Fit Testing
15 fit testing from every brand we carry, listed with what each manufacturer publishes.
Pick a brand, filter class, respirator type or size; the list below narrows as you choose.

15 products
Ratings and specifications are as published by each manufacturer. Tap a group to open it.
3M5 products
- 3M 601 Respirator Fit Testing, Fit Test Adapter — 3M
- 3M FT-11 Respirator Fit Testing, Sensitivity Solution, Sweet — 3M · Fits / series: 3M FT-10 Qualitative Fit Test Apparatus (sweet)
- 3M FT-12 Respirator Fit Testing, Fit Test Solution, Sweet — 3M
- 3M Respirator Fit Testing, Qualitative Fit Test Apparatus, FT-10 — 3M
- 3M Respirator Fit Testing, Respirator Accessories, FT-14 — 3M
North5 products
Draeger4 products
- Draeger 4055625 Bitrex Qualitative Fit Test Kit, Complete — Draeger · Standards: Bitrex taste test
- Draeger Bitrex Fit Test Kit Replacement Parts (Nebulizer, Hood) — Draeger · Standards: Bitrex taste test
- Draeger Bitrex Fit Test Solutions, 6 Ampules — Draeger · Standards: Bitrex taste test
- Draeger Quantitative Fit Test Adapters for X-plore and FPS Masks — Draeger · Standards: Quantitative fit testing
Allegro1 product
- Allegro 2041 Respirator Fit Testing, Bitrex Fit Test Kits — Allegro · Fits / series: Replacement solutions: 2041-11K sensitivity (6/box); 2041-12K test (6/box) · Standards: Qualitative OSHA-compliant fit testing (bitter, denatonium benzoate)
Do not see what you need? Browse the category or call (925) 215-7337.
NIOSH approves respirators and filters under 42 CFR Part 84 and marks each one with a filter class: the letter is oil resistance (N not resistant to oil, R resistant for a shift, P oil proof) and the number is the filtration efficiency in the test (95, 99 or 100 percent). Cartridges for gases and vapours are colour-coded by the contaminant (organic vapour, acid gas, ammonia and so on) and fit only the facepiece series the manufacturer lists them for. Supplied-air and powered-air systems carry their own NIOSH approval as a complete assembly.
Technical. 42 CFR Part 84 filter classes N95, N99, N100, R95, R99, R100, P95, P99, P100; each approved product carries a TC-84A- (particulate), TC-23C- (gas/vapour), TC-21C- (PAPR), TC-19C- (supplied air) or TC-13F- (SCBA) approval number, printed by the manufacturer. OSHA 29 CFR 1910.134 requires a written program, medical evaluation and fit testing (qualitative or quantitative) for tight-fitting respirators. Cartridge-to-facepiece fit is as published by each manufacturer; the manufacturer's approval label lists the exact assemblies approved together.
The ratings, test results and standards shown here are the manufacturers' published values, reproduced as published. Nothing on this page is a recommendation by Bayshore Safety that any product is suitable for a particular task, hazard or workplace. Selecting safety products and protective equipment is the responsibility of the end user and the employer, based on their own hazard assessment and the regulations that apply to their work. Confirm every value on the manufacturer's own documentation before use.
The standard at a glance
Copied from the named standard or regulation and shown with its source; nothing in these tables is Bayshore's recommendation.
NIOSH filter classes (42 CFR Part 84)
| Class | Oil resistance | Filter efficiency in the NIOSH test |
|---|---|---|
| N95 | Not resistant to oil | 95% |
| N99 | Not resistant to oil | 99% |
| N100 | Not resistant to oil | 99.97% |
| R95 | Resistant to oil (one shift) | 95% |
| R99 | Resistant to oil (one shift) | 99% |
| R100 | Resistant to oil (one shift) | 99.97% |
| P95 | Oil proof | 95% |
| P99 | Oil proof | 99% |
| P100 | Oil proof | 99.97% |
| Approval number prefix | Respirator class |
|---|---|
| TC-84A- | Particulate filters and filtering facepieces |
| TC-23C- | Gas and vapour cartridges and canisters |
| TC-21C- | Powered air-purifying respirators (PAPR) |
| TC-19C- | Supplied-air respirators |
| TC-13F- | Self-contained breathing apparatus (SCBA) |
Source: NIOSH, 42 CFR Part 84 (Approval of Respiratory Protective Devices). Fit testing and medical evaluation: OSHA 29 CFR 1910.134.