Skip to main content
Draeger detector tubes · Acetaldehyde

Draeger Acetaldehyde Detector Tubes

1 Draeger short-term detector tube for Acetaldehyde, measuring range 100 to 1000 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (p. 118); prices are live. Ships in 1–2 business days.

Every Draeger tube for Acetaldehyde

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
6726665Draeger Acetaldehyde 100/a Detector Tubes, Box of 10100 to 1000 ppm20approx. 5 minorange → brown-greenBox of 10$107.41

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 118, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Acetaldehyde exposure limits

LimitValue
OSHA PELTWA 200 ppm (360 mg/m³)
NIOSH RELCa (Aldehydes)
NIOSH IDLHCa [2000 ppm]
CAS number75-07-0
FormulaCH₃CHO
Other namesAcetic aldehyde, Ethanal, Ethyl aldehyde
Conversion1 ppm = 1.80 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Acetaldehyde (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless liquid or gas (above 69°F) with a pungent, fruity odor.

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Acetaldehyde tube questions

Which Draeger tubes measure Acetaldehyde? 6726665 (100 to 1000 ppm).

What is the lowest range Draeger tube for Acetaldehyde? 6726665, 100 to 1000 ppm, 20 strokes.

What is the OSHA exposure limit for Acetaldehyde? OSHA PEL TWA 200 ppm (360 mg/m³); NIOSH REL Ca (Aldehydes); IDLH Ca [2000 ppm] (NIOSH Pocket Guide).

Which pump reads Draeger Acetaldehyde tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Acetaldehyde tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.