Description
The Dräger 3729120 is the X-plore 8000 PAPR helmet with visor for the X-plore 8000 powered air-purifying respirator. Ships in 1–2 business days; most orders arrive in 3–7 business days. X-plore 8000 PAPR: every filter, headpiece, part and NIOSH approval on one page.
Dräger 3729120 specifications
| Item | Manufacturer data |
|---|---|
| Part numbers | 3729120, 3710775, 3710790, 3710780, 3710795, 3710785 |
| System | Dräger X-plore 8000 PAPR |
| 3729120 | X-plore 8000 Helmet PC visor HL1 |
| 3710775 | X-plore 8000 Helmet PC visor L1Z |
| 3710790 | X-plore 8000 Helmet PC visor L2T2 |
| 3710780 | X-plore 8000 Helmet PC visor L2Z |
| 3710795 | X-plore 8000 Helmet PC visor L3T4 |
| 3710785 | X-plore 8000 Helmet PC visor L3Z |
Source: Dräger Product Catalog, Industrial Applications (DMC-107423); Dräger X-plore 8000 product information (DMC-102510).
X-plore 8000 helmet and headpiece technical data
| Item | Manufacturer data |
|---|---|
| Visor | PC (helmet with visor); PETG (helmet-hood and bump-cap-hood combinations) |
| Seal | Zytec FR (helmet seal) or Tychem 2000 / Tychem 4000 (hood) |
| Helmet | PA shell, ABS visor frame |
| Visor size | 10.2 x 6.6 in. (helmet with visor); 11.8 x 9 in. (hood combinations) |
| Temp | 23 to 122 F (operation) |
| Harness | Ratchet, adjustable 8.3 to 9.4 in. |
| Weight | L1Z 2 lbs; L2Z 2.2 lbs; L2T2 2.1 lbs; helmet with hood T2 1.7 lbs; bump cap with hood T2 1.5 lbs |
Source: Dräger Product Catalog, Industrial Applications (DMC-107423), X-plore 8000 helmets technical data.
X-plore 8000 system data
| Item | Manufacturer data |
|---|---|
| Blower units | R59500 X-plore 8500 (IP) blower unit, IP65, R59550 X-plore 8700 (EX) blower unit, intrinsically safe (Class I, Zone 1, AEx ib IIB T4 Gb) |
| Airflow | Automatic setting by headpiece type; adjustable in three levels: full-face mask 115, 130 or 145 l/min; hoods and helmets 170, 190 or 210 l/min |
| Battery | Lithium-ion 10.8 V / 6.8 Ah (high-capacity battery); operating time 8 to 20 hours depending on flow and contaminant load; charging 4 hours (80% in 2 hours) |
| Weight | X-plore 8500 with standard battery and splash guard lid approx. 3 lbs; X-plore 8700 approx. 3.3 lbs |
| Alarms | Optical, acoustical (at least 80 dB(A) at 3.3 ft) and vibration alarm |
| Belt | Adjustable 27.5 in. to 55 in. (standard and decontamination belts); belt extension 13.8 in. |
| Approval | NIOSH 42 CFR 84 with X-plore 8000 hoods, helmets, X-plore 6000 and FPS 7000 full-face masks |
| Note | Standard long hoods, the disposable hose cover and the welding visor must not be used in potentially explosive atmospheres (pi8000). |
Source: Dräger X-plore 8000 product information (DMC-102510).
