags, nonwoven wipers, dispensers and oily waste cans we stock.

Bayshore Safety. Industrial safety and PPE supplier since 2017. · Current as of November 2026 · 29 CFR 1910.106(e)(9)(iii), Flammable liquids, industrial plants, housekeeping; 1926.252(e), Disposal of waste materials (osha.gov); NFPA 30, Flammable and Combustible Liquids Code, and NFPA 1 and IFC 304.3.1 on oily waste and listed disposal containers; UL 32 (metal waste cans); EPA, 40 CFR 261.4(a)(26) and (b)(18), Conditional exclusions for solvent-contaminated wipes (the 2013 wipes rule), and 40 CFR 279, Used oil; the Kimberly-Clark WypAll, Georgia-Pacific Brawny Industrial, Tork, Scott, Justrite and Eagle product data on this site (wiper grade, basis, count, can capacity and listing as printed)

Why the stain rags burned the shop down without a spark. A drying oil cures by taking oxygen from the air and giving off heat; in a pile the heat has nowhere to go and the pile lights itself. The oily waste can is built around that one fact, and the EPA wipes rule is built around the solvent that the rag is also carrying. The cards cover the wiper types and grades, the fire mechanism and the can, the OSHA and fire code paragraphs, the EPA rule and the laundry path.

Wipers and oily waste, question by question

The can requirements are OSHA 1910.106 and 1926.252 and the fire codes; the waste rule is EPA 40 CFR 261.4; the wiper grades are the makers’ specifications.

Disposable nonwoven, laundered towel or cut rag?Laundered shop towels (red or blue cotton, 13 by 14 inch, the industrial laundry service or purchased by the bale): absorbent, reusable, no lint after the first washes; the laundry takes the solvent and oil waste under the EPA reusable-wipes exclusion; the laundry sets what it accepts and the towels come back with some residual solvent and metals, which is why food, clean assembly and paint prep shops moved to disposables. Cut rags by the box (25 and 50 pound; white knit T-shirt for lint-free wiping, colored knit, flannel, terry, sweatshirt): cheapest per pound, mixed sizes and seams, lint from some materials, one use then the oily waste can or the drum. Disposable nonwovens: DRC (double re-creped cellulose-polypropylene, WypAll X60 to X90, Brawny Industrial, Tork Heavy-Duty) for solvent, oil and general wiping with controlled lint, strength when wet, and a defined waste stream; hydroknit and spunlace for low-lint; meltblown polypropylene for oil-only (the spill pad); microfiber for glass and finish. Formats: jumbo roll on a floor stand or wall dispenser, center-pull, pop-up box, quarter-fold in a bucket or brag box, and wet wipes pre-saturated for hands and tools. The grade number is strength and absorbency, not a safety rating.
Why do oily rags catch fire by themselves?Drying oils (linseed, tung, Danish and teak oils, boiled linseed, oil-based stains, varnishes and alkyd paints that cure by oxidation) react with oxygen as they cure, and the reaction releases heat; a single rag spread flat loses the heat, but a rag balled up or a pile in a bucket, a cardboard box or a plastic bag insulates it, the temperature rises, the reaction speeds up with temperature, and within a few hours the pile reaches the ignition temperature of the oil-soaked cloth. NFPA and the fire marshals log these as spontaneous-heating fires, typically in the night after a staining job. Petroleum lube and cutting oils, fuels and solvents do not self-heat the same way, but a rag soaked in them is fuel waiting for the source, so the same can holds them. The three safe states for a finish rag: hung flat outdoors to cure fully (then trash), submerged in water in a sealed metal can, or in the listed oily waste can emptied the same day. Never a plastic bag, a cardboard box, a pile on the bench or the general trash.
What is an oily waste can, and what makes it compliant?A steel can listed to UL 32 or FM-approved (Justrite 09100 to 09700 and 09300 series, Eagle 930 to 937), with a self-closing lid that is opened by a foot pedal so hands stay free and the lid never stays open, a lid that seals the opening to starve a fire of oxygen, and an elevated bottom (legs or a raised base) that lets air circulate under the can to carry heat away so the contents do not heat up; sizes 6, 10, 14 and 21 gallon, in red (oily waste) or yellow (with a solvent or label by the shop’s color scheme); the label says oily waste only. The can sits away from heat sources and exits, is emptied at the end of each shift or at least daily into an outdoor metal drum with a lid (or the laundry pickup bag), and is never used for general trash, aerosol cans or cigarette butts. The fire code allows the contents to accumulate only in the can; the cardboard box by the paint bench is the violation inspectors write, and the plastic can with a swing lid is not a substitute.
What do OSHA and the fire codes say?1910.106(e)(9)(iii), for industrial plants handling flammable liquids: combustible waste material and residues in a building or unit operating area kept to a minimum, stored in covered metal receptacles and disposed of daily. 1926.252(e): all solvent waste, oily rags and flammable liquids kept in fire-resistant covered containers until removed from the worksite. 1910.107(g)(3), spray finishing: rags and waste impregnated with finishing material deposited in approved waste cans immediately after use and removed daily. 1910.141(a)(4) covers the general receptacle. IFC 304.3.1 and NFPA 1 require oily rags and similar material stored in listed disposal containers with self-closing lids; NFPA 30 chapter 18 applies the same to processing areas. California Fire Code adopts the IFC language. An insurer’s inspection and the fire marshal look for the listed can, the daily emptying, and the outdoor drum.
When is a used wiper hazardous waste? The EPA wipes ruleBefore 2013 a shop towel with solvent on it was, in principle, a listed hazardous waste (F001 to F005 solvents). The 2013 rule added two conditional exclusions in 40 CFR 261.4. (b)(18), reusable wipes: wipes contaminated with solvent and sent to an industrial laundry or dry cleaner are not solid waste when they are accumulated, stored and transported in non-leaking closed containers labeled Excluded Solvent-Contaminated Wipes, held no more than 180 days from the start of accumulation, contain no free liquids when sent (the paint filter liquids test, Method 9095B, and free liquid removed to the container is managed as hazardous waste), and the laundry discharges to a permitted wastewater system; records are kept of the laundry, the container management and the 180 day timing. (a)(26), disposable wipes: the same conditions for wipes sent to a municipal landfill, hazardous waste landfill or combustor, except that wipes contaminated with trichloroethylene (TCE) are not eligible and go as hazardous waste. Wipes with hazardous metals, with other listed wastes, or with free liquid are outside the exclusion; a wipe with only used oil follows the used oil rules (40 CFR 279; the laundry or a used oil handler, not the landfill, in most states, and California treats used oil wipes under its own rules). The state program may be stricter (California adopted the rule in 2016 with modifications), so the generator checks DTSC or the state agency, and the laundry or hauler contract states what it accepts.
What about rags with paint, coolant, glue or food?Water-based paint, latex and water-based coolant on a rag: not flammable; trash or laundry by the maker’s SDS and the local rules (paint hardens; dried latex is trash in most jurisdictions). Oil-based paint, stains, lacquer thinner, acetone, mineral spirits, MEK: the oily waste can and the EPA wipes path. Adhesives and solvent cements (the adhesive guides): the solvent carrier decides; cyanoacrylate rags are trash once cured, contact cement rags are solvent rags. Grease, lube and gear oil: the oily waste can, then the used oil wiper path. Food, water and general soils: trash. Blood and body fluids: the regulated-waste bag, not the can (the biohazard guides). Lead paint dust, cadmium, chromate primer wipes: hazardous waste by the metal, with the dust rules on top. The SDS section 13 gives the maker’s disposal instruction and the label on the can says what it holds.
Dispensers and station setupJumbo roll floor stands and wall dispensers (the WypAll and Brawny jumbo rolls at 700 to 1,100 sheets), center-pull dispensers for one-hand feed, pop-up box holders, wall racks for brag boxes, bucket and tub dispensers for wet wipes, and a lint-free station at the paint and assembly benches; the oily waste can within reach of each station that produces the rags, a water bucket with a lid where finish rags are soaked, the hand cleaner and sink nearby, and the outdoor drum with a lid and a label for the daily empty. Counting: a 13 by 14 inch laundered towel is replaced by one X70 quarter-fold sheet in most tasks; the dispenser keeps the count down because a pulled sheet is one sheet.

