Description
The Dräger X-plore 3500 is a half mask with two Dräger bayonet connections (twin-filter) for X-plore Bayonet filters. Versions: R55351 (S), R55350 (M), R55352 (L). Mask body drägerflex material, black; sizes S, M, L. Ships in 1–2 business days; most orders arrive in 3–7 business days. X-plore 3500: every filter, part and NIOSH approval on one page.
Dräger X-plore 3500 specifications
| Item | Manufacturer data |
|---|---|
| Mask type | Half mask |
| Mask body | DrägerFlex material, black |
| Sizes | S, M, L |
| Versions | R55351 (S), R55350 (M), R55352 (L) |
| Filter connection | Two Dräger bayonet connections (twin-filter) for X-plore Bayonet filters |
| Weight | approx. 3.35 oz (95 g) |
| Packaging | 16 / box |
| Approvals | NIOSH |
| Note | Drop-down strap design: the mask can be removed by releasing the fastener at the neck. |
Source: Dräger X-plore 3500/3300 Half Mask product information (DMC-109820).
X-plore Bayonet filters for this mask
The bayonet filter sheet states all X-plore Bayonet filters and cartridges are NIOSH approved with the full range of X-plore half and full face masks (3300, 3500, 5500); the gas cartridges can be upgraded to combination cartridges with the pad attachments or the X-plore Pure with an adapter. OV = Organic Vapors, AG = Acid Gases, CL = Chlorine, HC = Hydrogen Chloride, SD = Sulfur Dioxide, HF = Hydrogen Fluoride, FM = Formaldehyde, CD = Chlorine Dioxide, AM = Ammonia, MA = Methylamine, HS = Hydrogen Sulfide, PH = Phosphine (Dräger filter color-code key).
| Order no. | Type | Filter code | Packing unit |
|---|---|---|---|
| 6740830 | Particle filter | P100 Bayonet | 22 pcs = 11 pairs |
| 6738350 | Particle filter | Pure P100 | 20 pcs = 10 pairs |
| 6738392 | Particle filter | Pure P100 Odor (P100 with nuisance OV/AG odor relief) | 20 pcs = 10 pairs |
| 6738020 | Particle filter pad | N95 pad | 20 pcs |
| 6738021 | Particle filter pad | R95 pad | 20 pcs |
| 6738024 | Gas filter | OV | 20 pcs = 10 pairs |
| 6738027 | Gas filter | AM/MA | 20 pcs = 10 pairs |
| 6738025 | Gas filter | OV/AG/HF/FM/CD | 20 pcs = 10 pairs |
| 6738351 | Gas filter | Multi-Gas+ (OV/AG/HF/FM/CD/AM/MA/HS) | 20 pcs = 10 pairs |
| 6738034 | Combination filter | OV/P100 | 14 pcs = 7 pairs |
| 6738037 | Combination filter | AM/MA/P100 | 14 pcs = 7 pairs |
| 6738035 | Combination filter | OV/AG/HF/FM/CD/P100 | 14 pcs = 7 pairs |
| 6738361 | Combination filter | Multi-Gas+/P100 (OV/AG/HF/FM/CD/AM/MA/HS/P100) | 14 pcs = 7 pairs |
| 6738356 | Accessory | Pure Adapter (for use with gas filters to combine with Pure P100) | 10 pcs |
| 6738038 | Accessory | Filter Pad Retainer | 12 pcs |
| 6738039 | Accessory | Filter Pad Base | 12 pcs |
Source: Dräger X-plore Bayonet Filters NIOSH product information (DMC-109824).
Assigned protection factor
| Respirator type (OSHA Table 1) | APF |
|---|---|
| Air-purifying half mask | 10 |
Source: OSHA 29 CFR 1910.134 Table 1 (Assigned Protection Factors). The APF applies only when the respirator is used in a program that meets the standard, including fit testing of tight-fitting facepieces (29 CFR 1910.134(f)) and a cartridge change schedule (29 CFR 1910.134(d)(3)(iii)).
Catalog data
| Item | Manufacturer data |
|---|---|
| Standards | NIOSH 42 CFR 84 |
| Sizes | S, M and L |
Source: Manufacturer published product data as carried in our catalog.
Reusable NIOSH-approved half mask with a soft face seal and Flexi-Fit harness for long-wear comfort, taking Draeger X-plore bayonet filters and cartridges.
- NIOSH-approved reusable half facepiece
- Flexi-Fit head harness
- Swept-back design fits under face shields
- Uses X-plore bayonet filters and cartridges (sold separately)
Manufacturer item number: see the list below. Select a version to see the exact item number.
Available in 2 versions:
- M – R55350
- L – R55352
Dräger X-plore 3500 questions
What filters fit the Dräger X-plore 3500? X-plore Bayonet filters (two bayonet connections); all bayonet filters are NIOSH approved with the X-plore half and full face masks (bayonet filter sheet).
What sizes does the X-plore 3500 come in? S, M, L.
What is the X-plore 3500 made of? DrägerFlex material, black.
Is the X-plore 3500 NIOSH approved? NIOSH.
Guides: Draeger X-plore filter codes · X-plore 3300 vs 3500 vs 5500 · PAPR vs air-purifying respirators · half mask vs full facepiece · assigned protection factors · what OSHA requires for fit testing · cleaning and storing respirators · all North and Draeger respirators by model and hazard.