Description
The Dräger X-plore 1350 N95 Molded Disposable Respirators is a NIOSH 42 CFR 84 filtering facepiece (disposable) respirator. Versions: 3951351 X-plore 1350 XS N95; 3951352 X-plore 1350 S/M N95; 3951353 X-plore 1350 M/L N95; 3951358 X-plore 1350 V Odor S/M N95; 3951359 X-plore 1350 V Odor M/L N95; 3951355 X-plore 1350 V S/M N95; 3951356 X-plore 1350 V M/L N95. Ships in 1–2 business days; most orders arrive in 3–7 business days. X-plore 1300 and 1900 disposables on one page.
Versions
| Order no. | Model and size | NIOSH rating | Per box |
|---|---|---|---|
| 3951351 | X-plore 1350 XS | N95 | 20 |
| 3951352 | X-plore 1350 S/M | N95 | 20 |
| 3951353 | X-plore 1350 M/L | N95 | 20 |
| 3951358 | X-plore 1350 V Odor S/M | N95 | 10 |
| 3951359 | X-plore 1350 V Odor M/L | N95 | 10 |
| 3951355 | X-plore 1350 V S/M | N95 | 10 |
| 3951356 | X-plore 1350 V M/L | N95 | 10 |
Source: Dräger X-plore 1300 NIOSH product information (DMC-109830); Dräger Product Catalog, Industrial Applications (DMC-107423).
X-plore 1350 technical data
| Item | Manufacturer data |
|---|---|
| Intended | Protection against solid particles and liquid particles that do not contain oil |
| Standard | NIOSH 42 CFR Part 84: N95 (filtering facepieces) |
| Tc | TC-84A-4370 (X-plore 1350 N95 M/L) |
| Media | Combined electrically charged and mechanical filter media; several layers of non-woven materials |
| Strap | Natural rubber latex covered with woven textile (the latex does not contact the skin) |
| Noseclip | Plastic-coated metal wire, free of aluminium |
| Shelf | 4 years from production date; end of shelf life marked on the packaging |
| Weight | 13.3 g (M/L, excluding package) |
| Resist | Breathing resistance at 85 l/min: inhalation max. 3.5 mbar, exhalation max. 2.5 mbar (initial) |
| Pack | 20 per box |
Source: Dräger X-plore 1350 N95 M/L technical data sheet (T3951353-03).
NIOSH approvals naming the X-plore 1300 and 1900 series
The NIOSH Certified Equipment List carries 13 current Dräger approvals naming it: 13 air-purifying particulate (TC-84A). The first 12:
| Approval | Product line | For protection against | Facepiece |
|---|---|---|---|
| TC-84A-4370 | X-plore 1350, N95 Filtering Facepieces, part numbers 3951352 (S/M) and 3951353 (M/L). | N95 | Filtering Facepiece |
| TC-84A-4374 | Model X-plore 1350 N95 V, N95 Filtering Facepiece with Exhalation Valve, Part Numbers 3951355 and 3951356 | N95 | Filtering Facepiece |
| TC-84A-4375 | Model X-plore 1350 N95 V Odor, N95 Filtering Facepiece with exhalation valve, Part Numbers 3951358 and 3951359 | N95 | Filtering Facepiece |
| TC-84A-4396 | Model X-plore 1750 N95, part number 3951320, N95 Filtering Facepiece | N95 | Filtering Facepiece |
| TC-84A-4555 | Model X-plore 1750 N95 Filtering Facepiece with Exhalation Valve, Part Number 3951322 | N95 | Filtering Facepiece |
| TC-84A-4557 | Model X-plore 1750 N95 Filtering Facepiece with Exhalation Valve, Part Number 3951321 | N95 | Filtering Facepiece |
| TC-84A-5288 | Model X-plore 1350 N95 XS N95 Filtering Facepiece Respirator, Part Number 3951351 | N95 | Filtering Facepiece |
| TC-84A-7753 | Model X-plore 1750 CS N95 Filtering Facepiece Air Purifying Respirator | N95 | Filtering Facepiece |
| TC-84A-9044 | X-plore 1900 Series, M/L N95 Filtering Facepiece | N95 | Filtering Facepiece |
| TC-84A-9045 | X-plore 1900 Series Small N95 Filtering Facepiece | N95 | Filtering Facepiece |
| TC-84A-9046 | X-plore 1900 Series, M/L N95 Filtering Facepiece with Exhalation Valve | N95 | Filtering Facepiece |
| TC-84A-9047 | X-plore 1900 Series Small N95 Filtering Facepiece with Exhalation Valve | N95 | Filtering Facepiece |
Source: NIOSH Certified Equipment List (October 2026), manufacturer Dräger Safety AG & Co. KGaA.
Assigned protection factor
| Respirator type (OSHA Table 1) | APF |
|---|---|
| Filtering facepiece (air-purifying half mask) | 10 |
Source: OSHA 29 CFR 1910.134 Table 1 (Assigned Protection Factors). The APF applies only when the respirator is used in a program that meets the standard, including fit testing of tight-fitting facepieces (29 CFR 1910.134(f)) and a cartridge change schedule (29 CFR 1910.134(d)(3)(iii)).
Catalog data
| Item | Manufacturer data |
|---|---|
| Standards | NIOSH 42 CFR 84 |
| Size | XS; S/M; M/L |
| Style | Molded; Molded, valved |
| Filter Class | N95 |
Source: Manufacturer published product data as carried in our catalog.
The Draeger X-plore 1350 is a NIOSH N95 molded disposable respirator for fine dust and non-oil particles. The filter media holds up to heavy dust while keeping breathing resistance low, and a continuous loop harness with tension adjuster makes fitting quick.
- NIOSH 42 CFR 84 approved, N95 (min. 95% efficiency, non-oil)
- Continuous loop head harness with strap tension adjuster
- Valved version has a CoolMAX exhalation valve
- Odor version adds an activated carbon layer for nuisance organic odors
- Single-shift use
Draeger part number: select an option to see the exact part number.
Available in 7 versions:
- Standard, case of 240 / XS – 3951351
- Standard, case of 240 / S/M – 3951352
- Valved Odor, case of 180 / S/M – 3951358
- Valved, case of 180 / S/M – 3951355
- Standard, case of 240 / M/L – 3951353
- Valved Odor, case of 180 / M/L – 3951359
- Valved, case of 180 / M/L – 3951356
Dräger X-plore questions
What does an N95 filtering facepiece protect against? Protection against solid particles and liquid particles that do not contain oil (X-plore 1350 technical data sheet).
What is the shelf life? 4 years from production date; end of shelf life marked on the packaging (X-plore 1350 technical data sheet).
Guides: P100 vs N95 vs R95 · N95 shelf life and reuse · Draeger X-plore filter codes · X-plore 3300 vs 3500 vs 5500 · PAPR vs air-purifying respirators · all North and Draeger respirators by model and hazard.