Respirators for Pesticides
Pesticide application (organic vapor and particulate): the exposure limits, the OSHA and Cal/OSHA rule paragraphs as written, and the North and Dräger respirators, cartridges and filters whose own published data lists the hazard, with live prices. We sell nationwide; ships in 1–2 business days; most orders arrive in 3–7 business days.
The exposure limits
| Source | Limit |
|---|---|
| OSHA Table Z-1 (29 CFR 1910.1000) | Malathion 15 mg/m³ (skin); pyrethrum 5 mg/m³; pentachlorophenol 0.5 mg/m³ (skin); others as listed |
| EPA Worker Protection Standard (40 CFR part 170) | The pesticide product label specifies the respirator; under the WPS the label's PPE statement governs, with NIOSH-approved respirators and fit testing, medical evaluation and training requirements referenced in 40 CFR 170.507 |
What the federal rule says
Each entry is condensed from the paragraph cited; the paragraph itself is the rule and the link opens it.
29 CFR 1910.134(d)(3)(iii)(B): For gases and vapors: an atmosphere-supplying respirator, or an air-purifying respirator with a NIOSH-certified ESLI for the contaminant, or a cartridge change schedule based on objective data.
Source: 29 CFR, Occupational Safety and Health Standards, as published by OSHA (ecfr.gov / osha.gov), read Nov 2–3 2026.
California (Cal/OSHA)
Each entry is condensed from the paragraph cited; the paragraph itself is the rule and the link opens it.
Title 8 §5144 and Title 3 (DPR): California applies §5144 and the Department of Pesticide Regulation's worker safety rules; the label's respirator statement governs.
Source: California Code of Regulations, Title 8, as published by Cal/OSHA (dir.ca.gov), read Nov 2–3 2026.
What the makers' data lists for pesticide application
Dräger's selection guide lists specific pesticide compounds by CAS number with its OV, OV/P100 and Multi-Gas+ filters (the entries that matched are listed below). The North chart lists organic vapor cartridges and the P100 combinations. The label's respirator statement is the controlling source for each product.
North cartridges and filters whose chart entry covers it
| Part number | Item | Version | Price | |
|---|---|---|---|---|
| N75001L | North N75001L Organic Vapor (OV) Cartridge Organic Vapor; label Black | $15.49 | ||
| N75003L | North N75003L Organic Vapor and Acid Gas (OV/AG) Cartridge Organic Vapor and Acid Gas (Chlorine, Hydrogen Chloride, Sulfur Dioxide, Hydrogen Fluoride, Hydrogen Sulfide, Chlorine D; label Yellow | $16.49 | ||
| 75SCL | North 75SCL Defender Multi-Gas Vapor Cartridge Organic Vapor, Ammonia, Methylamine, Formaldehyde and Acid Gas (Chlorine, Hydrogen Chloride, Sulfur Dioxide, Hydrogen Su; label Olive | $16.99 | ||
| 7581P100L | North 7581P100L Organic Vapor (OV) Cartridge with P100 Filter Organic Vapor, with a P100 particulate filter (99.97% minimum filter efficiency) for all particulates; label Black and Magenta | $25.49 | ||
| 7583P100L | North 7583P100L Organic Vapor and Acid Gas (OV/AG) Cartridge with P100 Filter Organic Vapor and Acid Gas (Chlorine, Hydrogen Chloride, Sulfur Dioxide, Hydrogen Fluoride, Hydrogen Sulfide, Chlorine D; label Yellow and Magenta | $26.99 | ||
| 75SCP100L | North 75SCP100L Defender Multi-Contaminant Cartridge with P100 Filter Organic Vapor, Ammonia, Methylamine, Formaldehyde and Acid Gas (Chlorine, Hydrogen Chloride, Sulfur Dioxide, Hydrogen Su; label Olive and Magenta | $30.99 | ||
