Draeger Ammonia Detector Tubes

6 Draeger short-term detector tubes for Ammonia, measuring ranges from 0.25 to 3 ppm up to 0.5 to 10 Vol%. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (pp. 126–312); prices are live. Ships in 1–2 business days.

Every Draeger tube for Ammonia

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
8101711Draeger Ammonia 0.25/a Detector Tubes, Box of 100.25 to 3 ppm10approx. 1 minyellow → blueBox of 10$92.11
6733231Draeger Ammonia 2/a Detector Tubes, Box of 102 to 30 ppm5approx. 1 minyellow → blueBox of 10$94.22
8101941Draeger Ammonia 5/b Detector Tubes, Box of 105 to 100 ppm1approx. 10 syellow → blueBox of 10$125.24
CH20501Draeger Ammonia 5/a Detector Tubes, Box of 105 to 70 ppm / 50 to 700 ppm10 /1approx. 60 s / approx. 10 syellow → blueBox of 10$129.45
8101301Draeger Ammonia 20/a-D Detector Tubes, Box of 1020-1,500 ppm in 1 h (down to 2.5-200 ppm in 8 h)yellow → blueBox of 10$151.01
CH31901Draeger Ammonia 0.5%/a Detector Tubes, Box of 100.5 to 10 Vol%1 + 1 desorption strokeapprox. 20 s/strokeyellow → purpleBox of 10$129.97

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), pp. 126–312, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Draeger MicroTubes for Ammonia (X-act 7000)

MicroTubeMeasuring rangePrice
Draeger Ammonia MicroTubes for X-act 70001-100 ppm; 100-2500 ppm$117.81

MicroTubes are read electronically on the Draeger X-act 7000, not on a hand pump.

Ammonia exposure limits

LimitValue
OSHA PELTWA 50 ppm (35 mg/m³)
NIOSH RELTWA 25 ppm (18 mg/m³) ST 35 ppm (27 mg/m³)
NIOSH IDLH300 ppm
CAS number7664-41-7
FormulaNH₃
Other namesAnhydrous ammonia, Aqua ammonia, Aqueous ammonia [Note: Often used in an aqueous solution.]
Conversion1 ppm = 0.70 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Ammonia (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless gas with a pungent, suffocating odor. [Note: Shipped as a liquefied compressed gas. Easily liquefied under pressure.]

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Ammonia tube questions

Which Draeger tubes measure Ammonia? 8101711 (0.25 to 3 ppm), 6733231 (2 to 30 ppm), 8101941 (5 to 100 ppm), CH20501 (5 to 70 ppm / 50 to 700 ppm), 8101301 (20-1,500 ppm in 1 h (down to 2.5-200 ppm in 8 h)), CH31901 (0.5 to 10 Vol%).

What is the lowest range Draeger tube for Ammonia? 8101711, 0.25 to 3 ppm, 10 strokes.

What is the OSHA exposure limit for Ammonia? OSHA PEL TWA 50 ppm (35 mg/m³); NIOSH REL TWA 25 ppm (18 mg/m³) ST 35 ppm (27 mg/m³); IDLH 300 ppm (NIOSH Pocket Guide).

Which pump reads Draeger Ammonia tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Ammonia tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.