Skip to main content

Draeger Alcohol Detector Tubes

1 Draeger short-term detector tube for Alcohol, measuring range 500 - 5000 ppm / 10 - 500 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (p. 124); prices are live. Ships in 1–2 business days.

Every Draeger tube for Alcohol

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
3740290Draeger Alcohol 10/a Detector Tubes, Box of 10500 - 5000 ppm / 10 - 500 ppm2 / 53 min / 7.5 minyellow → mint greenBox of 10$115.84

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 124, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Draeger MicroTubes for Alcohol (X-act 7000)

MicroTubeMeasuring rangePrice
Draeger Alcohol MicroTube for X-act 7000, 10-5000 ppm10-5000 ppm$130.68

MicroTubes are read electronically on the Draeger X-act 7000, not on a hand pump.

Alcohol exposure limits

LimitValue
OSHA PELTWA 1000 ppm (1900 mg/m³)
NIOSH RELTWA 1000 ppm (1900 mg/m³)
NIOSH IDLH3300 ppm [10%LEL]
CAS number64-17-5
FormulaCH₃CH₂OH
Other namesAlcohol, Cologne spirit, Ethanol, EtOH, Grain alcohol
Conversion1 ppm = 1.89 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Ethyl alcohol (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Clear, colorless liquid with a weak, ethereal, vinous odor.

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Alcohol tube questions

Which Draeger tubes measure Alcohol? 3740290 (500 - 5000 ppm / 10 - 500 ppm).

What is the lowest range Draeger tube for Alcohol? 3740290, 500 - 5000 ppm / 10 - 500 ppm, 2 / 5 strokes.

What is the OSHA exposure limit for Alcohol? OSHA PEL TWA 1000 ppm (1900 mg/m³); NIOSH REL TWA 1000 ppm (1900 mg/m³); IDLH 3300 ppm [10%LEL] (NIOSH Pocket Guide).

Which pump reads Draeger Alcohol tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Alcohol tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.