| 7580P100 | North 7580P100 P100 Filters, Pack of 2 P100 particulate filter (99.97% minimum filter efficiency) for all particulates; label Magenta | $8.91 | ||
| 75FFP100 | North 75FFP100 Flexible Low-Profile P100 Filters, Pack of 2 Low profile P100 particulate filter (99.97% minimum filter efficiency) for all particulates; label Magenta | $8.29 | ||
| 75FFP100NL | North 75FFP100NL Flexible Low-Profile P100 Filters with Odor Relief, Pack of 2 Low profile P100 particulate filter (99.97% minimum filter efficiency) for all particulates; with odor relief from nuisa; label Magenta | $12.99 | ||
| 7582P100L | North 7582P100L Acid Gas (AG) Cartridge with P100 Filter Acid Gas (Chlorine, Hydrogen Chloride, Sulfur Dioxide, Hydrogen Fluoride, Chlorine Dioxide) and Formaldehyde, with a P10; label White and Magenta | $31.49 | ||
| 7584P100L | North 7584P100L Ammonia and Methylamine Cartridge with P100 Filter Ammonia and Methylamine, with a P100 particulate filter (99.97% minimum filter efficiency) for all particulates; label Green and Magenta | $32.99 | ||
| 75852P100L | North 75852P100L Mercury Vapor and Chlorine Cartridge with ESLI and P100 Filter Mercury Vapor and Chlorine, with End-of-Service-Life Indicator (ESLI) for Mercury Vapor, with a P100 particulate filter ; label Olive and Magenta | $64.99 | ||
| 7586P100L | North 7586P100L Nitrogen Dioxide Cartridge with P100 Filter Nitrogen Dioxide, with a P100 particulate filter; label — | $43.99 |
Source: North Cartridge & Filter Reference Chart; NIOSH approval labels (PIP).
North facepieces
Source: North product sheets (PIP).
Dräger filters listed for it
| Part number | Item | Version | Price | |
|---|---|---|---|---|
| 6739565 | Draeger 6739565 X-plore 8000 PAPR OV/AG/HE Combination Filter, Pack Combination filter OV/AG/HE; selection guide lists it for Endrin (ISO), Magnesium oxide fume Malathion (ISO), Parathion (ISO), Pentachlorophenol | $475.16 | ||
| 6738034 | Draeger 6738034 X-plore Bayonet Combination Filter OV/P100, Pack of 14 Combination filter OV/P100; selection guide lists it for Endrin (ISO), Lindane, Magnesium oxide fume Malathion (ISO), Parathion (ISO)… | $184.96 | ||
| 6738035 | Draeger 6738035 X-plore Bayonet Combination Filter OV/AG/FM/CD/HF/P100, Pack of 14 Combination filter OV/AG/HF/FM/CD/P100; selection guide lists it for Endrin (ISO), Lindane, Magnesium oxide fume Malathion (ISO), Parathion (ISO)… | $206.09 | ||
| 6738361 | Draeger 6738361 X-plore Bayonet Combination Filter OV/AG/HF/FM/CD/AM/MA/HS/P100, Pack of 14 Combination filter Multi-Gas+/P100 (OV/AG/HF/FM/CD/AM/MA/HS/P100); selection guide lists it for Endrin (ISO), Lindane, Magnesium oxide fume Malathion (ISO), Parathion (ISO)… | $261.39 | ||
| 6739560 | Draeger 6739560 X-plore 8000 PAPR OV/HE Combination Filter, Pack Combination filter OV/HE; selection guide lists it for Endrin (ISO), Magnesium oxide fume Malathion (ISO), Parathion (ISO), Pentachlorophenol | $478.60 | ||
| 6739540 | Draeger 6739540 X-plore 8000 PAPR HE Particle Filter, Pack Particulate filter HE; selection guide lists it for Magnesium oxide fume Malathion (ISO) | $208.73 | ||
| 6740830 | Draeger 6740830 X-plore Bayonet P100 Particle Filter, Pack of 22 (11 Pairs) Particle filter P100 Bayonet | $146.57 | ||
| 6738350 | Draeger 6738350 X-plore Pure P100 Flat Particle Filter, Pack of 20 (10 Pairs) Particle filter Pure P100 | $76.62 | ||
