Draeger Acetic Acid Detector Tubes

1 Draeger short-term detector tube for Acetic acid, measuring range 5 to 80 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (p. 119); prices are live. Ships in 1–2 business days.

Every Draeger tube for Acetic acid

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
6722101Draeger Acetic Acid 5/a Detector Tubes, Box of 105 to 80 ppm3approx. 30 sviolet-blue → yellowBox of 10$107.30

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 119, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Acetic acid exposure limits

LimitValue
OSHA PELTWA 10 ppm (25 mg/m³)
NIOSH RELTWA 10 ppm (25 mg/m³) ST 15 ppm (37 mg/m³)
NIOSH IDLH50 ppm
CAS number64-19-7
FormulaCH₃COOH
Other namesAcetic acid (aqueous), Ethanoic acid, Glacial acetic acid, Methanecarboxylic acid [Note: Can be found in concentrations of 5-8% in vinegar.]
Conversion1 ppm = 2.46 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Acetic acid (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless liquid or crystals with a sour, vinegar-like odor. [Note: Pure compound is a solid below 62°F. Often used in an aqueous solution.]

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Acetic acid tube questions

Which Draeger tubes measure Acetic acid? 6722101 (5 to 80 ppm).

What is the lowest range Draeger tube for Acetic acid? 6722101, 5 to 80 ppm, 3 strokes.

What is the OSHA exposure limit for Acetic acid? OSHA PEL TWA 10 ppm (25 mg/m³); NIOSH REL TWA 10 ppm (25 mg/m³) ST 15 ppm (37 mg/m³); IDLH 50 ppm (NIOSH Pocket Guide).

Which pump reads Draeger Acetic acid tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Acetic acid tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.