NIOSH approvals naming this part
The NIOSH Certified Equipment List carries 22 current Dräger approvals naming it: 2 powered air-purifying (TC-21C), 20 chemical cartridge (TC-23C). The first 12:
| Approval | Product line | For protection against | Facepiece |
|---|---|---|---|
| TC-21C-1419 | X-plore 8500 PAPR, w/3729120 X-plore 8000 HL1 Helmet and 6739540 HE Filter | High-Efficiency | Helmet |
| TC-21C-1420 | X-plore 8700 PAPR, w/3729120 X-plore 8000 HL1 Helmet and 6739540 HE Filter | High-Efficiency | Helmet |
| TC-23C-3772 | 3710775, 3710780, or 3710790 w/ 6739560 Filter Cartridge, X-plore 8000 series PAPR system (Helmet) w/combination filter | HEPA (PAPR only), Organic Vapor | Helmet |
| TC-23C-3773 | 3710775, 3710780, or 3710790 w/ 6739590 Cartridge, X-plore 8000 series PAPR system (Helmet) w/ cartridge | Ammonia, Chlorine, Formaldehyde, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, M | Helmet |
| TC-23C-3774 | 3710775, 3710780, or 3710790 w/ 6739575 Cartridge, X-plore 8000 series PAPR system (Helmet) w/ cartridge | Organic Vapor | Helmet |
| TC-23C-3775 | 3710775, 3710780, or 3710790 w/ 6739570 Filter Cartridge, X-plore 8000 series PAPR system (Helmet) w/combination filter | Ammonia, Chlorine, Formaldehyde, HEPA (PAPR only), Hydrogen Chloride, Hydrogen Fluoride, H | Helmet |
| TC-23C-3776 | 3710775, 3710780, or 3710790 w/ 6739565 Filter Cartridge, X-plore 8000 series PAPR system (Helmet) w/combination filter | Chlorine, HEPA (PAPR only), Hydrogen Chloride, Organic Vapor, Sulfur Dioxide | Helmet |
| TC-23C-3777 | 3710785 or 3710795 w/ 6739560 Filter Cartridge, X-plore 8000 series PAPR system (Helmet) w/combination filter cartridge | HEPA (PAPR only), Organic Vapor | Helmet |
| TC-23C-3778 | 3710785 or 3710795 w/ 6739590 Cartridge, X-plore 8000 series PAPR system (Helmet) w/ cartridge | Ammonia, Chlorine, Formaldehyde, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, M | Helmet |
| TC-23C-3779 | 3710785 or 3710795 w/ 6739575 Cartridge, X-plore 8000 series PAPR system (Helmet) w/ cartridge | Organic Vapor | Helmet |
| TC-23C-3780 | 3710785 or 3710795 w/ 6739570 Filter Cartridge, X-plore 8000 series PAPR system (Helmet) w/combination filter cartridge | Ammonia, Chlorine, Formaldehyde, HEPA (PAPR only), Hydrogen Chloride, Hydrogen Fluoride, H | Helmet |
| TC-23C-3781 | 3710785 or 3710795 w/ 6739565 Filter Cartridge, X-plore 8000 series PAPR system (Helmet) w/combination filter cartridge | Chlorine, HEPA (PAPR only), Hydrogen Chloride, Organic Vapor, Sulfur Dioxide | Helmet |
Source: NIOSH Certified Equipment List (October 2026), manufacturer Dräger Safety AG & Co. KGaA.
Assigned protection factor
| Respirator type (OSHA Table 1) | APF |
|---|---|
| Powered air-purifying helmet/hood (manufacturer-tested to APF 1,000) | 1000 |
| Powered air-purifying loose-fitting facepiece | 25 |
| Powered air-purifying full facepiece | 1000 |
Source: OSHA 29 CFR 1910.134 Table 1 (Assigned Protection Factors). The APF applies only when the respirator is used in a program that meets the standard, including fit testing of tight-fitting facepieces (29 CFR 1910.134(f)) and a cartridge change schedule (29 CFR 1910.134(d)(3)(iii)).
Catalog data
| Item | Manufacturer data |
|---|---|
| Style | Chin seal; Neck seal; Shoulder seal |
| Material | Zytec FR; Tychem 2000; Tychem 4000 |
Source: Manufacturer published product data as carried in our catalog.
Draeger X-plore 8000 PAPR helmets with integrated head, eye and face protection and a flip-up polycarbonate visor. Choose the seal length and material: chin, neck or shoulder seal in flame resistant Zytec FR or chemical resistant Tychem.
- Flip-up polycarbonate visor
- Chin (L1), neck (L2) or shoulder (L3) seal
- Zytec FR or Tychem 2000/4000 seal material
- Head, eye and face protection in one headpiece
- For X-plore 8500 and 8700 PAPR
Draeger part number: select an option to see the exact part number.
Available in 6 versions:
- HL1 – 3729120
- L1Z: chin seal, Zytec FR – 3710775
- L2T2: neck seal, Tychem 2000 – 3710790
- L2Z: neck seal, Zytec FR – 3710780
- L3T4: shoulder seal, Tychem 4000 – 3710795
- L3Z: shoulder seal, Zytec FR – 3710785
Dräger 3729120 questions
What PAPR does the 3729120 fit? The Dräger X-plore 8000 system (X-plore 8500 and 8700 blowers).
How long does the X-plore 8000 run on a charge? Lithium-ion 10.8 V / 6.8 Ah (high-capacity battery); operating time 8 to 20 hours depending on flow and contaminant load; charging 4 hours (80% in 2 hours).
Guides: Draeger X-plore filter codes · X-plore 3300 vs 3500 vs 5500 · PAPR vs air-purifying respirators · half mask vs full facepiece · assigned protection factors · what OSHA requires for fit testing · cleaning and storing respirators · all North and Draeger respirators by model and hazard.