| 6738392 | Draeger 6738392 X-plore Pure Odor P100 OV/AG Filter Particle filter Pure P100 Odor (P100 with nuisance OV/AG odor relief) | $9.74 | ||
| 6738037 | Draeger 6738037 X-plore Bayonet Combination Filter AM/MA/P100, Pack of 14 Combination filter AM/MA/P100 | $200.96 | ||
| 6737013 | Draeger 6737013 Rd40 P100 Particle Filter for Full Face Masks, NIOSH Particle filter P100 | $230.78 | ||
| 6737360 | Draeger 6737360 Rd40 PH/CN/CS/P100 Canister for Full Face Masks, NIOSH Canister Phosphine/Tear Gas/P100 (PH/CN/CS/P100) | $464.56 | ||
| 6739570 | Draeger 6739570 X-plore 8000 PAPR MultiGas/HE Combination Filter, Pack Combination filter MultiGas HE (CL/HF/AM/MA/FM/HS/SD/HC/HE) | $529.49 |
Source: Dräger Guide for Selection and Use of Respiratory Filtering Devices, NIOSH (DMC-104642); Dräger X-plore Bayonet Filters NIOSH product information (DMC-109824); Dräger X-plore 8000 product information (DMC-102510).
Dräger masks
Source: Dräger Product Catalog, Industrial Applications (DMC-107423).
Dräger X-plore 8000 PAPR blowers
| Part number | Item | Version | Price | |
|---|---|---|---|---|
| R59500 | Draeger R59500 X-plore 8500 (IP) PAPR Blower Unit | $762.01 | ||
| R59550 | Draeger R59550 X-plore 8700 (EX) PAPR Blower Unit | $1259.70 |
Source: Dräger X-plore 8000 product information (DMC-102510).
Dräger selection guide entries
5 entries in the Dräger respiratory selection guide match pesticide application; each names the filters by part number.
| Substance | CAS | Dräger filter part numbers |
|---|---|---|
| Endrin (ISO) | 72-20-8 | 6739565, 6738034, 6738035, 6738361, 6739560 |
| Lindane | 58-89-9 | 6738034, 6738035, 6738361 |
| Magnesium oxide fume Malathion (ISO) | 121-75-5 | 6739540, 6739565, 6738034, 6738035, 6738361, 6739560 |
| Parathion (ISO) | 56-38-2 | 6739565, 6738034, 6738035, 6738361, 6739560 |
| Pentachlorophenol | 87-86-5 | 6739565, 6738034, 6738035, 6738361, 6739560 |
Source: Dräger Respiratory Protection Selection Guide (PIP document library).
Assigned protection factor
| Respirator type (OSHA Table 1) | APF |
|---|---|
| Air-purifying half mask | 10 |
| Air-purifying full facepiece | 50 |
| Powered air-purifying half mask | 50 |
| Powered air-purifying full facepiece | 1000 |
| Powered air-purifying helmet/hood (manufacturer-tested to APF 1,000) | 1000 |
Source: OSHA 29 CFR 1910.134 Table 1 (Assigned Protection Factors). The APF applies only when the respirator is used in a program that meets the standard, including fit testing of tight-fitting facepieces (29 CFR 1910.134(f)) and a cartridge change schedule (29 CFR 1910.134(d)(3)(iii)).
Guides: half mask vs full facepiece · assigned protection factors · cartridge change schedules · P100 vs N95 vs R95 · what OSHA requires for fit testing · cleaning and storing respirators.
Respirators for Pesticides questions
What respirator does a pesticide label require? The label's personal protective equipment statement, which the EPA Worker Protection Standard makes mandatory; it names the NIOSH approval type (for example an organic-vapor cartridge with a particulate prefilter, or a particulate respirator).
What cartridge type do the makers list for pesticides? Organic vapor (OV) and OV with P100 on the North chart; Dräger lists OV, OV/P100 and Multi-Gas+ filters against the compounds in its selection guide.