In plain words

  • Laundered towels, cut rags or disposable nonwovens; the choice sets the waste path.
  • Finish and drying-oil rags self-heat in a pile and ignite; flat outdoors, under water in a sealed can, or in the listed oily waste can emptied daily.
  • The can: UL-listed steel, foot-pedal self-closing lid, raised bottom, 6 to 21 gallon, oily waste only.
  • OSHA 1910.106(e)(9) and 1926.252(e): covered metal containers, disposed of daily; the fire code: listed containers with self-closing lids.
  • EPA wipes rule: closed labeled container, no free liquid, 180 days, laundry or permitted landfill; TCE wipes and wipes with metals are hazardous waste.
  • Water-based and food soils are trash; solvent, oil and finish rags are never.

Questions people ask

Why do oily rags spontaneously combust?

Drying oils like linseed and oil-based stains give off heat as they cure; a pile traps the heat until the rags ignite.

What is an oily waste can required to have?

A UL listing, steel body, foot-pedal self-closing lid and an elevated bottom for air circulation; it is emptied daily.

Does OSHA require oily waste cans?

1910.106(e)(9)(iii) requires combustible waste in covered metal receptacles disposed of daily, and 1926.252(e) requires covered fire-resistant containers for oily rags on construction sites.

Are solvent shop towels hazardous waste?

Not if they meet the EPA 2013 wipes rule: closed labeled containers, no free liquid, 180 days, sent to a laundry or permitted landfill; TCE wipes and wipes with hazardous metals are hazardous waste.

What is the difference between WypAll X60 and X80?

The grade number is strength and absorbency; X60 is a general-purpose wiper and X80 a heavy-duty, reusable-within-a-shift wiper, as Kimberly-Clark rates them.

How should I dispose of stain rags at home or in a small shop?

Lay them flat outdoors to cure fully, or soak them in water in a sealed metal can, then dispose of them under the local rules; never in a pile, a bag or a box.

The ratings, test results and standards shown here are the manufacturers' published values, reproduced as published. Nothing on this page is a recommendation by Bayshore Safety that any product is suitable for a particular task, hazard or workplace. Selecting safety products and protective equipment is the responsibility of the end user and the employer, based on their own hazard assessment and the regulations that apply to their work. Confirm every value on the manufacturer's own documentation before use.

Stocking a shop, a plant or a jobsite with cleaning supplies?Call (925) 215-7337 or email us the can sizes, the floor type and the quantities and we will quote liners, mops, buckets, signs and wipers by the case with the part numbers listed. We sell nationwide.
All janitorial and hand hygiene guides

© 2026 Bayshore Safety & Industrial Supplies, Inc. All rights reserved. This guide may not be copied or republished without written permission.

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.